Grid-I nt er ac tive GTFX AND GVFX INVERTER/CHARGER P rog raming Manual.
W AR R A N T Y S U M MA R Y Dear OutBack Customer , Thank you f or your purchase of OutBack pr oducts. W e make ever y eor t to assure our pow er conversion pr oducts will give you long and reliable service for your r enewable energy system.
2 T ABLE OF C ONTENTS W arranty Summar y.................................................................................................................................................................................. 1 Certicate of Compliance....
OUTBACK GTFX AND GVFX CERTIFICA TE OF C OMPLIANCE TO UL1 7 41 UTILIT YINTERAC TIVE INVERTERS OutBack GTFX and GVFX inverters comply with UL1741 for utility-interactive inverters. The follo wing specications ref er to expor ting power to a simulat ed utility source of less than 1% voltage total harmonic distor tion ( THD).
WEL C OME TO THE OUTBA CK POWER SYSTEMS FX SERIES INVERTER/CHARGER SYSTEM The FX Series Inver ter/Charger oers a complet e power conv ersion system—DC to AC, battery charging , and an AC T ransfer Switch—and can be used for stand-alone or back -up applications.
GRIDINTERAC TIVE FX SERIES INVERTER/CHARGER PR OGRAMMING NOT E: Please see the FX and VFX Series Inver ter/Charger Installation Manua l to install, wir e, and connect each FX Series I nverter/Charger . This programming manual assumes all FXs have been installed and ar e ready to pr ogram according t o the way they were wir ed.
The FX connected to P or t 01 is always programmed as the Master . AC Breakers O DC Breakers O Components and C onnections: 1. With all AC and DC breakers OFF , connect all FXs to the HUB with individual lengths of CA T5 cable.
AC Breakers O DC Breakers On 2. With the FXs connec ted to the HUB, turn only the DC br eakers ON and power up the components. All AC breakers should be OFF . NOT E: Powering up the FXs can cause the r ed ERROR ST A TUS light to blink. Af ter 5-10 seconds, the g reen INVERTER light should be bright and the ERR OR and AC IN lights dark.
3. After powering up the components, connect the MA TE to the HUB. a) Plug the MA TE into the 1st MA TE Port on the HUB. b) The MA TE will power up and should recognize an y component connected to the HUB.
ST ACKING OPTIONS OutBack Grid-Interac tive FXs can be stacked in Classic Series only. CLASSIC ST ACKING • T wo FXs are wired to two 120 V AC output legs producing 240 V AC between them. • Each FX powers one leg and acts independently of the other , but both combine when 240 V AC is required f or a load.
Once the MA TE recogniz es each FX (and OutBack Charge Controller), push and hold the rst two soft keys simultaneously to return to the MAIN menu . T o program the FXs , go to the ADV/FX/ST ACK menu on the MA TE navigating with the follo wing steps: • Pr ess the <ADV> soft key.
A DV choose device: FX CC D C MA TE ADV/FX/P A GE 1---------------- choose catego r y : ADV INV CH GR PG2 • On the ADV/FX/P AGE 1 screen, press the <PG2> soft key and go to the AD V/FX/P AGE2 screen. • In the ADV menu, press the <FX> soft ke y .
ADV/FX/S T ACK--------P01 stack Ma ster phase DOWN INC DEC PO R T • Stacking the FX I nverter/Chargers begins on this screen. See specic stacking procedures in the next section. ADV/FX/S T ACK----------P01 stack Ma ster phase DOWN INC DEC PO R T • P or t 01 always takes the Master FX.
MASTER With the P or t 01 FX as the M aster , press the <PORT> soft key to change the remaining P or ts and designate the r emaining FXs as Slaves.
POWER SA VE LE VELS Depending on the model, each FX consumes 20-25 watts of power when it r emains on, even if it isn ’t actively inverting or charging. OutBack o ers a power save featur e for its non- grid-interactive systems, but is not available for g rid-interactive systems.
AC ON • With the programming completed, turn the AC output breakers ON with the AC BYP ASS on the AC breaker panel switched to NORM AL. V erify the AC voltage output through the M A TE following path: P A TH MAIN------- SETUP ------------ ST A TUS/FX/P AGE1---------- Float P00 ST A TUS/FX/METER--P00 12.
If the FX’ s AC source is available, the y ellow AC IN ST A TUS light will blink . The FX will connect to the utility grid when the voltage is within 108-140 V AC and the frequency between 59.3-60.5 H z. After about 30 seconds, the AC IN light should st op blink ing and stay lit.
A UXILIARY A UX FUNC TIONS The A UX output provides a 12 VDC, 0.7 ADC max output at the AUX t erminals to control either DC or AC external loads.
• The screen displays <132>. P ress the <INC> button until it scrolls to the passwor d 141. ADV/P ASSW ORD-------------- ent er the passwor d 132 ENTER INC DEC EXIT ADV/P ASSW ORD-------.
ADV/FX/PG2--------------------- choose catego r y : PG1 GRID GEN PG3 • Pr ess the <PG3> soft key which leads to the AD V/ FX/P AGE3 screen. ADV/FX/P A GE3----------------- choose catego r y : PG2 A UX ST ACK PG4 • On the ADV/FX/P AGE3 screen, press the <A UX> soft key to adjust the AUX output set points and operation.
LIST OF A UX FUNC TIONS • Cool F an activates the standard T ur boF an which cools the FX. • Divert DC and Divert AC allows the A UX to diver t excess renewable energy t o a DC or AC load, respectively . This allows control of ener gy sources such as wind turbines or hydr o- generators.
ADV/FX/A UX---------------P00 genalert 11.5vdc on setpoin t DOWN INC DEC PO R T • F rom the Remote aux output function screen, press the <DOWN> soft key. This will bring up the rst of several screen used to adjust which ever mode y ou have chosen f or the AUX function.
• If a ventilation fan is only needed intermittently , the ventfan o period shuts the fan o for a user - determined time before starting up again for a one- minute period when the battery voltage exceeds the ventfan on setpoint.
BA T TERY CHARGING INSTRUC TIONS Keeping your batter y bank energized is v er y impor tant. Although a batter y bank can last for many years if properly cared f or , it can also be ruined in a shor t period of time if neglected.
13.6 14.4 14.4 u 12.5 10.5 12.5 13.0 14 11 11 13 14.6 1.0 hours 1.0 hours 1.0 hours 60 cycles* *20 for G rid-Tie 6 108 208 140 270 .5 min USE A UTO COOL F AN 4 min 9 min 5 min 108 208 140 270 6 A UTO .
W A R R A N T Y OutBack P ower Sy stems T wo Y ear Limited Warran ty OutBack P ower Systems Inc. war rants that the products it manufactures will be free from def ec ts in materials and work manship for a period of two (2) years subject to the conditions set forth below .
PRODUC T REGISTRA TION Y our purchase of an OutBack P ower Systems product is an important investment. Registering your products will help us maintain the standard of excellence y ou expect from us in terms of per formance, quality and reliability . Please take a moment t o register and provide us with some important information.
1 0Y EAR LIMITED W ARRANT Y (Calif ornia) GTFX, GVFX and PS1 Pr oducts OutBack P ower Systems , Inc. (“OutBack ”) provides a ten-year (10) limit ed warranty (“ Warranty ”) against defects i.
1. Pr oof- of-purchase in the form of a copy of the original P roduct purchase invoice or r eceipt conr ming the Pr oduct model number and serial number ; 2. OutBack issued 10-year warranty cer ticate; 3. Description of the problem; and 4. Shipping address f or the repaired or r eplacement equipment.
10- Y ear W arr anty Registra tion for GVFX, GTFX and PS1-California 1 0YEAR W ARRANT Y REGISTRA TION CALIFORNIA T o request a 10-y ear Limited W arranty ; complete this form along with a check or money order in the amount of $599 USD pay able to OutBack Po wer Syst ems, Inc.
30.
European Sales Oce Barcelona, ESP AÑA (+34) 600.843.845 19009 62nd Avenue NE Arlington, W A 98223 USA (+1) 360.435.6030 www.outbackpower .com 900-0087-01-00 REV A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Outback Power Systems GTFX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Outback Power Systems GTFX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Outback Power Systems GTFX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Outback Power Systems GTFX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Outback Power Systems GTFX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Outback Power Systems GTFX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Outback Power Systems GTFX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Outback Power Systems GTFX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.