Manuale d’uso / di manutenzione del prodotto RM622PA del fabbricante Oregon Scientific
Vai alla pagina of 12
1 EN CONTENTS Introduction ............................................................. 2 Product Overview ................................................... 2 Front View ......................................................... 2 Back View ........
2 EN PRODUCT OVERVIEW FRONT VIEW 1. SNOOZE / LIGHT button 2. UP and DOWN keys 3. MODE button 4. ZONE button 5. ALARM button 6. Swivel projection 7. LCD display INTRODUCTION Thank you for selecting the Oregon Scientific TM Atomic Projection Clock (RM622PA).
3 EN BACK VIEW 1. FOCUS knob 2. IMAGE ROTATION knob 3. Power adaptor socket 4. Battery compartment 5. PROJECTION ON switch 6. Table stand 7. RESET hole 1 2 3 4 5 6 7 LCD DISPLAY 1. Clock hour and minute 2. Radio frequency (RF) signal reception 3. Alarm on icon 4.
4 EN AC ADAPTOR The main unit has a 3.0V AC/DC adaptor with jack, which provides continuous clock projection. CLOCK The clock automatically synchronizes the current time and date when it is brought within range of the WWVB- 60 radio signal (60 kHz) generated from Fort Collins, Colorado.
5 EN ACTIVATING / DEACTIVATING THE RF SIGNAL 1. To activate the RF signal, press and hold for 2 seconds. 2 . To deactivate the RF clock reception, press and hold ZONE for 2 seconds. NOTE The RF signal icon appears on the LCD when it is activated and disappears when it is deactivated.
6 EN When the Snooze function is enabled, the Snooze period will last 8 minutes before the alarm sounds again. will flash coninuously on the LCD. NOTE Pressing SNOOZE / LIGHT turns on the green LED backlight that lasts for 5 seconds before automatically turning off.
7 EN NOTE If the unit is being run on batteries, the PROJECTION ON / OFF switch does not need to be on. If you press SNOOZE / LIGHT , the projection light will turn on anyway. ADJUSTING THE PROJECTOR The RM622PA allows you to adjust the projector so that you are able to view the projection image with more clarity and convenience.
8 EN TROUBLESHOOTING PROBLEM SYMPTOM REMEDY Calendar Illegible month / Change language date Clock Cannot adjust Disable atomic clock clock Cannot auto- 1.
9 EN Resolution: 0.2 ° F (0.1 ° C) CLOCK RF Clock: Auto or manual (disabled) Clock display: HH:MM:SS Hour format: 12hr AM/PM Calendar: MM/DD; weekday in 3 languages (English, Spanish, French) Alarm: Single alarm with 2-minute crescendo POWER Main unit batteries: 2 x AA (UM-3) 1.
10 EN FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
11 EN © 2004 Oregon Scientific. All rights reserved. P/N: 086-003592-018.
12 EN Atomic Projection Clock Model: RM622P A User Manual.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Oregon Scientific RM622PA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Oregon Scientific RM622PA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Oregon Scientific RM622PA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Oregon Scientific RM622PA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Oregon Scientific RM622PA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Oregon Scientific RM622PA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Oregon Scientific RM622PA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Oregon Scientific RM622PA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.