Manuale d’uso / di manutenzione del prodotto WMS-16 del fabbricante Omega
Vai alla pagina of 23
www .omega.com e-mail: info@omega.com omega.com ® ® U ser ’ s Guide WMS-16 Complete W eather Station Shop online at.
WMS-16 Weather Station Operator’ s Manual 1 INT RODUC TION Congrat ulation s on you r purchas e of a WMS- 16 Weather Station, and welcome to the world of modular, user friendly weather data collection.
WMS-16 Weather Station Operator’ s Manual 2 Barometric Pressure Barometric pres sure is sensed us ing a piezoresist ive sensing element. This element responds to chan ges in baro metric pressure w ith a correspondin g change in res istance.
WMS-16 Weather Station Operator’ s Manual 3 INSTALLATION Instal lation of the WMS-16 i s sim p le and straig ht forward, thanks t o its m odular design and termin al-strip conn ections. Figure 1 shows the control module’s rear pan el and the locations of the various connections.
WMS-16 Weather Station Operator’ s Manual 4 Tripod T ower The fiv e foot tripod tow er provided for th e WMS-16 is constructed o f steel tubing for durability and strengt h. Horizont al bracing is a f eature of the tripod t owe r. The tower’s foot brackets can be bolted on to a concrete foundat ion or a w ooden platf orm.
WMS-16 Weather Station Operator’ s Manual 5 Sensor Installation Install the sensors in their chosen locatio ns, bearing in mind the installation consideratio ns noted earlier. Run cables fro m the sensors to the control module location, with no cab le exceeding the maximum allow able length listed in Table 1.
WMS-16 Weather Station Operator’ s Manual 6 To set barometric pressure offset, for sea level, you must first obtain a reliable barometric pressure for your location. The barome tric pressu re range is 28.25 to 30. 75. This can be foun d by contacting the n earest airport or w eather service facility.
WMS-16 Weather Station Operator’ s Manual 7 OPERATION The WMS-16 Weather Station collects and logs data automatically, requiring little user input. Ultimate control, however, is prov ided by the int.
WMS-16 Weather Station Operator’ s Manual 8 averaging period is les s than the logging period the averag e logged will be for a period of time at the end of the logging period equal to th e averaging period.
WMS-16 Weather Station Operator’ s Manual 9 Figure 7 Row an d Column Pr esentati on of Cur rent Dat a Weather Tr ends The curr ent ob ser vatio ns te xt sc ree n disp lays se ver al weat her features in addition to the current sensor readings.
WMS-16 Weather Station Operator’ s Manual 10 not, hover, return to a previous screen, you must return to the main menu and begin the retrieval procedure anew . If you want to fu rther manipu late or obtain a printe d copy follow the procedure described in the Data Download section below.
11 If you want to fu rther manipu late or obtain a printe d copy follow the procedure described in the Data Download section below. Data Download Selection “5” on the main menu “D ata download” – allows you to s ave a perm anent record of th e WMS-16’s stored data.
WMS-16 Weather Station Operator’ s Manual 12 ALARMS There are six us er programmable alarm s on the WMS-16. They can be ass igned to either of tw o alar m switches. (ALARM 1 an d ALARM 2) w hich provide a sw itched connection to ground. Electrical con nection is made to the terminal strip at the positions labeled ALARM 1 and ALARM 2.
13 to always have DCD on . The modem is then plugg ed into a telephone line and it is ready to be called from a remote location. In order to call the WMS-16 f rom a remote computer the computer n eeds to have a com munications program su ch as HyperTermin al or Procom .
WMS-16 Weather Station Operator’ s Manual 14 Sensor type Model Input Calibration Wind Speed WS-01/02 P1 If you intend to add another sensor select A. If you do not want to add another sensor select Q. You will be asked if you ar e sure that you want to er ase memory.
15 From the Station Set Up menu press number 6. ADD OR R EMOVE SENSORS. Then press Y , then ENTER . From the Sensor Type Menu select number 4. Temperatu re. Then press ENTER. From the Temperature Sensors Menu s elect number 1. (WMS-16T). Then press ENT ER .
WMS-16 Weather Station Operator’ s Manual 16 From the Station Set Up menu press number 6. ADD OR R EMOVE SENSORS. Then press Y , then ENTER . From the Sensor Type menu select number 6. (Pressure). Then pr ess ENTER . From the Pressure Sensors menu select number 1.
17 The auxiliary temperature sensor is a thermistor attach ed to a two conductor c able. Connect one conductor to A5 terminal and the other conductor to a GROUND t erminal. INITIALIZATION OF THE AUXILIARY TEMPERATURE SENSOR. Press EXC to get the MAIN MENU.
WMS-16 Weather Station Operator’ s Manual 18 Then select Chann el A2. The Sensor Configura tion menu appears and it will show: SPECIFICA TION S DATA ACQUIS ITION M ODULE Reporting Units : English or.
19 Options : WMS- 16SR Solar Ra diatio n Sensor , i nclud es mount in g arm and 40' cable WMS-16T Auxiliary Air Temperature Sensor , 40’ Cable WMS-16TWS Water or Soil Temperature Sensor , 40’.
M3749/1001 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Co.
Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omega WMS-16 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omega WMS-16 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omega WMS-16 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omega WMS-16 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omega WMS-16, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omega WMS-16.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omega WMS-16. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omega WMS-16 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.