Manuale d’uso / di manutenzione del prodotto PTC900 del fabbricante Omega Vehicle Security
Vai alla pagina of 32
P P T T C C 9 9 0 0 0 0 / / P P T T C C 9 9 0 0 1 1 Panel -M M ount P P rogram mable Timer a a nd R R eal -T T ime C C lock omega.com e-mail: info@omega.
OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F A X: (203) 359-7700 e-mail: info@omega.
3 z 6-DIGIT 0.56" RED SUNLIGHT READABLE DISPLA Y z 4 SEP ARA TE DISPLA YS (Timer , Counter, Real-T ime Clock, and Date) z CYCLE COUNTING CAP ABILITY z PROGRAMMABLE FUNCTION KEYS/USER INPUTS z FOU.
4 General Meter S pecifications . . . . . . . . . . . . . 4 Optional Plug-In Cards and Accessories . . . . 5 Installing the Meter . . . . . . . . . . . . . . . . . . . . 6 Setting the Jumpers . . . . . . . . . . . . . . . . . . . 6 Installing Plug-In Cards .
5 O PTIONAL P LUG - IN C ARDS AND A CCESSORIES W ARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PTC900/PTC/901 series meters can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below .
6 Installation The meter meets NEMA 4X/IP65 requirements for indoor use when properly installed. The meter is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the meter . Slide the panel gasket over the rear of the meter to the back of the bezel.
7 3.0 I NSTALLING P LUG -I N C ARDS The Plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the meter . The Plug-in cards have many unique functions when used with the meters.
8 Before connecting the wires, the T imer Input logic jumper should be verified for proper position. 4.2 TIMER INPUT WIRING CAUTION : T imer Input common is NOT isolated from User Input common.
9 4.4 SETPOINT (ALARMS) WIRING SETPOINT PLUG-IN CARD TERMINALS SINKING OUTPUT LOGIC CARD SOURCING OUTPUT LOGIC CARD 4.5 SERIAL COMMUNICA TION WIRING RS232 Communications RS232 is intended to allow two devices to communicate over distances up to 50 feet.
10 T ime synchronization between multiple PTC901 meters can be accomplished through a hardware interface on the Real-T ime Clock option card. This RS485 type interface allows connection of up to 32 PTC901 meters in a two-wire multidrop network, at distances up to 4000 ft.
11 PROGRAMMING MODE ENTR Y (P AR KEY) The Programming Mode is entered by pressing the PA R key . If this mode is not accessible, then meter programming is locked by either a security code or a hardware lock. (See Modules 2 and 3 for programming lock-out details.
12 This parameter determines how the T imer Input Signals affect the “Run/Stop” status of the T imer . The timing diagrams below reflect a Sinking input setup (active low). A Sourcing input setup (active high) is available through plug jumper selection (see Section 2.
13 ª « ª « NO FUNCTION W ith this selection, NO function is performed. This is the factory setting for all user inputs and function keys except the Reset ( RST ) Key . PROGRAMMING MODE LOCK-OUT Programming Mode is locked-out, as long as activated (maintained action).
14 ª « ª « DISPLA Y HOLD and RESET (Edge T riggered Reset) When activated, the meter “freezes” the display values entered as in the sublist, before performing an internal Momentary Reset on the selected displays.
15 When active (maintained action), the meter “holds” (maintains) the present output state for all Setpoints entered as in the sublist. Does not apply to Output Set and Reset User Inputs. Program only one user input for this function. Note : The r emaining parameters only appear when a Setpoint Car d is installed in the meter .
16 6.3 MODULE 3 - D ISPLAY AND P ROGRAM L OCK - OUT P ARAMETERS ( ) Module 3 is the programming module for setting the Display Lock-out Parameters and the “Quick Programming Mode” V alue Access Parameters.
17 6.4 MODULE 4 - C YCLE C OUNTER P ARAMETERS ( ) P ARAMETER MENU Module 4 is the programming module for the Cycle Counter Parameters. In the Display Mode, the CNT annunciator indicates the Cycle Counter display is currently being shown.
18 Timing Diagrams for Predefined Timer Operating Modes NOTE : Input A is shown as a Sourcing input (active high). If a Sinking input (active low) is used, the logic levels for Input A would be inverted.
19 ª « SETPOINT ACTION This parameter determines the mode for output deactivation as shown below . Output activation is controlled by the SETPOINT ON parameter setting. The and selections are not available when Setpoint is assigned to .
20 DISPLA Y DESCRIPTION F ACTOR Y Sunday Monday Saturday Friday Thursday Wednesday T uesday .
21 6.7 MODULE 7 - S ERIAL C OMMUNICATIONS P ARAMETERS ( ) P ARAMETER MENU This module can only be accessed if a Serial Communications Card is installed. * Only appears if the Real-Time Clock Card is installed. Module 7 is the programming module for the Serial Communications Parameters.
22 SENDING SERIAL COMMANDS AND DA T A When sending commands to the meter , a string containing at least one command character must be constructed. A command string consists of a command character , a value identifier , numerical data (if writing data to the meter) followed by the command terminator character * or $.
23 Abbreviated T ransmission ( = ) ✰ These characters only appear in the last line of a block print. The abbreviated response suppresses the address and register mnemonics, leaving only the numeric part of the response. Note : T ransmissions are formatted to match the way the parameter is displayed.
24 Module 8 is the programming module for the Real-Time Clock (R TC) Date and T ime Parameters. In the Display Mode, the DA T annunciator indicates the R TC Date is currently being shown. The R TC T ime display is shown with no annunciator . This programming module can only be accessed if a Real-T ime Clock card is installed.
25 TIME DISPLA Y FORMA T ª « DA TE DISPLA Y FORMA T AUTO CHANGE FOR DA YLIGHT SA VINGS TIME Select the format in which the Real-T ime Clock T ime will be displayed. The format selections depict the range for the R TC T ime display , and DO NOT represent the curr ent R TC Time.
26 P ARAMETER MENU RESTORE F ACTOR Y DEF AUL TS Use the RST and/or arrow keys to display and press PA R . The meter will display and then returns to . Press DSP key to return to the Display Mode.
27 5-OPEr Timer Operating Modes DISPLA Y PARAMETER USER SETTING F ACTOR Y SETTING USEr-1 USER INPUT 1 NO USEr-2 USER INPUT 2 NO USEr-3 USER INPUT 3 NO F1 FUNCTION KEY 1 NO F2 FUNCTION KEY 2 NO rSt RES.
28 7-SrL Serial Communication Parameters DISPLA Y P ARAMETER F ACTOR Y SETTING USER SETTING bAUd BAUD RA TE 9600 dAtA DA T A BITS 7 PAr P ARITY BIT Odd Addr METER UNIT ADDRESS 00 Abbr ABBREVIA TED PRI.
29 T imer Ra.
30 P ART N UMBER I NFORMATION ACCESSORIES PTC9-RTC00 DP6-CDC4C Real-T ime Clock card Real-T ime Clock Extended MODBUS communications output card with dual RJ1 1 connectors DP6-CDC40 MODBUS communicati.
W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time.
Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels &.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omega Vehicle Security PTC900 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omega Vehicle Security PTC900 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omega Vehicle Security PTC900 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omega Vehicle Security PTC900 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omega Vehicle Security PTC900, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omega Vehicle Security PTC900.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omega Vehicle Security PTC900. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omega Vehicle Security PTC900 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.