OM-DAQ-USB-2401 Multiple Channel USB Data Acquisition Module e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at omega.com ® U ser ’ s Guide ®.
Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.
i OM-DAQ-USB-2400 Multiple Channel USB Data Acquisition Module TABLE OF CONTENTS Page Section 1 - Introduction ....................................................................... 1-1 1.1 Precautions ................................................
ii OM-DAQ-USB-2400 Multiple Channel USB Data Acquisition Module TABLE OF CONTENTS Page 5.4 T riggering ................................................................................................... 5-4 5.5 Signal Modes ...........................
iii List of Figures Section Figure Description .............................................................. Page Section 1 1-1 IEC Symbols ............................................................... 1-2 1-2 System Components ....................
iv List of Figures Section Figure Description ............................................................. Page 4-25 OM-DAQ-USB-2400 Block Diagram .................... 4-14 4- 26 OM-DAQ-USB-2401 Single-ended and Differ ential Conections to Analog Input Channels Diagram .
Section 1 - Intr oduction Please read this manual completely befor e installing and operating your Omega data acquisition system. It’s important to read and follow all notes, cautions, warnings and safety precautions befor e operating this device. “Device” refers to your data acquisition unit.
When using OM-DAQ-USB-2401 unit to acquire data, computer energy save modes can cause false data readings. Prior to using the unit, ensure your computer’ s energy save mode is disabled. If needed, consult your PC user’ s manual to disable energy save (power suspension) modes.
*At highest scan rate, 1000 samples/sec +/- 1% with one channel on, +/- 5% with all channels on. The main items you will be using in your data acquisition system are the OM-DAQ-USB-2401 unit, its USB cable, and power adaptor .
Section 2 - Hardware It is important that you read this manual completely and follow all safety precautions befor e operating this instrument. 2.1 Package Inspection Remove the packing list and verify that you have received all your equipment.
Section 3 - Hardware Setup 3.1 OM-DAQ-USB-2401 System Components Figure 3-1. OM-DAQ-USB-2401 Hardware and Dimensions The external power por t is used in applications which have USB hubs that are not self-powered. See the next section for more information.
3.2.1 USB-powered Hubs These hubs draw all power from the host USB connector ’s power pins. The power is used for hub internal functions and for the hub’s ports.
3.3 Connecting Y our OM-DAQ-USB-2401 Acquisition System to PC When using a power adaptor with your DAQ system, be sure to supply power (from the adaptor to the DAQ) before connecting the USB cable. This allows your DAQ to inform the host computer (upon connection of the USB cable) that the unit requires minimal power from the computer .
3.4 Connecting V arious Hardware Setups ON-DAQ-USB-2401 data acquisition systems range from simple to complex. One example of a simple system is that of one OM-DAQ-USB-2401 connected to a PC’s USB connector . A much more complex system is one that contains 10 OM- DAQ-USB-2401 units and a combination of USB-powered and self-power ed hubs.
3.4.2 Connection to USB-powered Hub In this example, two OM-DAQ-USB-2401s are connected by cable to individual ports of a single USB-powered hub. Since the hub r eceives all its power from the computer ’s USB, the hub cannot supply adequate power to the DAQ units.
Figure 3-5. Connections to Self-Powered Hub and to USB-Powered Hub USB port locations var y from PC to PC. 3.5 OM-DAQ-USB-2401 Mounting The OM-DAQ-USB-2401 mounting kit contains the following accessor.
3.5.1 OM-DAQ-USB-2401 W all Mounting In order to mount the OM-DAQ-USB-2401 to the wall, you will need to: 1. Remove the rear scr ews from the OM-DAQ-USB-2401. 2. Align the mounting brackets with the rear holes on the DAQ unit (make sur e that the ears are facing outwar ds, like in the figure below).
Hardware Setup 3 3-8 3.5.2 OM-DAQ-USB-2401 DIN Rail Mounting In order to mount the OM-DAQ-USB-2401 to a DIN-Rail, you will need to: 1. Attach the DIN-rail plastic adaptors to the mounting brackets, using the four shorter screws. 2. Remove the rear scr ews from the OM-DAQ-USB-2401.
4-1 Software 4 Section 4 - Software 4.1 Getting Started The following program files ar e included on the Omega DAQ Central User Software CD supplied with your data acquisition unit. These files can also be downloaded from the omega.com website should you misplace your CD.
Software 4 4-2 4.2.2 Software Setup Insert the DAQ Central Software CD that was included with your DAQ unit into the CD-ROM drive on your PC. Y our system should begin the installation process automatically .
Software 4 4-3 Figure 4-3. Confirm Installation Screen The setup wizard now has all the information to complete the installation of the software on your PC. T o continue with installing the program click the “Next >” button. During the install process, a W indows Command Prompt may pop up.
Software 4 4-4 4.3 DAQ Central Software Operation Below is the basic flow of operation when using the software: 1. Highlight desired device. 2. Open Device Configuration window . 3. Set channels, sample rate, triggering, and data output file. 4. Click “OK” to confirm Device Configuration.
TOOLBAR BUTTONS Start Button Initiates data acquisition for the highlighted device. Even if a Start T rigger is set, this must be pressed to Arm the device. Stop Button Stops data acquisition for the highlighted device. If a Stop T rigger is set, this will cancel the trigger .
4.3.1 Main Control W indow Pull-Down Operations Below are the operations that ar e available in the Pull-Down Menus of the DAQ Central Main Control W indow .
Figure 4-7. Tools Menu Export Data File – T o conver t data file from binar y file to .csv file Fgure 4-8. Help Menu Check for Updates T o check for the latest Omega DAQ Central software update information through the Internet connection. About T o view software version.
Section 4.3.2 Device Configuration The Device Configuration window contains the Channel, T riggers, and Data tabs. Details for these tabs are below . When finished making changes, press “OK” to confirm the changes or “Cancel” to abandon the changes.
Configuration Parameter Settings Channel The input channel’ s name (not editable) AN1D = analog channel 1, differential input AN1H = analog channel 1, single-ended high input AN1L = analog channel 1, single-ended low input Etc. Nickname Y ou can specify the Nickname (e.
Figure 4-13. Trigger Options The T riggers tab is used to set up triggers for starting and stopping data acquisition. The Start T rigger and the Stop T rigger each have a differ ent set of available trigger types: Figure 4-14. "Start Trigger" Options Figure 4-15.
For all Start T rigger types, the device must be armed by pushing the Star t Button on the main window . Data storage and display will not begin until the device triggers. Data T ab Figure 4-16. Data Tab T o save data to a file on the PC, select the Data tab and choose a filename.
Software 4 4-12 Figure 4-18. Main Window Screen Figure 4-19. Gauges Screen Figure 4-20. Bars Screen Figure 4-21. Digital Screen Figure 4-22. Table Screen.
Figure 4-23. Waveform Screen Each Data Display can be customized by clicking the Options Icon . Each Data Display's Options screen lets you choose which device channels to display in that window . Channels can be added or removed with the Add Display and Delete Display buttons.
Software 4 4-14 4.4 Power Line Rejection The OM-DAQ-USB-2401 Series can take readings while making use of 50/60Hz line cycle rejection. While in the line cycle r ejection mode, the maximum sample rate is as follows: • 50 Hz rejection: Scan Rate (SR) Range: 0.
The converter is comprised of a 4th-order , delta-sigma ( Δ∑ ) analog-to-digital (A/D) converter modulator followed by a programmable digital filter . A flexible input multiplexer handles differ ential or single-ended signals; the programmable filter allows the user to optimize between a resolution of up to 23 bits noise-fr ee.
In DAQ applications, thermocouples should not be connected single-ended. Doing so can result in noise and false readings. This is especially true when acquiring other high-amplitude signals in conjunction with thermocouple signals that are connected single-ended.
Resolution (Effective Number of Bits - ENOB, RMS) – The number of r eliable data bits that exist for a signal’s measurement. The gr eater the resolution, the more detailed the r eading. For example, with an increased r esolution, a reading of 5.12 V could become 5.
4.11 Thermocouple Measurements The OM-DAQ-USB-2401 provides ef fortless thermocouple (TC) measurements. The unit includes built-in cold-junction compensation (CJC), which is automatically invoked when you select TC measurements. The DAQ unit automatically converts acquired voltage r eadings into compensated-linearized temperature r eadings.
Section 5 – Signal Management 5.1 Channel Control and Expansion In the OM-DAQ-USB-2401 system, the quantities and types of DAQ units used determine the system’s channel capacity . Up to 10 OM-DAQ-USB-2401s can be used with one host PC. See the Specifications for more detailed channel information.
Scan Rate vs. Resolution 2 Resolution Scan Rate 3,4 (Scans (ENOB 5 Speed Designation Scan Time 1 (s) per Second - SPS) RMS) V er y Slow , 50 / 60 Hz rejection 3600s>=ST >= 6.5s 0.0002778=< SR <= 22.5 0.153 Slow , 50 Hz rejection 6.5s> ST >= 1s 0.
The following table provides general advice r egarding the selection of Scan T ime. The concepts are further illustrated by the figur e, Examples of Under Sampling. Scan Time (Measurement Scan Rate Analog Input Signal Duration) (Sample Rate) Resolution Steady , or gradual change Long Low High Highly variable (unsteady) Short High Low Figure 5-1.
5.4 T riggering T riggering controls an acquisition cycle. Once the system is armed, a trigger is requir ed to collect the data. The user must determine the triggering requir ement based on the nature of the measurement and the amount of data needed to satisfy the system’s purpose.
Differential mode r efers to a mode, or circuit set-up, in which a voltage is measured between two signal lines. The measur ed differ ential voltage is used for a single channel. An advantage of using differ ential inputs is that they reduce signal errors and the induction of noise r esulting from gr ound current.
Resolution: An analog-to-digital converter (ADC) converts an analog voltage to a digital number . The digital number represents the input voltage in discr ete steps with finite resolution. ADC resolution is determined by the number of bits that repr esent the digital number .
5.9 Input and Source Impedance As illustrated below , the input impedance (Ri) of an analog-to-digital converter combines with the transducer ’s source impedance (Rs) forming a voltage divider . This divider distorts the voltage being read at the analog-to-digital converter .
Section 6 - CE Conformity 6.1 OM-DAQ-USB-2401 Design for CE Conformity The OM-DAQ-USB-2401 has been designed to meet requir ements as outlined in European Community EMC Dir ective EN61326. Three ferrite cor es are included in the OM-DAQ-USB-2401 package.
Figure 6-2 Ferrite Core The ferrite cores may be r emoved from the DAQ unit; however , in order to conform to CE standards, all of the ferrite cor es must be attached to the USB cable and power adapter . If the user is not using the power adapter but relying on power from the host USB connection, no ferrites are required.
Section 7 – T roubleshooting 7.1 Basic Checklist Power – Check USB cable connection. The green “PWR IND” LED should be lit on the DAQ device. If using a powered USB hub, make sur e its power cable is plugged in. Signal – Check signal lines and connections.
Section 8 – Ser vice & Calibration Y our Omega DAQ components have been built and factory calibrated to meet or exceed the specifications listed here in this manual. The following section provides information on how to have your device serviced.
Section 9 – Specifications General Isolation: 500V from PC External Excitation Output V oltage: +12v DC Regulated, Maximum total current output 67mA Power Requirements: Powered from USB port max 500 mA, or from external 7.5 to 12 Vdc, (1.0 A recommended) Thermocouple T ypes: J, K, T , E, R, S, B, N Cold-Junction Compensation Accuracy: ±1.
Thermocouple Input Range: T ype J: -18 to 1200°C (0 to 2192°F) T ype K: -129 to 1372°C (-200 to 2502°F) T ype T : -101 to 400°C (-150 to 752°F) T ype E: -184 to 1000°C (-300 to 1832°F) T ype R.
T able 9-1. Thermocouple Accuracy (ºC) for OM-DAQ-USB-2401 TC T ype T emp. T ypical Fast (°C) Slow -18 1.3 3.8 J0 1 . 1 3 1200 0.9 2.5 -129 1.8 5 K0 1 . 4 3 . 9 1372 1.3 3.7 -101 1.6 4.5 T0 1 . 4 4 400 1 2.9 -184 1.2 3.4 E0 0 . 9 2 . 6 1000 0.7 1.9 204 5.
10.1 International Usage & CE Marking The OM-DAQ-USB-2401 multiple channel USB data acquisition module is CE marked and certified for use in several European countries. Please contact OMEGA for information on International Regulatory Compliance for each country .
NOTES: 10-2.
NOTES: 10-3.
NOTES: 10-4.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f pu rcha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M5025/01 12 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Co.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omega Engineering OM-DAQ-USB-2401 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omega Engineering OM-DAQ-USB-2401 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omega Engineering OM-DAQ-USB-2401 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omega Engineering OM-DAQ-USB-2401 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omega Engineering OM-DAQ-USB-2401, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omega Engineering OM-DAQ-USB-2401.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omega Engineering OM-DAQ-USB-2401. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omega Engineering OM-DAQ-USB-2401 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.