Manuale d’uso / di manutenzione del prodotto RACKMUX-T15 del fabbricante Network Technologies
Vai alla pagina of 55
MAN029 Rev Date 10/1 8 /2007 RACKMUX-T15 Rack Mount ANSI Terminal Drawer Installation and Operation Manual RACKMUX ® Series NETWORK TECHNOLOGI ES INCORPORATE D Te l:33 0-5 62 -70 70 Fax :33 0-5 6 2-1 999 1275 D an ner Dr Aurora, OH 44202 www.netwo rkt ec hinc.
i TRADEMARK RACKMUX is a registered trademark of Net work T e chn ologies Inc in the U.S. and other countries COPYRIGHT Copyright © 2004 , 2007 by Network Techno lo gies Inc.
ii TABLE OF CONTENTS Introduction ................................................................................................................... ................................................... 1 Materials .....................................
iii TABLE OF FIGURES Figure 1- Mount RA CKMUX to rack ................................................................................................ ................................................... 4 Figure 2- Position RACKMU X with clear ance to open .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 1 INTRODUCTION The RACKMUX-T15 (formerly referred to as RACKMUX-T ERMINAL ) Ra ck Mount ANSI Terminal Drawer (RACKMUX) places a VTxx/ANSI Terminal right in the rack for space-saving, conv enient control of SUN or PC-based headless servers.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 2 Options • LCD anti-glare protective glass shiel d - add a "G" to the model when ordering (i.e. RACKMUX-T15 G ) • Telco 2-post style mounting kit- order RL-T 15-TEL • DC Power option- for use with 36-72VDC i n put- add “48V” to the part number (i.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 3 FEA TURES AND FUNCTIONS 1. Power Button- press to turn the LCD monitor ON and OFF 2. Power LED - indicates operation status Green=Power-On, Video Input Signal OK Red = Suspend / Stand-by, or no Video Input Signal 3.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 4 1. INST ALLA TION 1.1 Rack Mounting Instructions 1.1.1 Standard Rack The RACKMUX was designed to be mounte d to a rack and incl udes mounting flanges to make attachment easy. 1. Determine the mounting height in the ra ck for the drawer.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 5 1.1.2 Optional Telc o 2-Post Mounting If the Telco 2-post mounting bracket kit (RL-T15-TEL ) is to be used, sec ure the short and l ong brackets to each side of the drawer as shown in Fig. 3. Apply 2 nuts (supplied) per bracket to se cure the brackets to the drawer.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 6 SUB D 25 male con ne cto r Re ar V iew RACKMUX-T 15 Attach lo cal printe r eit h er b y par all el ca ble to Par all el or by ser ial c able t o Ser ial .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 7 1.3 Power Up The Terminal 1. Plug in to power ON the RACKMUX. 2. Using the key, unlock the drawer and slid e the keyboard and LCD Disp lay out far enough to raise the display to a comfortable viewing angle.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 8 2.1.4 Default Configuration The terminal is delivered pr e-configured with the following setti ngs suitable for most RS232 serial consol e connections at 9600 baud using VT-100 em ulation.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 9 2.2 Changing The Operating Parameters To select one of the setup menus shown, press the indicat ed function key. - The screen for that menu appear s with the name high lighted. - The fields in the middle of the screen indic ate the parameters that can be changed in that menu.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 10 End of Line Wr ap causes the cursor to move to the start of the next lin e when additional characters are entered at the end of a line.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 11 ---------------------------------------------------------------------------------------------------- ------------------------------------------------- F.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 12 Table 2- Programmab le Keys Enhanced PC-Style Key board Enhanced PC-Style Key board F1 through F12 ENTER (Both ENTER keys are progr ammable) (UP ARROW) .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 13 ---------------------------------------------------------------------------------------------------- ------------------------------------------------- F.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 14 Table 4- Color Palettes Palette Display Attribute Foreground Color Background Color 0 Normal Reverse (or blank) *1 Intensity *2 Intensity *2 and reverse.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 15 Table 4- Color Palettes (Cont'd) Palette Display Attribute Foreground Color Background Color 6 Normal Reverse (or blank) *1 Intensity *2 Intensity .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 16 3. LOCAL KEYBOARD COMMANDS Table 5 lists local keyboard comman ds in th e terminal's native mode. Table 5- Local Key board Commands in Native Mode .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 17 4. CONNECTOR PIN ASSIGNMENT Table 6- Serial Port (Serial 1) Connector Pin Assignments (RS232C 9-pin connecto r) Pin Signal Mnemonic Direction 1 Data car.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 18 5. COMMAND GUIDE 5.1 Commands Supported in ASCII Personalities Table 5-1 lists all the ASCII commands recogniz ed by the t erminal. The native mode code for the command is given in the second column. (The native mode includes WY-32 5,W Y-120 an d WY-60.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 19 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) Command FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term ACK mode off.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 20 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term -Program function ke.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 21 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Display Memory/Split.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 22 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Graphics Charact ers.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 23 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Editing (Cont'd.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 24 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Print Functions Prin.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 25 5.2 Variable Values for Table 10 Commands answer Up to 20 characters to defin e ans werback message attr Display Attributes attr Display Attributes SPAC.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 26 Variable Values for Table 10 Commands (Cont'd) fcolor Foreground Color fcolor Foreground Color 1 Black 5 Red 2 Bue 6 Magenta 3 Green 7 Yellow 4 Cya.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 27 Variable Values for Table 10 Commands (Cont'd) length Multiple Length of Page G 1xlines Equa l to the nu mber of data lines H 2xlines Dou ble the number of data lines I *b 4xlines Four times the number of data lines *b Available only in WY-50+ p ersonality.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 28 Variable Values for Table 10 Commands (Cont'd) p1 Function Key p1 Function Key 1 F1 6 F 6 2 F2 7 F 7 3 F3 8 F 8 4 F4 9 F 8 5 F5 0 F 10 P2 Function Key 1 Remote 2 Local 3 Normal Page Page 0 page 0 In the 80 columns mode: There hav e 4 pa ges of display memory.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 29 Variable Values for Table 10 Commands (Cont'd) wnd/page Windo w or Page 0 Page 0 or upper window 1 Page 1 or lower window Word Data Word 0 7 bits 1.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 30 Supported VT100, VT220 and Console ANSI Commands, Con t'd Command FUNCTION VT100, VT220 Console AN SI 132-column display CSI ?3 h Same 80-column di.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 31 Supported VT100, VT220 and Console ANSI Commands (Con t'd) final Final characte r final Final character A Designating UK ANSI character set < De.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 32 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Values for “ Psn ” in table on page 56 Psn Color Psn Color Psn Color Psn Color 0 Black 4 Red 8 Gray 12 Lt. Red 1 Blue 5 Magenta 9 Lt.Blue 13 Lt.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 33 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Command FUNCTION VT100, VT220 Console AN SI Editing Functions (Cont 'd) Erase erasa.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 34 Supported VT100, VT220 and Console ANSI Commands, Con t'd kc Unshifted function key kc Unshifted function key 6 F1 38 F7 7 F2 39 F8 8 F3 40 F9 9 F4 41 F10 10 F5 43 F11 37 F6 44 F12 hc Hexadecimal representation of charact er string assigned to the function key.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 35 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Command FUNCTION VT100, VT220 Console AN SI Auxiliary Keypad Modes Auxiliary keypad nume.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 36 Supported VT100, VT220 and Console ANSI Commands, Con t'd Command FUNCTION VT100, VT220 Console AN SI Request keyboard status report CSI ? 26 n Sam.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 37 7. USING PRINTER SER VER IN ETHERNET TERMINAL Introduction There are two ways to send the print jobs to Ethernet Terminal for printing: 1) through LPD protocol, and 2) through TFTP protocol.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 38 Step 4. Make the dir ectory availabl e to LPD main process Basically, the method has the following three proce dures: 1) Assign the spooling daemo n as the ow ner of this directory. 2) Allow the spooling daem on to be able to read from or write to the directory.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 39 7.4 Setup for TFTP When working on the BSD UNIX system, run the setup procedur e under Setup for LPD on pa ge 34. Otherwise run the Setup for LPD omitting step 6. 7.5 TFTP Printing Before using TFTP p rinting, the Ethernet Termin al needs to be in stalle d completely by Setu p for TFTP on page 34 .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 40 8. ON-SCREEN DISPLA Y (OSD) 8.1 Standard Controls The RACKMUX LCD has 5 standard co ntrol buttons and a power LED. The 5 stand ard c ontrol buttons operate as follows: • The Power button turns the RACKMUX LCD and back light ON and OFF as desired.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 41 8.2.2 Brightness/Contrast Menu Selecting the Brightness/Contrast menu wi ll b ring up a screen in which the user c an a djust the brightness and contrast levels o f the LCD display.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 42 8.2.5 Setup Menu Selecting the Setup menu will brin g up a screen in which the user can adjus t OSD POSITION-the position of t he OSD menus on the L.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 43 9. KEYBOARD FUNCTIONS The keyboard on the RACKMUX has a stan dard co ndensed Windo ws format. To reduce the keyboard size, some ke ys have been assigned multiple functions, accessible via the "Fn" key.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 44 9.2 Number Pad The functionality of a Number Pad on a st andard Windo ws keyboard has been incorporat ed into this keyboard. To substitute the keys of the Number Pad To substitute the keys of the Number Pad: 1.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 45 9.3 Other Uses of the Function Key The Function (" Fn ") key (page 43) will enable other standard keyboar d feat ures in addition to the Number Pad keys (pa ge 44) .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 46 Figure 13- U.K. (Englis h) keyboard with numeric key pad Figure 14- German keyboard with numeric ke ypad 10. CPU-TO-RACKMUX ETHERNET CROSSOVER CABLE In order to make a direct connection between a CPU and th e ETHERNET conn ector of the RACKMUX, a crossover cable must be used.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 47 1 1. DC POWER OPTION If the RACKMUX has been ordered with the DC Power opti on (“48V” at th e end of the m odel number), a 3-terminal block has been provided for connection to a 36-72 VDC 2A power source.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 48 DIMENSIONAL DRA WINGS 1. 75 I N . 19 . 0 0 I N . Front View of RACK M U X-T15 Slott ed holes f or se curin g termi nal dr awer to r ack 15" L CD Display 2 1 .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 49 FREQUENTL Y ASKED QUESTIONS Questions and Answers Q. What servers can the monitor be used with? A. All Sun and headless servers to date i nclude at least one serial RS232 port that is used as a console port when no directly connected keyboard is prese nt.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 50 TECHNICAL SPECIFICA TIONS Physical Size (In.) WxDxH 19x21.9x1.725 Weight 23.3 lbs. Temperature 0°~40°C oper ating, -20°~60° C storage Humidity 20% t.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 51 TROUBLESHOOTING Each and every piece of every product prod uced by Network Tec hnologies Inc is 100% tested to exacting spec ifications. We make every effort to insure trouble-free installation a nd oper ation of our products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Network Technologies RACKMUX-T15 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Network Technologies RACKMUX-T15 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Network Technologies RACKMUX-T15 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Network Technologies RACKMUX-T15 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Network Technologies RACKMUX-T15, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Network Technologies RACKMUX-T15.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Network Technologies RACKMUX-T15. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Network Technologies RACKMUX-T15 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.