USER GUIDE AND SPECIFICA TIONS NI PMA-1115 Portable Monitor Accessor y This document includes an over vie w and specif ications for the NI PMA-1115 Portable Monitor Accessory . Over view The National Instruments PMA-1115 is a monitor and keyboard accessory for use with N I 8-slot PXI chassis.
NI PMA-1115 User Guide and Specifications 2 ni.com • V ideo cabling to connect PMA-1115 to PXI controller • Right-angle-to-v ertical USB cable •D r i v e r C D • Cable ties to organize po wer .
© National Instruments Corporation 3 NI PMA-1115 User Guide and Specifications Figure 2. Removing the Handle 3. Remov e the handle from the chassi s. Retain the handle. Discard the screws. 4. Attach the adapter plate to the chassis using the supplied M4 × 8 pan-head screws, as shown in Figure 3.
NI PMA-1115 User Guide and Specifications 4 ni.com 5. Reinstall the handle using the su pplied 4-40 × 5/16 pan-head screws, as sho wn in Figur e 4. Reinstall the handle covers b y snapping them ov er the handle mounti ng plates.
© National Instruments Corporation 5 NI PMA-1115 User Guide and Specifications 6. Orient the chassis and PMA-1115 as shown in Figure 5. Install the remaining M4 × 8 pan-head scre ws. Figure 5. Installing the PMA-1115 7. Open the keyboard and LCD, as shown in Figure 6.
NI PMA-1115 User Guide and Specifications 6 ni.com 8. If desired, use the provided in terlocking fastener to attach the A C adapter to the unit. One sugges ted location is shown in Figure 7. Cable ties are also provided to organize the po wer cabling.
© National Instruments Corporation 7 NI PMA-1115 User Guide and Specifications Ordering Information To order the NI PMA-1115 kit or power cords, refer to the following kit numbers. NI PMA-1115 Kit NI PMA-1115 Portable Monitor Accessory ............ .
NI PMA-1115 User Guide and Specifications 8 ni.com Display area ......... ....................... ............11.97 × 8.98 in. (30.41 × 22.81 cm) Contrast ratio ................... ................... .... 500:1 Brightness ....... ..................
© National Instruments Corporation 9 NI PMA-1115 User Guide and Specifications Operating Environment Ambient temperature range .................... 0 to 50 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature lim it.
NI PMA-1115 User Guide and Specifications 10 ni.com Figure 8. T emperature/Humidity Relationship Shock and Vibration Operational shock ............... ....................10 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27.) Random Vibration Operating .
© National Instruments Corporation 11 NI PMA-1115 User Guide and Specifications Safety and Compliance Safety This product is designed to meet the requirements of the follow ing standards of safety fo.
NI PMA-1115 User Guide and Specifications 12 ni.com Environmental Management National Instruments i s committed to designing and manu facturing products in an environmental ly responsible mann er. NI recognizes that eliminating certa in hazardous substances from our products is beneficial not only to t he environment but also to NI customers.
© National Instruments Corporation 13 NI PMA-1115 User Guide and Specifications Where to Go for Support The National Instruments Web site is your complete resource for technical support.
NI PMA-1115 User Guide and Specifications 14 ni.com Important Information Warranty The PMA-1115 is warranted agains t defects in materials and workman ship for a period of one year from the date of shipment, as e videnced by receipts or other documentation.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more infor mation about Na tional Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il National Instruments Portable Monitor Accessory NI PMA-1115 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del National Instruments Portable Monitor Accessory NI PMA-1115 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso National Instruments Portable Monitor Accessory NI PMA-1115 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul National Instruments Portable Monitor Accessory NI PMA-1115 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il National Instruments Portable Monitor Accessory NI PMA-1115, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del National Instruments Portable Monitor Accessory NI PMA-1115.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il National Instruments Portable Monitor Accessory NI PMA-1115. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo National Instruments Portable Monitor Accessory NI PMA-1115 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.