WS-415-71 / 09.07.00 1 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. THIS FIREPLACE HAS BEEN TESTED AND LISTED BY WARNOCK HERSEY L TD.
WS-415-71 / 09.07.00 2 PLEASE RET AIN THIS MANU AL FOR FUTURE REFERENCE Congratulations on the purchase of your Napoleon hi-tech, high efficient solid fuel burning fireplace! It has been extensively tested in Canadian and American laboratories .
WS-415-71 / 09.07.00 3 NAPOLEON wood fireplaces are manufactured under the strict Standard of the World Recognized ISO9002 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
WS-415-71 / 09.07.00 4 INTRODUCTION GENERAL INFORMA TION This is the most efficient, sim- ple and trouble free woodburning system we know of and works as follows: Primary combustion air enters through.
WS-415-71 / 09.07.00 5 CARE OF GLASS AND PLA TED PA R T S If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fire will clean the glass.
WS-415-71 / 09.07.00 6 These options may be incorporated with one another . If the optional blowers are to be installed, make provision dur- ing framing to route a 1 10 volt power line to the fireplace. Detailed installation instructions are included with each venting kit.
WS-415-71 / 09.07.00 7 HEARTH EXTENSION An acceptable 16" x 50" non-combustible (ie: brick, stone or ceramic tile) hearth extension must be installed.
WS-415-71 / 09.07.00 8 FIGURE 10 - 4 ELBOWS FIGURE 9 - 2 ELBOWS FIGURE 8 - STRAIGHT UP No Off-Set. Minimum overall chim- ney height is 15 feet. Single off-set with two 15°, 30° or 45° elbows. Minimum overall chimney height is 15 feet. Double off-set with four 15°, 30° or 45° elbows.
WS-415-71 / 09.07.00 9 1. Move the fireplace into position. Try to center the ex- haust flue of the fireplace, midpoint between two joists to prevent having to cut them.
WS-415-71 / 09.07.00 10 FINISHING FIREBRICK REMO V AL: The fireplace is shipped with the firebricks in place, how- ever if you need to remove them (ease of installation, re- placement, etc), follow this sequence: Remove the ashwell grate.
WS-415-71 / 09.07.00 11 OPTIONAL BLOWER INST ALL A TION NST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in ac- cordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE.
WS-415-71 / 09.07.00 12 NZ25 FEA TURES CONTROLLING COMBUSTION AIR: If the outside combustion air kit is not used, air may still be drawn directly into the fireplace through the lower louvres. Outside and inside air may be combined by pulling the outside air lever out as far as possible, and turning the lever 90° to its locking position.
WS-415-71 / 09.07.00 13 ASH REMO V AL PROCEDURES A bed of ashes approximately 1 inch deep should be left on the firebox bottom to help maintain a hot charcoal bed. When the fire has burned down and cooled, remove any excess ashes. T o use your ash pan, pull the ash dump handle forward to an open position.
WS-415-71 / 09.07.00 14 FIRE EXTINGUISHERS AND SMOKE DETECT ORS All homes with a solid fuel burning fireplace should have at least one fire extinguisher in a central location, known to all, and at least one smoke detector in the room containing the fireplace.
WS-415-71 / 09.07.00 15 REPLACEMENT P ARTS P ART N O. DESCRIPTION NZ-H333 BLACK DOOR C / W HANDLE & GASKET NZ-H333G GOLD PLA TED DOOR C / W HANDLE & GASKET WS-300-04 DOOR GLASS ONL Y EP-562.010 DOOR GASKET EP-562.016 GLASS GASKET WS-325-07 LARGE SPRING HANDLE WS-325-02 SMALL SPRING HANDLE GA GD-715.
WS-415-71 / 09.07.00 16 TROUBLE SHOOTING Build your fire on the floor of the firebox and be- hind the log retainer only . Do not block or restrict the hot air outlets or air inlets . This will cause the fir eplace to ov erheat. Keep fires away from the door .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces NZ25 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces NZ25 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces NZ25 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces NZ25 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces NZ25, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces NZ25.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces NZ25. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces NZ25 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.