1 W415-0559 / 02.15.06 W415-0559 / 02.07.06.
2 W415-0559 / 02.15.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0559 / 02.15.06 W ARNING • Under no cir cumstances should this heater be modified. • Pr ovide adequate v entila tion and combustion air . Pr ovide adequa te accessibility c learance f or servicing and oper ating the hea ter . Ne ver obstr uct the front opening of the heater .
4 W415-0559 / 02.15.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0559 / 02.15.06 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane.
6 W415-0559 / 02.15.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" Pr ovide adequate v entilation and combustion air . Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stov e.
7 W415-0559 / 02.15.06 BL O WER INST ALLA TION GAS INST ALLA TION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector . DO NOT KINK FLEXIBLE CONNECTOR.
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners.
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw , on the right side of the burner . The bottom branch of log #3 sits infront of, and against, the right end of log #2.
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour ’s phone. Follow the gas supplier ’s instructions. • If you cannot reach your gas supplier , call the fi re de- partment.
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly , remove the logs exposing both assemblies.
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
13 W415-0559 / 02.15.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
15 W415-0559 / 02.15.06 Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces GVFS20P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces GVFS20P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces GVFS20P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces GVFS20P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces GVFS20P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces GVFS20P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces GVFS20P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces GVFS20P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.