Manuale d’uso / di manutenzione del prodotto GDS20P del fabbricante Napoleon Fireplaces
Vai alla pagina of 28
1 W415-0496 / B / 08.10.05 W415-0496 / B / 08.10.05.
2 W415-0496 / B / 08.10.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
3 W415-0496 / B / 08.10.05 WARNING • The sto ve is a vented g as-fi r ed hea ter . Do not b urn wood or other materials in this sto ve . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
4 W415-0496 / B / 08.10.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0496 / B / 08.10.05 Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. This appliance is only for use with the type of gas indicated on the rating plate . This appliance is not convertible for use with other gases, unless a certified kit is used.
6 W415-0496 / B / 08.10.05 MAINT AIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP ............
7 W415-0496 / B / 08.10.05 BLO WER INST ALLA TION Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower .
8 W415-0496 / B / 08.10.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended t o use a heat shield and to maximize the distance to vinyl c lad sof fits .
9 W415-0496 / B / 08.10.05 Use only Wolf S teel, Simpson Dura-V ent, Selkirk Direct T emp or American Met al Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components.
10 W415-0496 / B / 08.10.05 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
11 W415-0496 / B / 08.10.05 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE .
12 W415-0496 / B / 08.10.05 V 1 HORIZONT AL TERMINA TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
13 W415-0496 / B / 08.10.05 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.
14 W415-0496 / B / 08.10.05 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H.
15 W415-0496 / B / 08.10.05 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN.
16 W415-0496 / B / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24 . Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run.
17 W415-0496 / B / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flex- ible liner to the stove. Secure with 3 screws and flat wash- ers. Seal the joint and screw holes using high tempera- ture sealant.
18 W415-0496 / B / 08.10.05 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corners.
19 W415-0496 / B / 08.10.05 LOG PLACEMENT LOGO PLACEMENT Remove the backing from the the logo and position onto the control door as shown. It is not necessary to rem ove the cast fr ont, however , this will make for a more simple log installation.
20 W415-0496 / B / 08.10.05 Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door . The on-off switch is located on the back of the unit at the top right corner on model GDS20. When lit for the first time, the fireplace will emit a slight odour for a few hour s .
21 W415-0496 / B / 08.10.05 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . FIGURE 34 FIGURE 35 Air shutter adjustment must only be done .
22 W415-0496 / B / 08.10.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor . When ordering replacement parts always give the fol- lowing information: 1.
23 W415-0496 / B / 08.10.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
24 W415-0496 / B / 08.10.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
25 W415-0496 / B / 08.10.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection.
26 W415-0496 / B / 08.10.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
27 W415-0496 / B / 08.10.05 NO TES.
28 W415-0496 / B / 08.10.05 NO TES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces GDS20P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces GDS20P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces GDS20P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces GDS20P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces GDS20P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces GDS20P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces GDS20P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces GDS20P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.