Manuale d’uso / di manutenzione del prodotto GDI-30N del fabbricante Napoleon Fireplaces
Vai alla pagina of 16
1 W415-0384 / D / 09.13.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0384 / D / 09.13.05 WARNING • The fireplace insert is a vented gas-fired heater . Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0384 / D / 09.13.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0384 / D / 09.13.05 cle. The grounding prong must not be removed from the cord plug. FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane.
5 W415-0384 / D / 09.13.05 WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result. Pro vide adequate v entilation air . Provide adequate accessibility clearance for ser vicing and operating the fireplace inser t.
6 W415-0384 / D / 09.13.05 FIGURE 2 Move the insert close to its final position inside the wood- burning fireplace. This unit is equipped with 4 levelling screws located in the four inside corners beneath the log support. Level using the levelling screws to eliminate rock- ing or excessive noise when the fan is in operation.
7 W415-0384 / D / 09.13.05 T ABS FINISHING Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner .
8 W415-0384 / D / 09.13.05 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow sev eral minutes (5-15) f or the flame to stabilize after ignition. Do not operate the main burner of the in- sert with the door opened.
9 W415-0384 / D / 09.13.05 7. Depress slightly and hold gas knob while lighting the pilot with the push button ignitor . Keep knob depressed for one minute, then release. If pilot does not continue to burn, re- peat steps 3 through 7. 8. With pilot lit, depress and turn gas knob counter-clock- wise to on.
10 W415-0384 / D / 09.13.05 FIGURE 9 BLOWER ACCESS COVER 1. Turn off the electri- cal power and the gas supply to the fireplace insert. 2. Open the glass door and remove the logs and fibre bricks, if in- stalled. 3. Remove the blower access cover held on with 4 screws.
11 W415-0384 / D / 09.13.05 # P ART # DESCRIPTION 1 GZ552 REPLACEMENT BLOWER 2 W725-0035 NA TURAL GAS V AL VE 2 W725-0026 PROP ANE GAS V AL VE 3 W455-0019 #43 NA TURAL GAS BURNER ORIFICE 3 W455-0003 #.
12 W415-0384 / D / 09.13.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
13 W415-0384 / D / 09.13.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
14 W415-0384 / D / 09.13.05 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
15 W415-0384 / D / 09.13.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
16 W415-0384 / D / 09.13.05 NO TES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces GDI-30N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces GDI-30N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces GDI-30N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces GDI-30N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces GDI-30N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces GDI-30N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces GDI-30N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces GDI-30N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.