1 W415-0275 / C / 09.23.05 R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, C SA 2.22, AND ANSI Z21.50 RESPECTIVEL Y FOR VENTED GAS FIREPLACES.
2 W415-0275 / C / 09.23.05 WARNING • The product is a vented gas fireplace. Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0275 / C / 09.23.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0275 / C / 09.23.05 Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
5 W415-0275 / C / 09.23.05 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0275 / C / 09.23.05 P I P I L O T 3 1 2 N O L O T H I L O F F O It is best to frame your fireplace after it is positioned and the vent system is installed.
7 W415-0275 / C / 09.23.05 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. FIGURE 13 a FIGURE 13 b NAILING T AB FIGURE 1 1 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup- plied.
8 W415-0275 / C / 09.23.05 The upper louvres must be removed to allow the door to be opened or closed. To access the lower door latch, open the valve con- trol door. Release the top and bottom door latches, lo- cated at the right side of the door. UPPER L OUVRE S : Insert the upper louvres into the slots on both brackets.
9 W415-0275 / C / 09.23.05 4. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log. 5. Place the bottom of the right crossover log (#6) against the right firebox side and pulled forward to the grate.
10 W415-0275 / C / 09.23.05 Attach the connectors from the black and white wires to the thermodisc and se- cure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
11 W415-0275 / C / 09.23.05 RECEPTACLE / JUNCTION BOX OPTIONAL THERMOSTATIC SENSOR SLOTS OPEN ENDED BRACKET VARIABLE SPEED/ PIEZO IGNITOR JUNCTION BOX THERMODISC SENSOR ASSEMBLY BRACKET RECEPTACLE / A.
12 W415-0275 / C / 09.23.05 FLAME ADJUSTMENT KNOB O T P I L L O I H T P I L O N O F F O PILOT ON/OFF KNOB • T urn off all gas to the fireplace. • O pen windows. • D o not try to light any appliance. • D o not touch any electric switch; do not use any phone in your building.
13 W415-0275 / C / 09.23.05 AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED GAS INSTALLER! Air shutter is accessed beside gas valve. P I P I PILOT SCREW L O T N O L O T H I L O F F O Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.
14 W415-0275 / C / 09.23.05 # P AR T NO . DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0764 BURNER 5 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 5 W010-0801 .
15 W415-0275 / C / 09.23.05.
16 W415-0275 / C / 09.23.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
17 W415-0275 / C / 09.23.05 P I A B P I L O T N O L O T H I L O F F O White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HO T.
18 W415-0275 / C / 09.23.05 Wol f Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer N.
19 W415-0275 / C / 09.23.05 NO TES.
20 W415-0275 / C / 09.23.05 NO TES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces BGNV36N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces BGNV36N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces BGNV36N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces BGNV36N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces BGNV36N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces BGNV36N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces BGNV36N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces BGNV36N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.