THIS MANU AL MUST A CCOMP ANY THE EQ UIPMENT A T ALL TIMES. To fi nd the latest revision of this publication, visit our website at: www .mqpo wer .com WHISPER W A TT™ SERIES MODEL DCA125SSIU 60HZ GENERA TOR (ISUZU 4HK1X DIESEL ENGINE) P AR TS LIST NO.
P A GE 2 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) PROPOSITION 65 W ARNING Diesel engine exhaust and some of.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 3 If you belie ve that your v ehicle has a defect that could cause a crash or could cause injur y or d.
P A GE 4 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) T ABLE OF CONTENTS DCA125SSIU Generator Proposition 65 Warning ........................................... 2 Repor ting Safety Def ects ...............
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 5 P AR TS ORDERING PROCEDURES www .mqpo w er .com Or dering par ts has never been easier! Choose fr om.
P A GE 6 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) SAFETY INFORMA TION Do not operate or service the equipment before reading the entire manual. Safety precautions should be f ollow ed at all times when operating this equipment.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 7 SAFETY INFORMA TION GENERAL SAFETY CA UTION NEVER operate this equipment without proper protecti.
P A GE 8 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) SAFETY INFORMA TION ENGINE SAFETY D ANGER The engine fuel e xhaust gases contain poisonous carbon mono xide. This gas is colorless and odorless, and can cause death if inhaled.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 9 SAFETY INFORMA TION FUEL SAFETY D ANGER DO NO T star t the engine near spilled fuel or comb ustible fl uids. Diesel fuel is e xtremely fl ammable and its v apors can cause an e xplosion if ignited.
P A GE 10 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) SAFETY INFORMA TION ELECTRICAL SAFETY D ANGER DO NO T touch output terminals dur ing operation. Contact with output ter minals during operation can cause electrocution, electrical shock or b urn.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 11 SAFETY INFORMA TION B A TTER Y SAFETY D ANGER DO NO T drop the batter y . There is a possibility that the batter y will e xplode. DO NO T expose the battery to open fl ames, sparks, cigarettes, etc.
P A GE 12 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) T able 1. Generator Specifi cations Model DCA-125SSIU T ype Rev olving fi eld, self v entilated, open protected type synchronous generator Armature Connection Star with Neutral Zigzag Phase 3 Single Standby Output 110 KW (137.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 13 DIMENSIONS Figure 1. Dimensions T able 3. Dimensions Reference Letter Dimension in. (mm) Reference Letter Dimension in. (mm) A 34.76 in. (883 mm.) F 120 in.
P A GE 14 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) INST ALLA TION Figure 2. T ypical Generator Grounding Application.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 15 INST ALLA TION OUTDOOR INST ALLA TION Install the generator in a area that is free of debris, bystanders , and ov erhead obstr uctions. Make sure the generator is on secure le v el ground so that it cannot slide or shift around.
P A GE 16 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR The MQ P ower Model DCA125SSIU generator (Figure 3) is a high quality por table (require.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 17 MAJOR COMPONENTS T able 4. Generator Major Components ITEM NO .
P A GE 18 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR CONTROL P ANEL Figure 4. Generator Control P anel A V HZ OFF W U V OFF W-U V-W U-V DECRE.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 19 NOTES.
P A GE 20 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENGINE OPERA TING P ANEL Figure 5. Engine Operating Panel A V HZ OFF W U V OFF W-U V- W U-V DECREAS.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 21 ENGINE OPERA TING P ANEL The defi nitions belo w describe the controls and functions of the DCA-125SSIU Engine Operating P anel (Figure 5). 1. Oil Pressure Gauge — During nor mal operation this gauge should read between 42 ~71 psi.
P A GE 22 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) OUTPUT TERMINAL P ANEL F AMILIARIZA TION OUTPUT TERMINAL P ANEL The Output T er minal Panel (Figure 6) sho wn below is located on the right-hand side (left from control panel) of the generator .
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 23 OUTPUT TERMINAL P ANEL F AMILIARIZA TION 120 V A C GFCI Receptacles There are two 120 V AC , 20 amp GFCI (Duple x Nema 5-20R) receptacles provided on the output terminal panel.
P A GE 24 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) OUTPUT TERMINAL P ANEL F AMILIARIZA TION Connecting Loads Loads can be connected to the generator b y the Output T erminal Lugs or the conv enience receptacles (Figure 10).
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 25 LOAD APPLICA TION SINGLE PHASE LO AD Alwa ys be sure to check the nameplate on the generator and eq.
P A GE 26 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR OUTPUTS GENERA TOR OUTPUT V OL T A GES A wide range of v oltages are av ailable to supply v oltage f or many diff erent applications. V oltages are selected by using the volta ge selector s witch (Figure 12).
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 27 GENERA TOR OUTPUTS/GAUGE READING HO W T O READ THE OUTPUT TERMINAL GA UGE The A C ammeter and A C v oltmeter change-ov er switches on the control panel DO NO T eff ect the generator output.
P A GE 28 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) OUTPUT TERMINAL P ANEL CONNECTIONS UVWO TERMINAL OUTPUT V OL T A GES V ar ious output voltages can be obtained using the UVW O output ter minal lugs.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 29 OUTPUT TERMINAL P ANEL CONNECTIONS 3Ø-480/277V UVWO T erminal Output V oltages 1. Place the voltage selector s witch in the 3Ø 480/277 position as shown in Figure 23.
P A GE 30 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) INSPECTION/SETUP CIRCUIT BREAKERS T o protect the generator from an ov er load, a 3-pole, 300 amp , main circuit break er is provided to protect the U,V , and W Output T erminals from overload.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 31 INSPECTION/SETUP Refueling Procedure: 1. Level T anks — Make sure fuel cells are le vel with the ground. Failure to do so will cause fuel to spill from the tank bef ore reaching full capacity (Figure 29).
P A GE 32 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) COOLANT (ANTIFREEZE/SUMMER COOLANT/ W A TER) ISUZU recommends ISUZU antifreeze/summer coolant f or use in their engines, which can be purchased in concentrate (and mix ed with 50% demineralized w ater) or pre-diluted.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 33 B A TTER Y This unit is of negative g round DO NO T connect in rev erse. Alwa ys maintain batter y fl uid lev el between the specifi ed marks. Batter y life will be shortened, if the fl uid le v el are not properly maintained.
P A GE 34 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR ST AR T -UP PROCEDURE (MANUAL) BEFORE ST ARTING 1. Place the main, G.F .C.I., and aux. circuit break ers ( Figure 35 ) in the OFF position prior to star ting the engine.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 35 GENERA TOR ST AR T -UP PROCEDURE (MANUAL) 6. The generator’ s frequency meter (Figure 42) should be displa ying the 60 cycle output frequency in HERTZ.
P A GE 36 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR ST AR T -UP PROCEDURE (AUTO MODE) ST ARTING (A UT O MODE) When star ting generator in AU T O mode use the “Manual Star t-up” procedure e xcept where noted (see below).
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 37 GENERA TOR SHUT -DOWN PROCEDURES NORMAL SHUTDO WN PROCEDURE T o shutdown the generator , use the following procedure: 1. Place both the MAIN, GFCI and LO AD circuit breakers as shown in Figure 35 to the OFF position.
P A GE 38 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) * 1 Replace engine oil and fi lter at 100 hours, fi rst time only . * 2 Add “Supplemental Coolant Additiv es (SCA’S)” to recharge the engine coolant.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 39 MAINTENANCE If the engine is operating in v ery dusty or dr y grass conditions, a clogged air cleaner will result. This can lead to a loss of power , excessiv e carbon buildup in the comb ustion chamber and high fuel consumption.
P A GE 40 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) CHECK OIL LEVEL Check the cr ankcase oil le v el prior to each use, or when the fuel tank is fi lled. Insuffi cient oil may cause se vere damage to the engine.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 41 MAINTENANCE JA CKET W A TER HEA TER AND INTERNAL B A TTER Y CHARGER 120 V A C INPUT RECEPT ACLES (OPTIONAL) This generator can be optionally equipped with two 120 V AC , 20 amp input receptacles located on the output ter minal panel.
P A GE 42 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TRAILER MAINTENANCE TRAILER MAINTENANCE This section is intended to provide the user with generic trailer service and maintenance information. The ser vice and maintenance guidelines ref erenced in this section ref er to a wide range of trailers .
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 43 TRAILER MAINTENANCE BRAKES T railer brak es should be inspected the fi rst 200 miles of operation. This will allo w the brak e shoes and drums to seat properly .
P A GE 44 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TRAILER MAINTENANCE TIRES/WHEELS/LUG NUTS Tires and wheels are a very impor tant and cr itical components of the trailer . When specifying or replacing the trailer wheels it is impor tant the wheels, tires, and axle are properly matched.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 45 TRAILER MAINTENANCE Lug Nut T orque Requirements It is e xtremely impor tant to apply and maintain proper wheel mounting torque on the trailer . Be sure to use only the f asteners matched to the cone angle of the wheel.
P A GE 46 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TRAILER WIRING DIAGRAM Figure 62. T railer/T owing V ehicle Wiring Diagram.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 47 GENERA TOR WIRING DIAGRAM Figure 63. Generator Wiring Diagram.
P A GE 48 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENGINE WIRING DIAGRAM Figure 64. Engine Wiring Diagram.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 49 CONTROLLER WIRING DIAGRAM Figure 65. Controller Wiring Diagram.
P A GE 50 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TROUBLESHOOTING (GENERA TOR) Practically all breakdowns can be pre vented b y proper handling and maintenance inspections, b ut in the e v ent of a breakdown, use T able 19 sho wn below f or diagnosis of the Generator .
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 51 TROUBLESHOOTING (ENGINE CONTROLLER) Practically all breakdowns can be pre vented b y proper handlin.
P A GE 52 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TROUBLESHOOTING (DIAGNOSTIC LAMP) The engine controller of this generator diagnoses prob lems that arise from the engine control system and the engine itself .
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 53 NOTES.
P A GE 54 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) EXPLANA TION OF CODE IN REMARKS COLUMN The f ollo wing section e xplains the diff erent symbols and remarks used in the P ar ts section of this manual.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 55 SUGGESTED SP ARE P AR TS DCA125SSIU WHISPER W A TT GENERA T OR WITH ISUZU 4HK1X DIESEL ENGINE 1 to 3 units QTY . P/N DESCRIPTION 1............M3310502203 .
P A GE 56 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) GENERA TOR ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 57 GENERA TOR ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 1 C0110001002 RO T OR ASSY 1 *1-1 FIELD ASSY 1 1-2 8131070013 F AN 1 1-3 8131611014 COUPLING DISK 8 1-4 8131015003 BALANCING PLA TE .
P A GE 58 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) CONTROL BOX ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 59 NO . P ART NO . P ART NAME QTY . REMARKS 1 M3213001702 CONTROL BO X 1 1-1 0330000210 EDGING 2 1-2 0.
P A GE 60 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) CONTROL BOX ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 61 CONTROL BOX ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 33 0027106016 MA CHINE SCREW 2 34 5825500290 RELA Y ......................................
P A GE 62 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) CONTROL BOX ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 63 CONTROL BOX ASSY . NO . P ART NO . P ART NAME QTY .
P A GE 64 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENGINE AND RADIA TOR ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 65 ENGINE AND RADIA TOR ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 1 M3923200134 ENGINE, ISUZU 4HK1X 1 1A 8980527130 F AN BEL T ....................
P A GE 66 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENGINE AND RADIA TOR ASSY . (CONTINUED).
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 67 ENGINE AND RADIA TOR ASSY . (CONTINUED) NO . P ART NO . P ART NAME QTY . REMARKS 41 0602021070 CAP 1 42 0269200600 DRAIN HOSE 1 43 M3323500004 OIL FIL TER BRACKET 1 44 0016910025 HEX HEAD BOL T 2 45 8973243861 OIL FIL TER .
P A GE 68 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) OUTPUT TERMINAL ASSY . ADD THE FOLLOWING DIGITS AFTER THE P ART NUMBER WHEN ORDERING ANY P AINTED P.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 69 OUTPUT TERMINAL ASSY . NO . P ART NO . P ART NAME QTY .
P A GE 70 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) BA TTER Y ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 71 BA TTER Y ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 1 0602220198 BA TTER Y 1 2 M9310500404 BA.
P A GE 72 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) MUFFLER ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 73 MUFFLER ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 1 M3330100902 MUFFLER 1 2 0016910025 HEX HEAD BOL T 4 3 M3333001403 EXHA UST PIPE 1 4 1141451840 GASKET .
P A GE 74 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) FUEL T ANK ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 75 FUEL T ANK ASSY . NO . P ART NO . P ART NAME QTY .
P A GE 76 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENCLOSURE ASSY . ADD THE FOLLOWING DIGITS AFTER THE P ART NUMBER WHEN ORDERING ANY P AINTED P ANEL .
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 77 ENCLOSURE ASSY . NO . P ART NO . P ART NAME QTY . REMARKS 1 M3413002402 BASE 1 2 M1413400004 CO VER.
P A GE 78 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENCLOSURE ASSY . (CONTINUED) ADD THE FOLLOWING DIGITS AFTER THE P ART NUMBER WHEN ORDERING ANY P AI.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 79 ENCLOSURE ASSY . (CONTINUED) NO . P ART NO . P ART NAME QTY .
P A GE 80 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) ENCLOSURE ASSY . (CONTINUED) ADD THE FOLLOWING DIGITS AFTER THE P ART NUMBER WHEN ORDERING ANY P AI.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 81 NO . P ART NO . P ART NAME QTY . REMARKS 62 0600800320 MANU AL P AK 1 63 0021806016 MA CHINE SCREW .
P A GE 82 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) RUBBER SEALS ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 83 RUBBER SEALS ASSY . NO . P ART NO . P ART NAME QTY .
P A GE 84 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) NAMEPLA TE AND DECALS ASSY ..
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 85 NAMEPLA TE AND DECALS ASSY . NO . P ART NO . P ART NAME QTY .
P A GE 86 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) NAMEPLA TE AND DECALS ASSY . (CONTINUED).
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 87 NAMEPLA TE AND DECALS ASSY . (CONTINUED) NO . P ART NO . P ART NAME QTY . REMARKS FUEL T ANK GROUP 7-1 M9500500004 DECAL : DIESEL FUEL ...............
P A GE 88 — DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) TERMS AND CONDITIONS OF SALE — P AR TS P A YMENT TERM S T er ms of payment for parts are net 3 0 days. FREIGHT POLI CY All par ts order s will be ship ped co llect or prepaid with th e charg es adde d to the invoice.
DCA125SSIU 60 HZ GENERA T OR • OPERA TION AND P ARTS MANU AL — REV . #3 (01/13/11) — P A GE 89 NOTES.
OPERA TION AND P AR TS MANUAL Y our Local Dealer is: HERE’S HOW TO GET HELP PLEASE HA VE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED ST A TES Multiquip Corporate Office MQ P arts Depar tment 18910 Wilmington A v e. Carson, CA 90746 Contact: mq@multiquip .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Multiquip DCA125SSIU è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Multiquip DCA125SSIU - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Multiquip DCA125SSIU imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Multiquip DCA125SSIU ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Multiquip DCA125SSIU, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Multiquip DCA125SSIU.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Multiquip DCA125SSIU. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Multiquip DCA125SSIU insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.