Manuale d’uso / di manutenzione del prodotto AWK-3131-M12-EU del fabbricante Moxa
Vai alla pagina of 16
20 11 Moxa Inc . A ll rights re served. P/N: 1802031310010 AWK- 3131 Hardware Installation Guide Moxa AirWorks First Edition, February 2011.
- 2 - Overview Moxa's new AWK - 3131 3 - in - 1 industri al wi reless AP /bridg e/clie nt meets the growing need for faster data transmission speeds and w ider coverage by supporting IEEE 80 2.11n technology with a net data rat e of up t o 300 Mbps.
- 3 - • SFP - 1GLHXLC: Small form factor pluggable transceiver w ith 1000BaseLHX , LC, 40 km, 0 to 60°C • SFP - 1GLHXLC - T: Small form factor pluggabl e trans ceiver with 1000BaseLHX , LC, 40 km.
- 4 - ATTENTION For security reasons, we strongly recommend ch anging the password. To do so, select Maintenance Password , and then follow the on - screen instructions. Step 5: Se lect the operation m ode for th e AWK - 31 31 By default, the AWK - 31 3 1’s operation mode is set to AP.
- 5 - Panel Layout of the AWK - 3131 1. Grounding screw 2. Terminal block for PWR1,PWR2, relay, DI1, and DI2 3. Reset button 4. System LEDs: PWR1, PWR2, PoE, FAULT, and STATE LED s 5. LEDs for signal strength 6. WLAN LED 7. Ethernet or Fiber LED 8. RS - 232 console port 9.
- 6 - Mounting Dimensions (unit = mm) DIN - Rail Mounting The aluminum DIN - Rail attachmen t plate should be fixed to the back panel of the AWK - 3131 when you take it out of the box.
- 7 - Wall Mounting (optional) For transportation app lications that require a n EN 50155 certification report, we strongly r ecommend the purchase of the optional AWK- 3131 wallmount kit, whic h has passed E N 50155 testing. Th is wallmount kit is also convenient for other a pplications that requ ire mounting the AWK- 3131 to a wall.
- 8 - WARNING • This equipment is intended to be used in a Restrict ed Access Location, such as a ded icated computer room . A ccess can only be gained by SERVICE PERSONS or by USERS who ha ve been instructed about the fact tha t the metal chassis of the equi pment i s extremely hot and m a y cause burns.
- 9 - ATTENTION This product is inte nded to be supplied by a Listed Power Unit marked “ Class 2 ” or “ LPS ” and rated O/P: 12 to 48 V DC , minim um 6 W (12 V to 48V), 25°C .
- 10 - ATTENTION Before connecting the AWK - 3131 to the DC power inputs, mak e sure the DC power source vo ltage is stable. Wiring the Relay Contact The AWK - 3131 has one relay output, wh ich consists of the t wo contacts of the terminal block on the AWK - 3131 ’s top pane l.
- 11 - Communication Con nections 10/100BaseT(X) Ethern et Port Connection The 10/100BaseT(X) ports located on the AWK- 31 31 ’s front panel are used to connect to Ethernet- enabled devices. Below we show pinouts for both MDI (NIC - type) po rts and MDI -X (HUB/Switch - type) ports.
- 12 - NOTE 1. The pin numbers for ma le DB9 and DB25 conne ctors, and hole numbers for fema le DB9 and DB25 con nectors are labeled on the connecto r. However, the number s are typically quite small, so y ou may need to us e a magnifying glass to see the numbers clearl y.
- 13 - LAN Green/ Amber Amber LAN port’s 10/ 100 Mbps link is active. Amber Blink ing Data is being transmitted at 10/100 Mbps Amber Off LAN port’s 10/ 100 Mbps link is inactive Green LAN port’s 1000 Mbps link is active.
- 14 - TX Transmit Power: 802.11b: 1 to 11 Mbps: Typ. 18 dBm (± 1.5 dBm) 802.11g: 6 to 24 Mbps: Typ. 18 dBm (± 1.5 dBm) 36 to 48 Mbps: Typ. 17 dBm (± 1.5 dBm) 54 Mbps: Typ. 1 5 dBm (± 1.5 dB m) 802.11a: 6 to 24 Mbps: Typ. 17 dBm (± 1.5 dBm) 36 to 48 Mbps: Typ.
- 15 - Alarm Contact: 1 relay output w ith current carry ing capacity of 1 A @ 24 VDC Digital Inputs: 2 electrically isolated inputs • +13 to +30 V for state “1” • +3 to - 30 V for state “0” • Max. input current: 8 mA Physical Characteristics Housing: Metal, IP30 protection Weight: 970 g Dimensions: 53.
- 1 6 - ATTENTION Use the antennas corr ectly: The 2.4 GHz ante nnas are needed when the AWK - 3131 operates in IEEE 802.11b/ g/ n . The 5 GHz antennas are needed fo r IEEE802.11a /n . Make sure your ante nna installation is within a safety area, which is covered by a lightning protection or surge arr est system.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Moxa AWK-3131-M12-EU è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Moxa AWK-3131-M12-EU - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Moxa AWK-3131-M12-EU imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Moxa AWK-3131-M12-EU ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Moxa AWK-3131-M12-EU, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Moxa AWK-3131-M12-EU.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Moxa AWK-3131-M12-EU. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Moxa AWK-3131-M12-EU insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.