Manuale d’uso / di manutenzione del prodotto 242 del fabbricante Armstrong World Industries
Vai alla pagina of 196
Ser vice Refer ence Manual HWC Thru-the-Wall Units Models: HWC Premier 122, 182, 242, 302 123, 183, 243, 303.
SRM-HW/HWC 8/99 Cop yr ight © 1998 Ar mstrong Air Conditioning Inc. All rights reser v ed. Disclaimer This manual presents inf ormation and guidelines for proper installation, adjustment, operation and maintenance of Armstrong Magic-Pak HW/HWC Thru-the-Wall units .
Service Refer ence Manual T ABLE OF CONTENTS SRM-HW/HWC 8/99 T ABLE OF CONTENTS 1 - Specifications 2 - Sequence of Operations 3 - Unit T ear Down 4 - Component Location Illustrations 5 - Unit Componen.
1-1 SRM-HW/HWC 8/99 Service Refer ence Manual SPECIFICA TIONS Section 1 - Specifications Models Cover ed By This Manual ............ 1-2 Model Number Guide ............................ 1-2 Pr oduct Serial Numbers (Beginning 1993) .....................
1-2 SPECIFICA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Models Cover ed By This Manual HWC Gas Heating/Electric Cooling Units HW122, 123 HW182,183 HW242, 243 HW302, 303 HW Gas Heating Only Units 26HW 38.
1-3 SRM-HW/HWC 8/99 Service Refer ence Manual SPECIFICA TIONS Summar y of Model Revisions/V ariations * For more inf or mation on the compressors used in HWC units, see the Unit Components section, beginning on page 5-28.
1-4 SPECIFICA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Physical and Electrical HW/HWC Per formance Ratings T able 1-3 Physical and Electrical Specifications - HWC Units l e d o M / e g a t l o V e s a h P / z H l a m r o N e g a t l o V e g n a R . n i M t i u c r i C y t i c a p m A .
1-5 SRM-HW/HWC 8/99 Service Refer ence Manual SPECIFICA TIONS Per formance Ratings (continued) T able 1-5 P erformance Ratings - HWC182/183 T able 1-6 P erformance Ratings - HWC242/243 T able 1-7 P erformance Ratings - HWC302/303 Note: All values are gross capacities and do not include b lower motor heat deduction.
1-6 SPECIFICA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Dimensions (all measur ements in inches) Blower Per for mance Model Blower Speed CFM @ ext. static pressure - in.
1-7 SRM-HW/HWC 8/99 Service Refer ence Manual SPECIFICA TIONS W all Sleeve (all measurements in inches) 22 16 8 6 Return Supply 1 1 1 Supply Low Vo l t a g e Line V oltage Box ½ Gas Inl et 3 8 4 1 3 / 4 2 7 / 8 13 3 / 8 43 1 / 8 27 7 / 8 29 7 / 16 2 7 / 8 Dimensions (cont.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-1 SRM-HW/HWC 2/99 Section 2 - Sequence of Operation HWC123,183,243,303 ........................ 2-4 Simplified Sequence ........................................ 2-5 Detailed Sequence ................
SPECIFICA TIONS Magic-Pak: HW/HWC 2-2 SRM-HW/HWC 2/99 HWC122,182,242,302 (w/Fenwal 05-29 Ignition Contr ol) ....... 2-26 Simplified Sequence ...................................... 2-27 Detailed Sequence ........................................ 2-28 PO WER .
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-3 SRM-HW/HWC 2/99 BLANK P A GE.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-4 SRM-HW/HWC 2/99 FIGURE 2-1 Connection Diagram GREEN BLACK BLK M ORN ORN VIOLET RED BLUE WHT RED BLACK BLUE YELLOW WHITE GREEN RED FLAME ROD ELECTRODE 4 6 2 R G W .
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-5 SRM-HW/HWC 2/99 Simplified Sequence - HWC123,183, 243, 303 Refer to Figur e 2-1 • 208/230V pow er is supplied to the junction box on top of the unit • 24V power is supplied from the unit tr ansf ormer to the thermostat CALL FOR HEAT 1.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-6 SRM-HW/HWC 2/99 Detailed Sequence - HWC123, 183, 243, 303 Refer to Figur e 2-1 POWER Line V oltage With the unit at rest (no call from the thermostat ), line voltage will be present: L1 Power 1. Through the L1 b lac k lead to the L1 terminal on the ignition control 2.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-7 SRM-HW/HWC 2/99 9. After 30-second “on” dela y , the circulating air blower rela y energiz es the heat terminal and the circulating air blower is energized. 10. The unit will continue to operate nor mally until the R-W circuit is interr upted.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-8 SRM-HW/HWC 2/99 8. The 24-volt signal will only be supplied to the limit switch circuit through pin 6 of the 6-pin ignition wire har ness and to the pr essure s witch circuit through pin 2 of the 6-pin ignition wire harness.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-9 SRM-HW/HWC 2/99 6. After the 90-second dela y , the ignition control de- energizes the cooling speed rela y and the cir culat- ing air blower stops .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-10 SRM-HW/HWC 2/99 #45008-2 HIGH (BLACK) 64HW MED (BLUE) 51HW HIGH (BLACK) 38HW LOW (RED) LOW (RED) 26HW HEA TING HEA TI NG MODELS EV AP .
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-11 SRM-HW/HWC 2/99 Simplified Sequence - HW (w/UTEC 1097 Boar d) Refer to Figur e 2-2 CALL FOR HEAT 1. The indoor thermostat energizes the R-W circuit, sending a 24-volt signal to the ignition control.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-12 SRM-HW/HWC 2/99 Detailed Sequence - HW (w/UTEC 1097 Boar d) Refer to Figur e 2-2 POWER Line V oltage With the unit at rest (no call from the thermostat ), line voltage will be present: L1 Power 1. Through the L1 b lac k lead to the L1 terminal on the ignition control 2.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-13 SRM-HW/HWC 2/99 12. The gas valve closes immediately as 24V through pin 4 of the 6-pin ignition wire harness is de- energized b y the ignition control .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-14 SRM-HW/HWC 2/99 FAILED FLAME SENSE/TRIAL FOR IGNITION When the pressur e switch closes and a 24-v olt signal is sent to pin 5 of the 6-pin ignition wire har ness , the spark ignition cable terminal and pin 4 of the 6-pin ignition wire harness energize.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-15 SRM-HW/HWC 2/99 BLANK P A GE.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-16 SRM-HW/HWC 2/99 FIGURE 2-3 Connection Diagram #39007D5 HWC122, 182, 242, 302 (w/Fenwal T (w/Fenwal T (w/Fenwal T (w/Fenwal T (w/Fenwal T riton 2461D DSI Ignition.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-17 SRM-HW/HWC 2/99 Detailed Sequence follows CALL FOR COOLING 1. A call for cooling closes the circuit from R to Y and G. 2. A 24-volt signal is sent to b lo wer control board ter minal G and to the compressor contactor .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-18 SRM-HW/HWC 2/99 Detailed Sequence - HWC122, 182, 242, 302 (w/Fenwal T riton 2461D DSI Ignition Contr ol) Refer to Figur e 2-3 POWER Line V oltage When the ser vice disconnect s witch is closed, po wer is sent to the unit (unit in standby , no signal from the thermostat ).
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-19 SRM-HW/HWC 2/99 LIMIT OPENS If the limit switch opens f or an y reason during a call for heat, the follo wing happens: 1.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-20 SRM-HW/HWC 2/99 5. The circulating air blower shuts off appro ximately 90 seconds after G terminal on the blower control board is de-energized (see note belo w). FAN ON Low Voltage 1. When the switch on the thermostat is mo v ed to the “F AN ON” position, a 24-v olt signal is sent to G .
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-21 SRM-HW/HWC 2/99 BLANK P A GE.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-22 SRM-HW/HWC 2/99 #39247D2 HW (Heating Only) (w/Fenwal T riton 2461D DSI Ignition Contr ol) CIRCUITS ENERGI ZED OPERA T ING MODE CIRCUIT HEA T ING R-W LINE VOL T A.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-23 SRM-HW/HWC 2/99 Simplified Sequence - HW (w/Fenwal 2461D Boar d) Refer to Figur e 2-4 CALL FOR HEAT 1. A call for heat closes the circuit betw een R and W on the thermostat. This sends a 24-volt signal to the white wire on the unit.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-24 SRM-HW/HWC 2/99 Detailed Sequence - HW (w/Fenwal T riton 2461D Ignition Contr ol) Refer to Figur e 2-4 POWER Line V oltage When the ser vice disconnect s witch is closed, po wer is sent to the unit (unit in standby , no signal from thermo- stat ).
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-25 SRM-HW/HWC 2/99 9. When W de-energiz es , the gas valve immediately shuts down and the induced dr aft blower also stops after sev er al seconds . 10. The blower control board star ts a countdo wn to blo w er “off ”.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-26 SRM-HW/HWC 2/99 #39007D4 FIGURE 2-5 Connection Diagram HWC122, 182, 242, 302 (w/Fenwal 05-29 Ignition Contr (w/Fenwal 05-29 Ignition Contr (w/Fenwal 05-29 Igniti.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-27 SRM-HW/HWC 2/99 Simplified Sequence - HWC122, 182, 242, 302 (w/Fenwal 05-29 Ignition Contr ol) Refer to Figur e 2-5 CALL FOR COOLING 1. A call for cooling closes the circuit from R to Y and G. 2. A 24-volt signal is sent to b lo wer control board ter minal G and to the compressor contactor .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-28 SRM-HW/HWC 2/99 Detailed Sequence - HWC122, 182, 242, 302 (w/Fenwal 05-29 Ignition Contr ol) Refer to Figur e 2-5 POWER Line V oltage When the ser vice disconnect s witch is closed, po wer is sent to the unit (unit in standby , no signal from the thermostat ).
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-29 SRM-HW/HWC 2/99 9. With W de-energiz ed, the gas valve closes immedi- ately and the induced draft blower stops se v eral seconds later . 10. The blower control board starts a 90-second circulating air blower “off ” dela y .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-30 SRM-HW/HWC 2/99 3. The unit continues cooling as long as both Y and G are energized. When the cooling call is satisfied, the circuit between Y , G and R is interrupted. The contactor immediately opens, interrupting power to the compressor and the outdoor cooling fan .
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-31 SRM-HW/HWC 2/99 BLANK P A GE.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-32 SRM-HW/HWC 2/99 #39247D1 HW (Heating Only) (w/Fenwal 05-29 Ignition Contr ol) C CIRCUI TS ENERGIZED OPERA TI NG MODE CIRCUI T HEA TI NG R-W LINE VOL T AGE - F AC.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-33 SRM-HW/HWC 2/99 Simplified Sequence - HW (w/Fenwal 05-29 Boar d) Refer to Figur e 2-6 CALL FOR HEAT 1. The indoor thermostat calls for heat by energizing the R-W circuit. 2. This sends a 24-volt signal to the ignition control, causing the induced draft blo w er to run.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-34 SRM-HW/HWC 2/99 Detailed Sequence - HW (w/Fenwal 05-29 Ignition Contr ol) Refer to Figur e 2-6 POWER Line V oltage When the ser vice disconnect s witch is closed, po wer is sent to the unit (unit in standby , no signal from the thermostat ).
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-35 SRM-HW/HWC 2/99 8. When the call f or heat is satisfied, the circuit be- tween R and W is interrupted, de-energizing W . 9. With W de-energiz ed, the gas valve closes immedi- ately and the induced draft blower stops se v eral seconds later .
SPECIFICA TIONS Magic-Pak: HW/HWC 2-36 SRM-HW/HWC 2/99 #45005-2 GREEN BLACK BLK M ORANGE VIOLET RED BLUE WHITE RED BLACK BLUE YELLOW WHITE GREEN RED FLAME ROD ELECTRODE 4 5 6 3 2 1 R G W C Y BLACK BLA.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-37 SRM-HW/HWC 2/99 HWC123,183, 243, 303 Low Ambient Model Refer to Figur e 2-7 The low ambient s witch is designed to allo w the opera- tion of the air conditioning unit below the normal operat- ing range.
SPECIFICA TIONS Magic-Pak: HW/HWC 2-38 SRM-HW/HWC 2/99 #44358-2 HWC122, 182, 242, 302 Low Ambient LINE VOL T AGE - F ACTOR Y LINE VOL T AGE - F ACTOR Y ( WHEN USED) LINE VOL T AGE - FIELD LOW V OL T A.
Service Refer ence Manual SEQUENCE OF OPERA TIONS 2-39 SRM-HW/HWC 2/99 The low ambient s witch is designed to allo w the opera- tion of the air conditioning unit below the normal operat- ing range.
Service Refer ence Manual UNIT TEAR DOWN 3-1 SRM-HW/HWC 8/99 Section 3 - Unit T ear Down Heating Section Heat Exchanger Removal ............................ 3-2 Induced Draft Blower Removal ..................... 3-2 Cooling Section Chassis Removal ...
3-2 UNIT TEAR DOWN Magic-Pak: HW/HWC SRM-HW/HWC 8/99 UNIT TEAR DOWN HWC units are comprised of two major sections. The heating section is located in the top half of the unit. It contains the heat e xchanger and the majority of the components associated with the heating function: controls , b urners, s witches, etc.
Service Refer ence Manual UNIT TEAR DOWN 3-3 SRM-HW/HWC 8/99 Figure 3-1 INDUCED DRAFT BLOWER/ COMBUSTION BLOWER HEA TING SECTI ON CONTROL SECTION COOLING SECTI ON HEA T EXCHANGER VESTIBULE P ANEL BURN.
3-4 UNIT TEAR DOWN Magic-Pak: HW/HWC SRM-HW/HWC 8/99 FILLER P ANEL HOLD DOWN SCREWS L1/L2 WIRES 6-PIN LOW VO L T AGE MOLEX PLUG RIGHT SIDE CHASSIS SCREW Figure 3-2 Cooling Section Chassis Removal: The cooling chassis ma y be remov ed from behind the filter access door .
Service Refer ence Manual UNIT TEAR DOWN 3-5 SRM-HW/HWC 8/99 EV APORA TOR BLOWER MO TOR COMPRESSOR EV APORA TOR DRAIN P AN EV APORA TOR EV APORA TOR DRAIN TUBE CONNECTION Figure 3-3 LOW V OL T AGE MOLEX PL UG PERMAGUM SEAL EV APORA TOR DRAIN TUBE CONNECTION DRAIN HOSE (NOT PICTURED) ARMSTRONG P/N 03613A001 17" LONG .
3-6 UNIT TEAR DOWN Magic-Pak: HW/HWC SRM-HW/HWC 8/99 R O T A T I O N MOUNTING SCREWS EV APORA TOR BLOWER ASSEMBL Y CONTROL P ANEL SCREWS CHASSIS BASE PERMAGUM SEAL (BETWEEN BASE RAIL AND CHASSI S BASE) Figure 3-5 Evaporator Blower Assembly Removal: The ev apor ator blo w er assembly is remo v ab le as one complete section.
4-1 Service Reference Manual COMPONENT LOCA TION ILLUSTRA TIONS SRM-HW/HWC 2/99 Section 4 - Component Location Illustrations HW/HWC(3) Unit ................................. 4-2 HW/HWC(2) Unit ................................. 4-3 HW/HWC - Panels ....
4-2 COMPONENT LOCA TION ILLUSTRA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 HW/HWC123,183,243,303 FIGURE 4-1 IGNITI ON/BLOWER CONTROL BOARD (*24) UNITED TECHNOLOGIES 1097-83- 400A/1097-400-I ARMSTRONG P/.
4-3 Service Reference Manual COMPONENT LOCA TION ILLUSTRA TIONS SRM-HW/HWC 2/99 HW/HWC122, 182, 242, 302 FENWAL IGNITION CONTROL - 2 MODELS (*24) FENWAL TRIT ON 2461D 900-227 - ARMSTRONG P/N 43110- 00.
4-4 COMPONENT LOCA TION ILLUSTRA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 SIDE P ANEL ARMSTRONG P/N 38769D001 HEA T EXCHANGER ACCESS P ANEL ARMSTRONG P/N 38782D001 TOP P ANEL ASSEMBL Y ARMSTRONG P/N 03.
4-5 Service Reference Manual COMPONENT LOCA TION ILLUSTRA TIONS SRM-HW/HWC 2/99 HW/HWC Exterior Louver/Grill Panel CONDENSER AIR FLOW OUTLET EXTERIOR UPPER LOUVER P ANEL ARMSTRONG P/N 03545C000 EXTERI.
4-6 COMPONENT LOCA TION ILLUSTRA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 HWC Chassis Assembly EV APORA TOR BLOWER MOT OR (* 69) COMPRESSOR CONT A CTOR (*278) ARMSTRONG P/N 03575C001 CONDENSING FAN SHR.
4-7 Service Reference Manual COMPONENT LOCA TION ILLUSTRA TIONS SRM-HW/HWC 2/99 SEE FIGURE 4-7 FOR CIRCULA TI NG AIR BLOWER COMPONENTS CONDENSER MO TOR (*267) (12-1 8) ARMSTRONG P/N 41282-001 (24-30) .
4-8 COMPONENT LOCA TION ILLUSTRA TIONS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 BLOWER WHEEL (*73) ARMSTRONG P/N 34833B001 10.75" x 4" CIRCULA TI NG AIR BLOWER MO TOR (*69) (12) ARM STRONG P/N 3904.
Service Reference Manual UNIT COMPONENTS 5-1 SRM-HW/HWC 2/99 Section 5 - Unit Components T ransformer ........................................ 5-3 Gas V alves ........................................... 5-4 White-Rodgers 25K49 ........................
5-2 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 HWC Capillar y T ubes .......................... 5-35 Capacitors ......................................... 5-39 Evaporator Blower Motor ................... 5-40 Condenser Fan Motor ................
Service Reference Manual UNIT COMPONENTS 5-3 SRM-HW/HWC 2/99 Unit Components This section provides a brief description of the most impor tant compo- nents within the Magic-P ak HW/HWC units .
5-4 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Gas V alves (*7) Gas V alve Specifications Manuf acturer : White-Rodgers Model: 25K49-120 Armstrong P/N 43108-001 Dimensions: 1.97" W x 5.31" L Nominal Operating Currents: 25V A C/60Hz/.5A Regulator set at 3.
Service Reference Manual UNIT COMPONENTS 5-5 SRM-HW/HWC 2/99 Honeywell 8105 Series Gas V alve Specifications Manuf acturer: Hone yw ell Model: VR8105M8202 Armstrong P/N 44987-001 Dimensions: 2.70" W x 4.75" L Nominal Operating Currents: 25V AC/60Hz/.
5-6 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Blower Contr ol Boar ds (*5) A separate blo w er control board is used in the Magic-P ak HW/HWC models that do not use integrated ignition/b lo wer control boards. Blower control boards from two diff erent manuf acturers are used in these HW and HWC units.
Service Reference Manual UNIT COMPONENTS 5-7 SRM-HW/HWC 2/99 Heatcraft Model IBC-H4C401 Blower Control Board Specifications Manuf acturer: United T echnologies Model: 1010-611 Armstrong P/N 39029B002 Operating V oltage: 18-30V AC 60 Hz 60 Hz P o w er Requirement: 4 V A max.
5-8 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Ignition Contr ols (*24) FENW AL ® ¨ V2 GND FC- CA UTION: HIGH VO L T AGE DISCONNECT W IRING BEFORE SER VICI NG FC+ 24 VAC L1 IND V1 PSW TH Fenw.
Service Reference Manual UNIT COMPONENTS 5-9 SRM-HW/HWC 2/99 Diagnostics (Fenwal T riton 2461D) 1. Diagnostic LED flash rate is 1/4 second “ON”, 1/4 second “OFF” f ollow ed by up to f our seconds “OFF” before repeating the code . 2. Only one code is displa y ed at a time .
5-10 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Fenwal 05-29 DSI G N D V2 T2 S1 V1 P. SW L1 IND FENW AL ® Seri es 05-29 DSI CAUTION HIGH VOL TAG E A UT OMATIC I GNITION SYSTEM FIGURE 5-7 Fenwa.
Service Reference Manual UNIT COMPONENTS 5-11 SRM-HW/HWC 2/99 Integrated Blower/Ignition Contr ol (*24) United T echnologies Model 1097-400-1 The integrated control combines the actions and purposes of the indi- vidual ignition and blo wer control boards f ound on other units.
5-12 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 T ABLE 5-2 UT ech Model 1097 Diagnostic Flash Code United T echnologies Model 1097-400-1 (cont.) Quick Connect T erminal Descriptions 1 24V AC HO.
Service Reference Manual UNIT COMPONENTS 5-13 SRM-HW/HWC 2/99 United T echnologies Model 1097-400-1 (cont.) Heat Mode Pre-purge 30 seconds Inter-purge 30 seconds P ost-purge 5 seconds T rial Time 10 seconds # of T rials 3 Board to reset from lock out after 60 min utes.
5-14 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Induced Draft Blower (*63) The induced draft b lo wer is also ref erred to as a “comb ustion” b lo w er , since its purpose is to establish flow of comb ustion air through the heat e xchanger .
Service Reference Manual UNIT COMPONENTS 5-15 SRM-HW/HWC 2/99 Burners (*34) The Magic-P ak HW and HWC units co v ered in this man ual use a b urner design called the “inshot” type. No adjustment is pro vided f or primary or secondar y air . F or best operation, keep the b urners clean.
5-16 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Flame Carr yover Problems During ignition, the flame must trav el uninterrupted from one burner to the rest of the burners.
Service Reference Manual UNIT COMPONENTS 5-17 SRM-HW/HWC 2/99 Manifold Orifices (*13) Hole Diameter FIGURE 5-13 Manifold Orifice T ABLE 5-3 Manifold Orifice Specifications g n o r t s m r A N / P r e t e m a i D e l o H e z i S l l i r D r e t e m a i D e l o H ) s e h c n i ( 1 0 0 B 0 3 0 9 3k n a l Bk n a l B 2 0 0 B 0 3 0 9 31 50 7 6 0 .
5-18 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Contactor (*278) L1 L2 T1 T2 Open Contact Closed Contact Low V olt age Co il T er m inals FIGURE 5-14 Honeywell Contactor Model R8242A-1008 Contactor Specifications Manuf acturer: Hone ywell Model: R8242A-1008 Armstrong P/N 7535C001 Single-phase, Single-pole, 25 F .
Service Reference Manual UNIT COMPONENTS 5-19 SRM-HW/HWC 2/99 Main (High) Limit Switch (*52) A Normally Closed control that opens if abnor mally high circulating air temperatures occur . It is an automatic reset control. Note: Sev eral diff erent main limit s witches are used.
5-20 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Flame Rollout Switch (*55) A Normally Closed switch that opens when abnor mal temperatures occur in the burner area, caused by a restricted heat exchanger , causing main burner flame to “roll out” into the v estib ule area.
Service Reference Manual UNIT COMPONENTS 5-21 SRM-HW/HWC 2/99 Pr essure Switch (*57) These are Normally Open switches that react to a diff erence in pressure on an internal diaphragm.
5-22 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 T ABLE 5-4 Pressur e Switches Pressur e Switch Problems The negative pressure de v eloped in the comb ustion chamber is directly related to airflow .
Service Reference Manual UNIT COMPONENTS 5-23 SRM-HW/HWC 2/99 Blocked Intake Block ed intak e is any condition that b loc ks or restricts the flow of intake (combustion) air to a point where the pressure f all reaches the calibrated open setting of the pressure s witch.
5-24 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Blocked Flue Block ed flue is an y condition that b loc ks or restricts the flue (vent) pipe to a point where the pressure f all reaches the calibr ated open setting of the pressure switch.
Service Reference Manual UNIT COMPONENTS 5-25 SRM-HW/HWC 2/99 What Is Needed for the T ests • A good general-purpose incline manometer with a range of 0 - 3" W .C . (Dwyer 1227 or equivalent). • Use the par ts list to v erify that the proper pressure s witch is installed in the unit.
5-26 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 A Wor d About the “Switch Closed” V al ue Switch Closed is the pressure at which the contacts close as the induced draft blo w er comes up to speed. It is calculated by adding – 0.1" W .
Service Reference Manual UNIT COMPONENTS 5-27 SRM-HW/HWC 2/99 0 -1" 1" 2" 3" Pressure Swit ch 1/8" T ee Induced Draft Bl o w er BA Incli ne M anom eter = T ee install ed f or .
5-28 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Compr essors (*262) 1 2 3 4 5 6 7 8 9 10 11 12 T ABLE 5-5 Compressor Specifications (continued on next page) l e d o Me p y T r o s s e r p m o C.
Service Reference Manual UNIT COMPONENTS 5-29 SRM-HW/HWC 2/99 1 2 3 4 5 6 7 8 9 10 11 12 e g a t l o Ve s a h PA L RA R L n u R . p a C g n o r t s m r A N / P g n i d n i W R / S . s e R e p y T l i O l i O e g r a h C n o i t c u S e n i L e g r a h c s i D e n i L 0 3 2 / 8 0 21 3 .
5-30 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 A B C D I.D . Copper T ube .(43 - .50 " Suction " Deep) .315 I.D .Copper T ube " Discharge .75 Dia m eter H o le s " C S R Manufactur er: T ecumseh All measurements in inches unless otherwise specified.
Service Reference Manual UNIT COMPONENTS 5-31 SRM-HW/HWC 2/99 T ABLE 5-7 T ecumseh Reciprocating Compressor Specifications Manufacturer: T ecumseh .753"/. 756" I.D . Copper T ube Suction 12.647" 12.753” .378"/. 381" I.D . Copper T ube Discharge 7.
5-32 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Manufactur er: Copeland A B CD .500" I. D . Copper T ube Dischar ge .750" I. D . Copper -Plated Steel T ube Suction 18 Ga. Ther mal Protect or Leads (12.13" Long) 7.50 " (Between Centers of Holes) .
Service Reference Manual UNIT COMPONENTS 5-33 SRM-HW/HWC 2/99 Manufacturer: Copeland C S R T 1 T 3 T 2 9.41 /9.62 "" 7.50 " (T yp.) 7.50 " (T yp.) .750 Dia. (4 Ho le s ) " A B C D .500" I. D . Copper Discharge Fit ting .750" I.
5-34 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Drier -Filters (*301) .314" .317" 4.38" +/– . 13" 1.00 " B - # Holes A - I.D . I.D . FIGURE 5-25 Drier -Filter Armstrong P art Number 39059B001 39059B002 39059B003 A B .
Service Reference Manual UNIT COMPONENTS 5-35 SRM-HW/HWC 2/99 HWC Capillar y T ubes (*256) * All par t numbers pro vided are Armstrong par t numbers. ** See page 5-34 f or drier information. *** See the figures beginning on page 5-36 for detailed dr awings of the capillary tubes.
5-36 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 30° .75" .25" Rad. I.S. T yp . .13" .08" 3.81" Ref. 6.00" 11.89" Ref. 14.00" 1.00 Rad. T yp . " 5302B001 - 2 Req’d 14.88" 12.77" Ref. 1.78" .
Service Reference Manual UNIT COMPONENTS 5-37 SRM-HW/HWC 2/99 30° 4.25" Ref. 6.16" .13" T yp. .12" T yp. 13.13" Ref. 14.74" 3.500" Diameter 1T u r n 3.00" Mandrel 11.00" Ref. 12.91" .25" Rad. I.S.
5-38 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 A - Diameter B - T urns 4.64" 6.76" .75" 1.25" C - D Req’d .75" 2.79" .13" .25" Rad. I.S. T yp. .08" 30° 5.42" 2.844" Diameter 3 T ur ns 53205B025 - 2 Req’d 7.
Service Reference Manual UNIT COMPONENTS 5-39 SRM-HW/HWC 2/99 Capacitors (*271) FIGURE 5-36 Capacitors Dual Single Armstrong P/N Rating V olts MFD T ABLE 5-13 Capacitor Ratings 1 0 0 D 4 1 5 8 35 / 0 .
5-40 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Evaporator Blower Motor - Indoor Blower (*69) • FLA and capacitor ratings ma y v ary . Alw a ys chec k FLA and capacitor ratings on the motor data plate . • Motor diameter - 5.70", shaft size - .
Service Reference Manual UNIT COMPONENTS 5-41 SRM-HW/HWC 2/99 Capacitors-Run (*86) Armstrong P/N Rating V olts MFD T ABLE 5-16 Run Capacitor Ratings 1 0 0 D 1 0 0 4 34 0 7 3 2 0 0 D 1 0 0 4 35 0 7 3 3 0 0 D 1 0 0 4 36 0 7 3 4 0 0 D 1 0 0 4 35 . 70 7 3 5 0 0 D 1 0 0 4 38 0 7 3 6 0 0 D 1 0 0 4 38 0 4 4 7 0 0 D 1 0 0 4 30 10 7 3 8 0 0 D 1 0 0 4 35 .
5-42 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Fan Blades (*268) 18.00 +/ .06 " " AIR FLO W Rota tion Diameter Bore .5002" .5019" 3.79 +/ .09 " " Notes: 1. 26° Pitch, 5 Blades 2. Material: 24 Ga. Galvalume 3.
Service Reference Manual UNIT COMPONENTS 5-43 SRM-HW/HWC 2/99 18.00 +/ .06 " " AIR FLO W Rota tion Diameter Bore .5002" .5019" 3.
5-44 UNIT COMPONENTS Magic-Pak: HW/HWC SRM-HW/HWC 2/99 Low er Grill P anel Ar mstrong P/N 03551D100 Upper Louver P anel Ar mstrong P/N 03545C000 Exterior Grill Panels (Not Listed in the Par ts Lists) Ref er to the Component Location Illustrations section beginning on page 4-1 f or fur ther detail of the e xterior grill panels and other panels.
Service Refer ence Manual INST ALLA TION 6-1 SRM-HW/HWC 8/99 Section 6 - Installation Location .............................................. 6-3 Installing W ith W all Sleeve .................... 6-5 Installing W ithout Wall Sleeve ............... 6-6 Suppor t .
6-2 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Installation and Operation in Extr emely Cold Weather Areas ........................... 6-15.
Service Refer ence Manual INST ALLA TION 6-3 SRM-HW/HWC 8/99 Installation Inf ormation in this section is provided f or the con v enience of the service technician, for the purpose of ev aluating the installation during ser vice and troubleshooting.
6-4 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 If three or more adjacent walls f orm an air shaft with Magic-P ak HW/HWC units facing each other in each w all, the separ ation between opposite walls should be increased b y 20%.
Service Refer ence Manual INST ALLA TION 6-5 SRM-HW/HWC 8/99 Installing W ith a Wall Sleeve FIGURE 6-1 HW/HWC Installation Ref er to the installation instructions pack ed with the wall slee v e and Figure 6-1 for guidance in assemb ly and mounting using a w all slee v e .
6-6 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Installing W ithout a Wall Sleeve Ref er to the f o llowing directions and Figure 6-1 on page 6-5 f or guidance in installing the unit without a wall slee v e: 1. Measure the size of the unit and provide an opening in an outside wall that will accept the unit.
Service Refer ence Manual INST ALLA TION 6-7 SRM-HW/HWC 8/99 Condensate Drain (HWC Models) Install the plastic drain tube (furnished) ov er the 5/8" O .D . fitting w elded to the center of the condensate pan. Connect the other end of the drain tube to the open trap (see Figure 6-2).
6-8 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 The vent system m ust also terminate at least 3 feet abo v e any f orced air inlet within 10 feet of it. These clearances do not apply to the combustion air inlet of the appliance because the combustion air does not enter the air of the b uilding.
Service Refer ence Manual INST ALLA TION 6-9 SRM-HW/HWC 8/99 Removal of Unit fr om Common V enting System When an e xisting furnace is remov ed from a common v enting system serving other appliances, the venting system is likely to be too large to properly vent the remaining attached appliances.
6-10 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Low NO I nser t x FIGURE 6-4 NO x Insert Removal Ne v er use a flame to check f or gas leaks. Explosion causing injury or death may occur .
Service Refer ence Manual INST ALLA TION 6-11 SRM-HW/HWC 8/99 Electrical Connections All wiring must be done in accordance with the National Electrical Code, ANSI/NFP A No. 70 (latest edition); Canadian Electrical Code P art 1, CSA C22.1 (latest edition); or local codes, where they prevail.
6-12 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 T ABLE 6-3 Minimum Cir cuit Ampacity See T able 6-3 and the Specifications section beginning on page 1-1 f or correct wire ampacity f or the cooling chassis required, and siz e the wire accordingly .
Service Refer ence Manual INST ALLA TION 6-13 SRM-HW/HWC 8/99 inside the unit. Make sure that all sides of the duct are flanged ov er to permit removal of the cooling chassis if required. Use a flexib le connec- tion to attach the remainder of the return duct.
6-14 INST ALLA TION Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Adjustments - Cooling Section (HWC models) No adjustments are required or should be attempted regarding any of the components of the cooling chassis. The chassis should be chec k ed to see that none of the wiring is loose or missing.
Service Refer ence Manual INST ALLA TION 6-15 SRM-HW/HWC 8/99 Installation and Operation in Extr emely Cold W eather Ar eas In areas where e xtremely cold (below – 20°F) outdoor temper atures can be e xpected, some additional installation and operating precautions should be taken.
Service Refer ence Manual ACCESSORIES 7-1 SRM-HW/HWC 8/99 Section 7 - Accessories HW/HWC Accessor y Kit Index .............. 7-2 CA-239 Wall Sleeve Kit ................................... 7-3 A242-1 Wall Sleeve Adaptor Kit ...................... 7-7 AL VR42 Architectural Louver Facade .
7-2 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Accessories There are a number of accessories av ailable to increase the perf ormance or versatility of the Armstrong Magic-P ak HW/HWC units. This section provides a general description of each. Note: Complete instructions are packaged with each kit or its components and accessories.
Service Refer ence Manual ACCESSORIES 7-3 SRM-HW/HWC 8/99 CA-239 Wall Sleeve Kit The CA-239 wall slee v e kit is designed to f acilitate the installation of Magic-P ak units b y providing an accurate opening to properly accept a Magic-P ak unit.
7-4 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 T op P anel F ront of Sleev e Suppor t Angle - 8 H oles Squari ng Braces Left Si de P anel Bottom P anel Suppor t Angle - 2 Sides FIGURE 7-1 CA-239 W all Sleeve Kit Assembly T ABLE 7-2 CA-239 P arts List Assembled Wall Slee v e Dimensions: 45" high x 29" wide x 12.
Service Refer ence Manual ACCESSORIES 7-5 SRM-HW/HWC 8/99 Wall Sleeve Installation The wall slee v e can be installed from either the inside or the outside of the building. In any case , proper considerations must be made f or final weather sealing of the w all slee ve and the Magic-P ak unit.
7-6 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Magic-Pak Installation Before installing the Magic-P ak unit in the wall slee v e, it is impor tant to consider the possibility of sound and vibration transmission through the wall.
Service Refer ence Manual ACCESSORIES 7-7 SRM-HW/HWC 8/99 A242-1 Wall Sleeve Adaptor Kit The A242-1 wall slee v e adaptor kit is designed to allow f or the installation of current 43" tall HW/HWC units into 48" tall wall slee v es (CA241 wall sleev e kits).
7-8 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Attachment to HW/HWC After assembling the kit, it is ready to be attached to the top of the HW/ HWC unit. T o attach the kit to the HW/HWC unit: 1. Remov e the two front scre ws (each side) that f asten the top panel side flanges to the side panels on each side of the HW/HWC unit.
Service Refer ence Manual ACCESSORIES 7-9 SRM-HW/HWC 8/99 (2) #8 x ½" Sc rew s in each rear cor ner (2) #8 x ½" Sc rew s in each side Right Si de F ront 1/4" x ¾" Screw ¼".
7-10 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 AL VR42 Ar chitectural Aluminum Louver Facade In many applications, architects and installers will choose to use f acades ov er the front of Magic-P ak units. Often this is done to improv e the appearance of a b uilding.
Service Refer ence Manual ACCESSORIES 7-11 SRM-HW/HWC 8/99 The louver will fit directly against the front of the unit. Howe v er , the lo wer lip of the unit will protrude into the louver . The louv er must be positioned to accommodate the protruding lower lip .
7-12 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 34961A001 Compr essor Vibration Isolator Kit The 34961A001 spring/grommet kit is designed to isolate vibrations common to most compressors aw a y from the base of Magic-P ak units and building w alls.
Service Refer ence Manual ACCESSORIES 7-13 SRM-HW/HWC 8/99 Use of spra y lubricant or liquid soap will aid in the installation of rubber par ts . Compressor belly is rounded and can be “roc k ed” on the belly suppor t. It is easiest to install one spring grommet at a time.
7-14 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 ALPKT389-2 L.P . Gas Conversion Kit The ALPKT389-2 kit contains the follo wing par ts to con vert the 26, 38, 51 and 64HW/HWC series gas fur nace from natural gas to propane gas. For altitudes from 2000 - 4500 feet, a high altitude kit as supplied b y the manuf acturer must be used (see page 7-15).
Service Refer ence Manual ACCESSORIES 7-15 SRM-HW/HWC 8/99 AHAL T390-1 High Altitude Kit The AHAL T390-1 kit contains the following parts to convert the 26, 38, 51 and 64HW/HWC series units to high altitude for natural or propane gas.
7-16 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 x 3600 x = Cubic Feet Per Revolution BTU/HR INPUT # Seconds Per Revolution Heating V alue The heating value of y our gas can be obtained from y our local utility . With proper manifold pressure achie v ed, cycle main burners on and off .
Service Refer ence Manual ACCESSORIES 7-17 SRM-HW/HWC 8/99 A TIMR466-1 Shor t Cycle Pr otector Kit The A TIMR466-1 Shor t Cycle Protector Kit helps guard against compres- sor f ailure due to repeated, shor t inter v al on/off cycles . It is also ref erred to as the Nuisance Blow er Operation Repair Kit.
7-18 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 ADAPT420-2 Chassis Conversion Kit The AD APT420-2 kit w as designed to retrofit an HWC122, 182, 242 or 302 chassis onto a cabinet originally equipped with an HWC12, 18, 24 or 30 chassis. This kit cannot be used to replace an HWC181, 241 or 301.
Service Refer ence Manual ACCESSORIES 7-19 SRM-HW/HWC 8/99 Fenwal T riton Ignition Contr ol Kit This kit enables the F enw al “T riton” local sense, one-hour retry , direct spark ignition (DSI) control to be used as a ser vice par ts replacement f or earlier versions of F enwal DSI controls used on HW/HWC models .
7-20 ACCESSORIES Magic-Pak: HW/HWC SRM-HW/HWC 8/99 TL109 Burner T ray Kit The TL109 Burner T ray Kit is designed f or use in HW/HWC’ s that were originally equipped with single por t inshot burners.
Service Refer ence Manual ACCESSORIES 7-21 SRM-HW/HWC 8/99 Discharge Mu ffler Discharge Line t o Condenser Coil FIGURE 7-6 AMUFFKT494-1 Kit Discharge Muffler Installation AMUFFKT494-1 Dischar ge Muffler Kit In the ev ent that during operation an unacceptab le noise occurs, a muffler kit (AMUFFKT494-1) ma y be installed in the discharge line*.
8-1 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS Section 8 - Par ts Lists HWC123, 183, 243, 303-1 .................. 8-2 HWC182, 242-11 ................................ 8-5 HWC122, 242-10 ................................ 8-7 HWC182-9 ........
8-2 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC303A-1 A First find Model #. ------------------------------------------------ > 64HWC303A-1 (*) Then match Ser vice Le v el f or desired part .
8-3 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303A-1 A First find Model #. ------------------------------------------------ > 64HWC303A-1 (*) Then match Ser vice Le v el f or desired part .
8-4 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC303A-1 A First find Model #. ------------------------------------------------ > 64HWC303A-1 (*) Then match Ser vice Le v el f or desired part .
8-5 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 38HWC242A-11 A First find Model #. -------------------------------------------------------------- > 38HWC242A-11 (*) Then match Ser vice Le v el f or desired part .
8-6 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 38HWC242A-11 A First find Model #. -------------------------------------------------------------- > 38HWC242A-11 (*) Then match Ser vice Le v el f or desired par t.
8-7 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS HWC122-242A-10 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 38HWC242A-10 A First find Model #. -------------------------------------------------------------- > 38HWC242A-10 (*) Then match Ser vice Le v el f or desired part .
8-8 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 HWC122-242A-10 (cont.) REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 38HWC242A-10 A First find Model #. -------------------------------------------------------------- > 38HWC242A-10 (*) Then match Ser vice Le v el f or desired part .
8-9 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS HWC122-242A-10 (cont.) REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 38HWC242A-10 A First find Model #. -------------------------------------------------------------- > 38HWC242A-10 (*) Then match Ser vice Le v el f or desired par t.
8-10 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC182A-9 A First find Model #. -------------------------------------------------------------- > 64HWC182A-9 (*) Then match Ser vice Le v el f or desired part .
8-11 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 64HWC182A-9 A First find Model #. -------------------------------------------------------------- > 64HWC182A-9 (*) Then match Ser vice Le v el f or desired part .
8-12 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC302A-9 A First find Model #. -------------------------------------------------------------- > 64HWC302A-9 (*) Then match Ser vice Le v el f or desired part .
8-13 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC302A-9 A First find Model #. -------------------------------------------------------------- > 64HWC302A-9 (*) Then match Ser vice Le v el f or desired part .
8-14 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-8 A First find Model #. ------------------------------------------------ > 64HWC302-8 (*) Then match Ser vice Le v el f or desired par t.
8-15 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-8 A First find Model #. ------------------------------------------------ > 64HWC302-8 (*) Then match Ser vice Le v el f or desired part .
8-16 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-8 A First find Model #. ------------------------------------------------ > 64HWC302-8 (*) Then match Ser vice Le v el f or desired part .
8-17 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC182-6 A First find Model #. -------------------------------------------------------------- > 64HWC182-6 (*) Then match Ser vice Le v el f or desired part .
8-18 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC182-6 A First find Model #. -------------------------------------------------------------- > 64HWC182-6 (*) Then match Ser vice Le v el f or desired part .
8-19 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-5 A First find Model #. ------------------------------------------------ > 64HWC302-5 (*) Then match Ser vice Le v el f or desired part .
8-20 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC302-5 A First find Model #. ------------------------------------------------ > 64HWC302-5 (*) Then match Ser vice Le v el f or desired part .
8-21 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-5 A First find Model #. ------------------------------------------------ > 64HWC302-5 (*) Then match Ser vice Le v el f or desired part .
8-22 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 38HWC182-4 A First find Model #. -------------------------------------------------------------- > 38HWC182-4 (*) Then match Ser vice Le v el f or desired part .
8-23 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 38HWC182-4 A First find Model #. -------------------------------------------------------------- > 38HWC182-4 (*) Then match Ser vice Le v el f or desired par t.
8-24 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 38HWC182-4 A First find Model #. -------------------------------------------------------------- > 38HWC182-4 (*) Then match Ser vice Le v el f or desired part .
8-25 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-3 A First find Model #. ------------------------------------------------ > 64HWC302-3 (*) Then match Ser vice Le v el f or desired part .
8-26 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-3 A First find Model #. ------------------------------------------------ > 64HWC302-3 (*) Then match Ser vice Le v el f or desired part .
8-27 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC302-3 A First find Model #. ------------------------------------------------ > 64HWC302-3 (*) Then match Ser vice Le v el f or desired part .
8-28 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC182-2 A First find Model #. -------------------------------------------------------------- > 64HWC182-2 (*) Then match Ser vice Le v el f or desired part .
8-29 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 64HWC182-2 A First find Model #. -------------------------------------------------------------- > 64HWC182-2 (*) Then match Ser vice Le v el f or desired par t.
8-30 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-1 A First find Model #. ------------------------------------------------ > 64HWC302-1 (*) Then match Ser vice Le v el f or desired part .
8-31 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC302-1 A First find Model #. ------------------------------------------------ > 64HWC302-1 (*) Then match Ser vice Le v el f or desired part .
8-32 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC302-1 A First find Model #. ------------------------------------------------ > 64HWC302-1 (*) Then match Ser vice Le v el f or desired part .
8-33 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REVISED 1-20-98 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HW -1 A First find Model #. -------------------------------------------------------------- > 64HW -1 (*) Then match Ser vice Le v el f or desired part .
8-34 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REVISED 1-20-98 HW -1 (cont.) REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HW -1 A First find Model #. -------------------------------------------------------------- > 64HW -1 (*) Then match Ser vice Le v el f or desired part .
8-35 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS HW A-9 REVISED 4-26-99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 64HW A-9 A First find Model #. -------------------------------------------------------------- > 64HW A-9 (*) Then match Ser vice Le v el f or desired part .
8-36 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 HW A-9 (cont.) REVISED 4-26-99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Level. 64HW A-9 A First find Model #. -------------------------------------------------------------- > 64HW A-9 (*) Then match Ser vice Le v el f or desired part .
8-37 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS HWC3-S-1 REVISED 4-26-99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303SA-1 A First find Model #. ------------------------------------------------ > 64HWC303SA-1 (*) Then match Ser vice Le v el f or desired part .
8-38 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303SA-1 A First find Model #. ------------------------------------------------ > 64HWC303SA-1 (*) Then match Ser vice Le v el f or desired part .
8-39 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303SA-1 A First find Model #. ------------------------------------------------ > 64HWC303SA-1 (*) Then match Ser vice Le v el f or desired part .
8-40 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 HWC3-H-1 REVISED 4-26-99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303HA-1 A First find Model #. ------------------------------------------------ > 64HWC303HA-1 (*) Then match Ser vice Le v el f or desired part .
8-41 SRM-HW/HWC 8/99 Service Reference Manual P ARTS LISTS REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Service Lev el. 64HWC303HA-1 A First find Model #. ------------------------------------------------ > 64HWC303HA-1 (*) Then match Ser vice Le v el f or desired part .
8-42 P ARTS LISTS MAGIC-P AK: HW/HWC SRM-HW/HWC 8/99 REC STOCKING P ART T O SELECT P AR T # Last letter of the Model # is the Ser vice Le v el. 64HWC303HA-1 A First find Model #. ------------------------------------------------ > 64HWC303HA-1 (*) Then match Ser vice Le v el f or desired part .
Service Refer ence Manual TROUBLESHOOTING 9-1 SRM-HW/HWC 8/99 Section 9 - T r oubleshooting/ Per for mance/ Char ge W eights T roubleshooting ................................... 9-2 Compr essor Checkout ................................ 9-2 Capacitor Checkout .
9-2 TROUBLESHOOTING Magic-Pak: HW/HWC SRM-HW/HWC 8/99 T r oubleshooting Compr essor Checkout The objective of this section is to help in diagnosing compressor prob- lems. It presents a ser ies of tests that should be conducting bef ore a determination on the condition of the compressor is made.
Service Refer ence Manual TROUBLESHOOTING 9-3 SRM-HW/HWC 8/99 2. Set an ohm meter to the low est possib le setting. On a note pad, write the follo wing: “C to ground”, “S to g round” and “R to ground.
9-4 TROUBLESHOOTING Magic-Pak: HW/HWC SRM-HW/HWC 8/99 When the resistance of “C to S” is added to the resistance of “C to R”, the combination is the total resistance of the entire motor windings circuit. 2. Compare the total to the reading tak en between “S to R.
Service Refer ence Manual TROUBLESHOOTING 9-5 SRM-HW/HWC 8/99 ov erload protector has opened. Before the compressor can be con- demned as having a b urned out star t or run winding, it must be deter- mined that the ov erload switch is in f act closed.
9-6 TROUBLESHOOTING Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Capacitor Checkout Before starting the check out of the capacitor , it is impor tant to understand what a capacitor is, how it w orks and what its function is in relation to a motor .
Service Refer ence Manual TROUBLESHOOTING 9-7 SRM-HW/HWC 8/99 The f ollowing inf or mation is f ound on a capacitor: the MFD (microf ar ad rating) and the working voltage . Compare this to the rating plate on the motor or the inf ormation provided with the unit.
9-8 TROUBLESHOOTING Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Before starting the test, take a reading of the line v oltage at the outlet that will be used. Double chec k the connections , making sure that the amp meter is on. Plug the test leads into the wall outlet.
Service Refer ence Manual TROUBLESHOOTING 9-9 SRM-HW/HWC 8/99 Per formance Per formance Checkout HW/HWC chassis come with a pre-charged chassis assembly . The chassis assembly is designed in a w a y that the unit ma y be run indepen- dently of the HWC unit.
9-10 TROUBLESHOOTING Magic-Pak: HW/HWC SRM-HW/HWC 8/99 Perfor mance T ests (Chassis Installed in Unit) - cont. T otal Air V ol. (CFM) Enter . DB/WB Suction Pressure Suction Te m p . Liquid Te m p . Suction Pressure Suction Te m p . Liquid Te m p . Suction Pressure Suction Te m p .
Service Refer ence Manual TROUBLESHOOTING 9-11 SRM-HW/HWC 8/99 Perfor mance T ests (Chassis Bench T ested) T ABLE 9-6 95° Ambient T emperature Chassis Bench T est T ABLE 9-5 70 - 80° Ambient T emperature Chassis Bench T est s i s s a h C l e d o M t n e i b m A .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Armstrong World Industries 242 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Armstrong World Industries 242 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Armstrong World Industries 242 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Armstrong World Industries 242 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Armstrong World Industries 242, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Armstrong World Industries 242.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Armstrong World Industries 242. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Armstrong World Industries 242 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.