This is an unv ented gas-fi red heater . It uses air (o xygen) from the room in which it is installed. Provisions f or adequate combustion and v entilation air must be provided.
2 43D0122 CONTENTS IMPOR T ANT SAFETY INFORMA TION ............................................................................................................... 3 GETTING ST AR TED ....................................................................
43D0122 3 8. CARBON MONO XIDE POISONING: Early signs of carbon monoxide poisoning are similar to the fl u with headaches, dizziness and/or nausea. If you hav e these signs, obtain fresh air immediately . Hav e the heater serviced as it may not be operating properly .
4 43D0122 IMPOR T ANT SAFETY INFORMA TION This appliance may be installed in an after - market, permanently located, manufactured (mobile) home, wher e not prohibited by local codes. This appliance is only f or use with the type of gas indicated on the rating plate.
43D0122 5 MAKE SURE Y OU HA VE RECEIVED ALL P ARTS: Check your packing list to verify that all listed parts ha ve been recei ved. Y ou should hav e the following: • Un vented gas log grate/burner as.
6 43D0122 NA TURAL GAS Milli-V olt Pressure Regulator Pressure Setting: 3.5" w .c. Pilot Regulator: 3.5" w .c. Gas Inlet Pressure: Max. 10 1/2" w . c. Min. 5" w .c. PR ODUCT FEA TURES AND SPECIFICA TIONS PROP ANE/LPG Note: An external regulator is required to reduce supply pressure to a maxim um of 13" w .
43D0122 7 GENERAL INST ALLA TION INFORMA TION CODES Adhere to all local codes or , in their absence, the latest edition of THE N A TIONAL FUEL GAS CODE ANSI Z223.1 or NFP A54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway Ne w Y ork, NY 10018 or National Fire Pr otection Association, Inc.
8 43D0122 W H WA RNING If the area in which the heater ma y be operated is smaller than that defi ned as an unconfi ned space or if the building is of un usually tight construction, pro vide adequate combustion and ventilation air b y one of the methods described in the National Fuel Gas Code, ANSI Z223.
43D0122 9 WA RNING A C B WA RNING Model A B C DST30 36" 20 1 / 4 " 21 1 / 2 " FIREPLA CE AND HEAR TH DIMENSIONS Use manufacturer's installation and clearance requirements as defi ned in their manual.
10 43D0122 WA RNING Height of Restriction (X) Minimum Depth of Fireplace/Firebo x No restr iction 20 1 / 4 " 0.5 to 1.5" 24" Greater than 1 1 / 2 " to 3" 26" Greater than 3: ANY BARRIER GREA TER THAN THREE INCHES (3") PLA CED IN FRONT OF THE GAS LOG SET IS NO T RECOMMENDED BY THE MANUF A CTURER.
43D0122 11 36" 36" 42" 1 3 / 4 " WA RNING The dimensions sho wn in Figures 4 thr ough 10 and defined in the fireplace manufacturer's instructions are minim um clearances to maintain when installing this heater .
12 43D0122 Measure this distance Heater in Fireplace or Firebo x Heat Resistant Material Figure 5 - Measuring Heat Resistant Material IMPORT ANT : 1. If installing unit into an unv ented fi rebox, minimum required clearances listed in the fi rebox installation manual must be met.
43D0122 13 Heater in Fireplace or Firebo x 8" or More of Heat Resistant Material Hood CLEARANCES and HEIGHT REQUIREMENTS Figure 6 - Measuring Heat Resistant Material for Mantel Heat resistant mat.
14 43D0122 Minimum of 8" Heat Resistant Material Mantel Hood 2 1 / 2 " 13" 6" 7" 17" 4" Heater in Fireplace or Firebo x Heat Resistant Material 10" or less 12" min.
43D0122 15 Heater in Fireplace or Firebo x 5" Minimum Combustib le Material 14" Minimum Heater in Fireplace or Firebo x Combustib le Material This Distance Ma y Now Be Less than 5" FLOO.
16 43D0122 Damper Stop Damper WA RNING Figure 11 - Damper Stop Installation. (See W ARNING at top of next pa g e .) FIREPLA CE PREP ARA TION BEFORE FULL Y INST ALLING THE UNIT : • T urn OFF the gas supply to the fi replace or fi rebox. • Seal any fresh air vents and/or ash clean-out doors located on the fl oor or wall of the fi replace.
43D0122 17 WA RNING WA RNING ASSEMBL Y PROCEDURE: 1. Center the gas log unit in the fi replace or fi rebox. Make certain the front feet of the grate sit inside the front edge of the fi replace or fi rebox. 2. Anchor holes are located on the right and left sides of the unit.
18 43D0122 CA UTION Pipe Coupling To Heater V alve Gas Supply Inlet Use new b lack iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets h ydrogen sulfi de limits, and where permitted by local codes.
43D0122 19 T est P or t “OUT” WA RNING Connecting directl y to an unregulated pr opane/LPG tank can cause an explosion. CHECKING GAS PRESSURE The heater gas inlet connection is a female 3 / 8 " NPT at the v alve. The inlet connection is on the right side of unit when facing the control.
20 43D0122 CA UTION Label all wires prior to disconnection when servicing controls. Wiring error s can cause improper and dangerous operation. V erify proper operation after servicing. ELECTRICAL WIRING (MILLI-V OL T) The milli-volt v alve is a self-po wered combination gas control THA T DOES NO T REQUIRE 110 V AC T O OPERA TE.
43D0122 21 ELECTRICAL WIRING (MILLI-V OL T) A. COMPLETE MILLIV OL T SYSTEM CHECK (“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON) a. If the reading is more than 175 milli-volts and the automatic v alve still does not come on, replace the control.
22 43D0122 Pins DO NO T sprinkle v olcanic rock on the logs or around the pilot or the main b urner . This may cause sooting. Place vo lcanic roc k only on the fl oor of the fi replace . During initial operation of the ne w heater , burning logs will give off a paper b urning smell and orang e fl ames will be present.
43D0122 23 FLAME APPEARANCE Flames from the pilot, fr ont and rear burner should be visually c hecked as soon as the heater is installed. In addition, periodically check the fl ames visually during operation. CHECKING THE PILO T FLAME The pilot fl ame must al ways be present when the heater is in operation.
24 43D0122 In normal operation at full rate after 15 minutes, the follo wing fl ame appearances should be obser ved: Figure 20 - Correct Appearance of Flames The flames should be yello w and extend 3"-4" abov e the log top surfaces. The yello w flames should not contact the logs.
43D0122 25 WA RNING Figure 21 - Location of Piezo Ignitor , Control Knobs and Switc h on Milli-V olt Unit If y ou do not follow these instruction e xactl y , a fi re or explosion ma y result causing property damage, personal injury or loss of life. FOR Y OUR SAFETY READ BEFORE LIGHTING A.
26 43D0122 PILOT LO ON OF F HI OPERA TING INSTRUCTIONS MILLI-V OL T CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutof f valv e is fully open. 3. This gas log set is equipped with an ignition de vice (piezo) which automatically lights the pilot.
43D0122 27 T urn off heater and allo w to cool before c leaning. Disconnect electrical power bef ore cleaning or servicing. WA RNING OPERA TING INSTRUCTIONS AND CLEANING AND SER VICING MA TCH LIGHTING INSTR UCTIONS 1. Remov e any items necessary for easy access to the pilot (for example: logs, screens, etc.
28 43D0122 OBSER VED PROBLEM When ignitor button is pr essed, there is no spark at ODS/pilot. A ppliance pr oduces unwanted odors. Appliance shuts off during use. Gas odor ev en when control knob is in OFF position. When ignitor button is pr essed, there is spark at ODS pilot, b ut no ignition.
43D0122 29 If the gas quality is bad, your pilot ma y not stay lit, the burners ma y produce soot and the heater may bac kfi re when lit. If the gas quality or pressure is low , contact y our local gas supplier immediately . WA RNING OBSER VED PROBLEM ODS/pilot lights, but f la me goes out when control knob is re leased.
30 43D0122 1 2 9 4 11 6 12 7 8 5 3 10 ILLUSTRA TED P ARTS BREAKDO WN WA RNING F ailure to position the parts in accor dance with these diagrams or failure to use only par ts specifically appro ved with this appliance may result in pr oper ty damage or personal injury .
43D0122 31 REPLA CEMENT P ARTS LIST REPLA CEMENT P AR TS ARE A V AILABLE THROUGH Y OUR RET AILER. Accessories Flex Connector Flexcon 30 All Models Wall Switch Kit MVWS Milli-volt only W all Ther mosta.
September 2001 P/N 43D0122 • Rev . 1 MONESSEN HEAR TH SYSTEMS LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The follo wing components are warranted for life to the original owner , subject of proof of purchase: Firebox, Combustion Chamber , Heat Exchanger, Grate, and Stainless Steel Burners.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Monessen Hearth dst30 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Monessen Hearth dst30 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Monessen Hearth dst30 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Monessen Hearth dst30 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Monessen Hearth dst30, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Monessen Hearth dst30.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Monessen Hearth dst30. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Monessen Hearth dst30 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.