Installation Instructions T ype C Boilers G.C.N: 41-116-04 LEA VE THESE INSTRUCTIONS WITH THE END-USER Countr y of destination: GB.
This manual is an integr al and essential par t of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel.
3 1.1 G ENERAL I NSTRUCTIONS Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance.
4 The technical inf ormation and instr uctions provided herein below are intended f or the installer so that the unit ma y be installed correctly and saf ely .
F or saf ety pur poses, ha ve a competent person carefully check the electrical system in the proper ty , as the manufacturer will not be held liab le for damage caused b y the f ailure to ear th the appliance properly or b y anomalies in the supply of power .
6 The boiler operates with alternating current, as indicated in the technical inf ormation table in section 7, where the maximum absorbed power is also indicated. Make sure that the connections f or the neutral and liv e wires correspond to the indications in the diagram.
7 C ENTRAL H EA TING Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the f ollowing notes are giv en for general guidance . P IPE W ORK : Copper tubing to BS EN 1057:1996 is recommended f or water pipes . Jointing should be either with capillar y soldered or compression fittings.
8 Ø 60/100 mm F IG . 2.6 A BC D E F G J K HI L G F The boiler is designed to be connected to a coaxial flue discharge system. 2.9 F LUE C ONNECTIONS F LUE S YSTEM The provision f or satisfactory flue ter mination must be made in accordance with BS 5440-1.
Exhaust T ype C12 (xx) C32 (xx) C42 (xx) Restrictor ø 44 mm L min = 0.5 m L max = 1 m Maximum Extension Exhaust/Air L = 5 m Risk of Condensation Forming Coaxial Systems ø 60/100 Piping not insulated ø 44 restrictor NO restrictor NONE NONE Piping insulated ø 44 restrictor NO restrictor NONE NONE T ABLE 2.
2.11 E LECTRICAL D IA GRAM 10 F IG . 2.12 Legend: A - On/Off Switch B - On/Off L.E.D . C - Heating Switch D - Heating L.E.D . E - Reset Button F - Ignition F ailure (Lock out) L.
11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L EGEND : 1. F an 2. Main heat exchanger 3. Overheat thermostat 4. Bur ner 5. Ignition electrodes 6. Detection electrode 7. Regulation ther mostat 8. F rost ther mostat 9. Gas valv e 10. Pump pressure s witch 11.
12 3. D .H.W . ST ORA GE CYLINDER The microSYSTEM can be connected to a storage cylinder (both open-v ented and unv ented) for the production of domestic hot w ater (D .H.W .). Cylinders of diff erent capacities can be used depending on site requirements (see T ABLE 3.
13 T echnical Data Capacity Coil C.H.W . D .H.W . Max Heating Heat Ioss Surface Flow/rate Flo w/rate Output MODEL It. m 2 m 3 /h It/h kW kWh/24h Contract STI 125 Indirect 125 0.75 0.5 194 11.3 2 1 266 15.5 2 340 19.8 Comfort STI 125 Indirect 125 0.75 0.
14 MTS (GB) Limited suppor t the initiative. Within the inf or mation pack you will find a cop y of the logbook. It is impor tant that this is completed in the presence of your customer , the y are shown ho w to use it, and it is signed by them.
B 4 5 In order to access the inside of the boiler , it is necessar y to unscrew the f astening screws “A” of the control panel located on the lower part of the panel itself. The control panel mov es downward and when pulled f orward rotates on two lateral hinges .
16 The flue connector has two aper tures, readings can be tak en for the temperature of the comb ustion by-products and of the combustion air , as well as of the concentr ations of O 2 and CO 2 , etc. . T o access these intakes it is necessary to unscrew the front screw and remo ve the metal plate with sealing gasket.
The boiler is fitted with the f ollowing de vices (see section 4.2 for ref erences). 1 - I GNITION F AILURE : This indicates ignition f ailure when a flame is not detected within 7 seconds of star ting an ignition sequence. The L.E.D . “F” will illuminate to signal the shutdown status .
18 The boiler can be con ver ted to use either methane (natural) gas (G20) or LPG (G30 - G31) by an A uthorised Service Centre . The operations that must be perf or med are the follo wing: 1. Replace the jets on the main burner (see table in section 5); 2.
19 It is recommended that the follo wing inspections be carried out on the boiler at least once a year: 1 - Check the seals f or the water connections; replace any f aulty seals. 2 - Check the gas seals; replace any faulty gas seals . 3 - Visual check of the entire unit.
Manuf acturer : Merloni T ermoSanitari SpA - Italy Commercial subsidiar y: MTS (GB) LIMITED MTS Building Hughenden A venue High Wycombe Bucks HP13 5FT T elephone: (01494) 755600 F ax: (01494) 459775 Internet: http://www .mtsgb.ltd.uk E-mail: inf o@mtsgb.
Servicing Instructions T ype C Boilers G.C.N: 41-116-04 LEA VE THESE INSTRUCTIONS WITH THE END-USER Countr y of destination: GB.
2 1. SER VICING INSTR UCTIONS 1.1 R EPLACEMENT OF P AR TS 1.2 T O G AIN G ENERAL A CCESS - Removing the front panel - Removing the sealed chamber front co ver - Removing the side panels 1.
2. The control panel mov es downward and when pulled f orward, rotates on two lateral hinges; the panel sta ys in a semi- horizontal position, which allows access to the inner parts of the boiler (F IG .
4 1.2.2 Removing the sealed c hamber front cover 1. Remov e the screws “C” (F IG . 1.6); 2. Lift the sealed chamber front cov er from the locating pins (F IG . 1.7). F IG . 1.6 C C F IG . 1.7 1.2.3 Removing the side panels 1. Remov e the four scre ws “D” for each side panel (F IG .
1.3.3 Removing the electr odes Bef ore carr ying out this procedure, unscrew and slide the burner forw ard (see previous section). 1. Remov e r ubber gask et “G” (F IG . 1.12); 2. T o remove the detection electrode disconnect the cab le at its connection point close to the P .
6 3. Remov e screw “H” ( F IG . 1.14); 4. Gently slide the electrode downw ard (F IG . 1.15) . T o replace, repeat the steps in rev erse order , paying par ticular attention to the follo wing: a -.
1. Disconnect electrical connections “N” and silicon pipe “O” (F IG .1.22); 2. Remov e screw “P” and remove the f an collar clamp “Q” (F IG .1.23); 3. Remov e screws “R” (F IG .1.24); 4. Remov e fan and mounting plate (F IG .1.25).
8 1.4 S ER VICING AND R EMO V AL OF THE G AS V AL VE 1.4.1 Setting the gas pressures 1 2 3 A B C F D Setting the maximum po wer of the boiler 1. Check that the supply pressure to the gas v alve is a minim um of 20 mbar f or natural gas. T urn off the gas suppl y at the isolation point under the boiler 2.
9 1.22 20 8.3 2.9 2.9 ---- ----- ----- 0.91 Kg/h ------ Kg/h 22.9 mbar ---- mbar 28 mbar 0.90 Kg/h ------ Kg/h 29.5 mbar ---- mbar 37 mbar 6 x 1.30 6 x 0.77 6 x 0.77 Gas restrictor ¿ 10 RFFI T ABLE A TB016A 6. Remov e the pipe from the pressure gauge and connect screw “ C ” to the pressure outlet in order to seal off the gas.
10 F IG . 1.28 F IG . 1.29 U V V 1.4.3 Removing the gas v alve Impor tant! Before removing the gas v alve , ensure the gas supply is tur ned off . 1. Disconnect all the cables from the solenoid and modureg; 2. Remov e the spar k generator (see pre vious section); 3.
11 1. 5. 2 Removing the safety v alve 1. Loosen nut “ Y ” (F IG . 1.33); 2. Disconnect the discharge pipe work from below the boiler ; 3. Unscrew and remo ve the v alve. 1.5.3 Removing the automatic air vent 1. Unscrew v alve top “ Z ” (F IG .
12 1.5.4 Removing the pump 1. Remov e the U-clips “ A1 ” and “ B1 ” (F IG . 1.36); 2. Remov e the retaining clip “ C1 ” (F IG . 1.37); 3. Release the nut “ D1 ” (F IG . 1.38); 4. Remov e the pipe “ E1 ” (F IG . 1.39); 5. Remov e the screw “ F1 ” (F IG .
13 1.5.6 Removing the e xpansion vessel 1. Release nuts “ H1 ” and remov e the gas pipe (F IG . 1.44); 2. Release nut “ I1 ” (F IG . 1.45); 3. Remov e lock-nut “ J1 ” (F IG . 1.46); 4. Remov e the expansion v essel (F IG . 1.47). 1.5.5 Removing the pressure gauge 1.
14 1.5.6 Removing the o verheat thermostat 1. Disconnect the ov erheat ther mostat electrical connections “ K1 ” (F IG . 1.48); 2. Then remov e the ther mostat from its mounting by releasing the securing clip (F IG . 1.49). 1.5.7 Removing the fr ost thermostat 1.
15 1.6.2 Removing the P .C.B.s 1. Isolate electricity; 2. Remov e the screws “ O1 ” (F IG . 1.56); 3. Separate the f acia panel from the rear of the control panel; 4. Unplug all electrical connections from the P .C .B. and remov e the screws “ P1 ” and remove the P .
16 B063 2. F A UL T FINDING P RELIMINAR Y CHECKS MAKE SURE THA T : IS THE SUPPL Y L.E.D. ILLUMINATED? IS THE L.E.D. ILLUMINA TED? NO NO NO YES NO 1 - C HECK THE FUSES 2 - C HECK THERE IS POWER SUPPLIED TO THE P .C.B. S 3 - C HECK / REPLACE THE P. C . B .
17 B063 IS THE PUMP RUNNING? NO YES PO WER T O THE PUMP? 1 - C HECK THE OPERA TION OF THE PUMP 2 - R ELEASE /R EPLA CE THE PUMP 1 - C HECK THE PUMP CABLE 2- C HECK /R EPLA CE P.
18 B063 IS THE BURNER ALIGHT? YES NO YES YES BOILER WORKING? YES NO NO NO NO YES 5- C HECK /R EPLACE P .C . B . (CBM2) 4-C HECK /R EPLACE P .C .B. (CBM2) 4 - C HECK /R EPLA CE P .
19 B063 3. ELECTRICAL DIA GRAMS SE011A L EGEND : A - On/Off Switch B - On/Off L.E.D . C - Heating Switch D - Heating L.E.D . E - Reset Button F - Ignition F ailure (Lock out) L.
20 B063 SF008A.
21 B063 MODELS CHARACTERISTICS SERIAL NO: VALIDITY REF. MICROSYSTEM 10 RFFI METHANE 2320021100001 A MICROSYSTEM 10 RFFI LPG 2320021100001 B MICROSYSTEM 15 RFFI METHANE 2320021100001 C MICROSYSTEM 15 R.
22 B063 998616 573521 573520 570760 998612 573528 998447 569390 998627 999542 574279 999474 998809 999476 998424 998836 999578 999499 999245 998517 998484 997182 999538 998624 998622 998623 998893 999481 999686 999479 999685 998433 998434 999501 950030 999486 998487 998488 998644 998643 998738 998961 998716 998717 Key no.
23 B063 NO TES.
23 99 84 1582 000 - Manuf acturer : Merloni T ermoSanitari SpA - Italy Commercial subsidiar y: MTS (GB) LIMITED MTS Building Hughenden A venue High Wycombe Bucks HP13 5FT T elephone: (01494) 755600 F ax: (01494) 459775 Inter net: http://www .mtsgb .ltd.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Ariston 41-116-04 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Ariston 41-116-04 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Ariston 41-116-04 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Ariston 41-116-04 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Ariston 41-116-04, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Ariston 41-116-04.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Ariston 41-116-04. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Ariston 41-116-04 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.