TECHNICAL MANUAL Manual No.'10•SR-T-091D INVERTER RESIDENTIAL AIR CONDITIONERS (Split system, air to air heat pump type) DRAFT Wall mounted type SRK50Z J -S SRK20ZJX-S SRK 25ZJX-S SRK 35ZJX-S S.
- 1 - '10 • SR-T -091D CONTENTS 1. SPECIFICATIONS ......................................................................................... 2 (1) Wall mounted type (SRK) ......................................................................... 2 (1) Indoor units (1) Indoor units .
- 2 - '10 • SR-T -091D 1. SPECIFICATIONS (1) Wall mounted type (SRK) B R W A000Z225 Model Item SRK50ZJ-S Indoor unit SRK50ZJ-S Outdoor unit SRC50ZJ-S Cooling capacity (1) W 5000 (1600 (Min.) ~ 5500 (Max.)) Heating capacity (1) W 5800 (1600 (Min.
- 3 - '10 • SR-T -091D B R W A000Z229 Model Item SRK20ZJX-S Indoor unit SRK20ZJX-S Outdoor unit SRC20ZJX-S Cooling capacity (1) W 2000 (900 (Min.) ~ 3100 (Max.)) Heating capacity (1) W 2500 (900 (Min.) ~ 4300 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 4 - '10 • SR-T -091D B R W A000Z229 Model Item SRK25ZJX-S Indoor unit SRK25ZJX-S Outdoor unit SRC25ZJX-S Cooling capacity (1) W 2550 (900 (Min.) ~ 3200 (Max.)) Heating capacity (1) W 3130 (900 (Min.) ~ 4700 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 5 - '10 • SR-T -091D B R W A000Z229 Model Item SRK35ZJX-S Indoor unit SRK35ZJX-S Outdoor unit SRC35ZJX-S Cooling capacity (1) W 3500 (900 (Min.) ~ 4100 (Max.)) Heating capacity (1) W 4300 (900 (Min.) ~ 5100 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 6 - '10 • SR-T -091D B R W A000Z229 Model Item SRK50ZJX-S Indoor unit SRK50ZJX-S Outdoor unit SRC50ZIX-S Cooling capacity (1) W 5000 (700 (Min.) ~ 6200 (Max.)) Heating capacity (1) W 6000 (700 (Min.) ~ 8800 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 1.
- 7 - '10 • SR-T -091D B R W A000Z229 Model Item SRK60ZJX-S Indoor unit SRK60ZJX-S Outdoor unit SRC60ZIX-S Cooling capacity (1) W 6000 (800 (Min.) ~ 6800 (Max.)) Heating capacity (1) W 6800 (800 (Min.) ~ 9700 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 1.
- 8 - '10 • SR-T -091D (2) Floor standing type (SRF) A R WB000Z053 Model Item SRF25ZJX-S Indoor unit SRF25ZJX-S Outdoor unit SRC25ZJX-S Cooling capacity (1) W 2500 (900 (Min.) ~ 3200 (Max.)) Heating capacity (1) W 3400 (900 (Min.) ~ 4700 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 9 - '10 • SR-T -091D A R WB000Z053 Model Item SRF35ZJX-S Indoor unit SRF35ZJX-S Outdoor unit SRC35ZJX-S Cooling capacity (1) W 3500 (900 (Min.) ~ 4100 (Max.)) Heating capacity (1) W 4500 (900 (Min.) ~ 5100 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 10 - '10 • SR-T -091D A R WB000Z053 Model Item SRF50ZJX-S Indoor unit SRF50ZJX-S Outdoor unit SRC50ZIX-S Cooling capacity (1) W 5000 (700 (Min.) ~ 5500 (Max.)) Heating capacity (1) W 6000 (700 (Min.) ~ 7000 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 1.
- 1 1 - '10 • SR-T -091D A R W A000Z231 Model Item SRR25ZJ-S Indoor unit SRR25ZJ-S Outdoor unit SRC25ZJX-S Cooling capacity (1) W 2500 ( 900 (Min.) ~ 3200 (Max.)) Heating capacity (1) W 3400 ( 900 (Min.) ~ 4700 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 0.
- 12 - '10 • SR-T -091D A R W A000Z231 Model Item SRR35ZJ-S Indoor unit SRR35ZJ-S Outdoor unit SRC35ZJX-S Cooling capacity (1) W 3500 ( 900 (Min.) ~ 4100 (Max.)) Heating capacity (1) W 4200 ( 900 (Min.) ~ 5100 (Max.)) Power supply 1 Phase, 220 ~ 240 V, 50Hz Operation data (1) Power consumption Cooling kW 1.
- 13 - '10 • SR-T -091D Model Item FDTC25VD Indoor unit FDTC25VD Outdoor unit SRC25ZJX-S Panel TC-PSA-25W-E Power source 220/230/240V ~ 50Hz Operation data Cooling Heating Nominal capacity kW 2.55 [ 0.9 (Min.) ~ 3.2 (Max.)] 3.45 [ 0.9 (Min.) ~ 4.
- 14 - '10 • SR-T -091D Model Item FDTC35VD Indoor unit FDTC35VD Outdoor unit SRC35ZJX-S Panel TC-PSA-25W-E Power source 220/230/240V ~ 50Hz Operation data Cooling Heating Nominal capacity kW 3.6 [ 0.9 (Min.) ~ 4.1 (Max.)] 4.25 [ 0.9 (Min.) ~ 5.
- 15 - '10 • SR-T -091D 2. EXTERIOR DIMENSIONS (1) Indoor units Model SRK50ZJ-S Space for installation and service when viewing from the front Wired - remote controller 㧔 Option 㧕 Notes 㧔 1 㧕 The model name label is attached ޓޓ ޓ on the underside of the panel.
- 16 - '10 • SR-T -091D Models SRK20ZJX -S, 25ZJX-S, 35ZJX-S , 50ZJX-S, 60ZJX-S G F Hole on wall for right rear piping Hole on wall for left rear piping Gas piping Outlet for wiring Drain hose Liquid piping F E C D B Symbol A 㧔Ǿ 65 㧕 VP16 Ǿ 6.
- 17 - '10 • SR-T -091D (b) Floor standing type (SRF) Models SRF25ZJX-S, 35ZJX-S, 50ZJX-S 600 Unit:mm Hole on wall for right rear piping Hole on wall for left rear piping Gas piping Drain hose Liquid piping F E C D B Symbol A 㧔Ǿ 65 㧕 VP16 Ǿ 6.
- 18 - '10 • SR-T -091D (c) Ceiling concealed type (SRR) Models SRR25ZJ-S, 35ZJ-S A RJD000Z502 8- φ 2.8 Holes for tapping scre ws (φ 4 ) 455 253 325.
- 19 - '10 • SR-T -091D (d) Ceiling cassette-4way compact type (FDTC) Models FDTC25VD, 35VD D G F C B Hole for wiring Suspension bolts Drain piping Liquid piping ( M10 or M8 ) VP20 ( I.D.20,O.D.26 ) Note ( 2 ) φ 6.35 ( 1 / 4" ) ( Flare ) Gas piping A Symbol φ 9.
- 20 - '10 • SR-T -091D (2) Outdoor units Model SRC50ZJ-S RCT000Z005 L2 Intake Outlet Intake L3 L1 Minimum installation space Service space ( ) L4 L2 L3 L4 L1 100 100 250 Open I I I Open 250 80 280 I I I 280 Open 80 75 Examples of Dimensions installation I V 180 Open 80 Open φ 12.
- 21 - '10 • SR-T -091D A RCV000Z007 Models SRC20ZJX-S, 25ZJX-S, 35ZJX-S L2 Intake Outlet Intake L3 L1 Minimum installation space Service space ( ) L4 L2 L3 L4 L1 100 100 250 Open I I I O.
- 22 - '10 • SR-T -091D Models SRC50ZIX-S, 60ZIX-S RCT000Z004 Terminal block L2 Intake Outlet Intake L3 L1 L4 Service space ( ) Minimum installation space Notes ( 1 ) It must not be surrounded by walls on the four sides. ( 2 ) The unit must be fixed with anchor bolts.
- 23 - '10 • SR-T -091D (3) Remote controller (a) Wireless remote controller Models SRK, SRF, SRR 60 17 150 Unit: mm 60 17.3 150 ٨ The wireiess remote controller in the following figure shows for the SRK-50ZJ-S type.
- 24 - '10 • SR-T -091D (b) Wired remote controller (option parts) PJZ000Z274 TEMP ON/OFF 48 غ 120 L C D Wall surface Wiring Electrical box 䋨 Not included 䋩 19 Wiring specifications Exposed mounting 23 46 11.5 11 Remote control outline 120 45 83.
- 25 - '10 • SR-T -091D 250V 3.15A PRINTED CNF CNE CNX CNG 4 CNU 1 3 6 5 ̪ ̪ 35,50 CNY M M M 5 5 U 2 8 2 t o CNS CNM M 5 TO OUTDOOR S/N J L G 1 CIRCUIT BOARD INTERFACE KIT RD BK WH Y BL WIREL.
- 26 - '10 • SR-T -091D Models SRK20ZJX -S, 25ZJX-S, 35ZJX-S , 50ZJX-S, 60ZJX-S 250V F G 3.15A S 㧛 N Va CNU CNS INTERFACE KIT SC-BIKN-E CNG CNE DISPLAY WIRELESS RECEIVER J CNF U M HEAT 1 3 4 .
- 27 - '10 • SR-T -091D (b) Floor standing type (SRF) Models SRF25ZJX-S, 35ZJX-S, 50ZJX-S Color Marks Blue Black BK Red BL RD White WH Yellow 㧛 Green Y 㧛 G Yellow YE Color Mark Heat exch.
- 28 - '10 • SR-T -091D (c) Ceiling concealed type (SRR) Models SRR25ZJ-S, 35ZJ-S Item Meaning of Marks Description Item Description Color Marks Mark Color Mark Color T TO OUTDOOR UNIT RECEIVER BL YE BK RD WH CNG DISPLAY WIRELESS CNY CNE BK BK PRINTED CIRCUIT BOARD F 250V 3.
- 29 - '10 • SR-T -091D (d) Ceiling cassette-4way compact type (FDTC) Models FDTC25VD, 35VD B PJA003Z340 Control PCB Power PCB XR1 XR2 XR3 XR4 XR5 ( Remote operation input:volt-free contact .
- 30 - '10 • SR-T -091D (2) Outdoor units Model SRC50ZJ-S A R WC000Z228 Color RD Mark Orange OR Yellow / Green Y / G Black BK Brown BR Yellow Y White WH Red Description Item Connector CNEEV.
- 31 - '10 • SR-T -091D A R WC000Z227 Models SRC20ZJX-S, 25ZJX-S, 35ZJX-S Color RD Mark Orange OR Yellow / Green Y / G Black BK Yellow Y White WH Red Description Item Connector Electric exp.
- 32 - '10 • SR-T -091D A R WC000Z214 Models SRC50ZIX-S, 60ZIX-S Color RD Mark Orange OR Yellow / Green Y / G Black BK Brown BR Yellow Y White WH Red Description Item Connector CNEEV ~ 20.
DATA BOOK Manual No. '09 • P A C - DB -136 DRAFT INVER TER RESIDE NTIAL AIR CONDI TIONERS Air-Conditioning & Refrigeration Systems Headquarters 16-5, 2-chome, Kounan, Minato-ku, T okyo, 108-8215, Japan Fax : (03) 6716-5926 Copyright MITSUBISHI HEA VY INDUSTRIES, L TD.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mitsubishi Electronics SRK507J-S è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mitsubishi Electronics SRK507J-S - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mitsubishi Electronics SRK507J-S imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mitsubishi Electronics SRK507J-S ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mitsubishi Electronics SRK507J-S, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mitsubishi Electronics SRK507J-S.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mitsubishi Electronics SRK507J-S. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mitsubishi Electronics SRK507J-S insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.