Manuale d’uso / di manutenzione del prodotto GB-50ADA-J del fabbricante Mitsubishi Electronics
Vai alla pagina of 16
Air-conditioner Network System Centralized Controller AG-150A GB-50ADA-A GB-50ADA-J I n s t r u c t i o n B o o k (Web browser for User) Contents 1 Introduction ............................................................................. 1 1-1 Terms Used in this Manual .
1 1 Introduction Special features of Mitsubishi Electric Corporation’s “Centrali zed Controller AG-150A,” “Centralized Controller GB-50ADA-A,” and “Centralize d Controller GB-50ADA-J” are that a PC conn ected to a LAN can be used to monitor the operation condition of air co nditioners and perfo rm air conditioner operations.
2 2 Setting the Operating Environment PC settings and web brow ser settings required for usi ng a web browser to monitor air cond itioner units and perform operations are explaine d in the following pages. 2-1 Setting the PC IP Address Set an IP address on the PC that enable s AG-150A to connect via a web bro wser.
3 (4) In the [Internet Protocol (TCP/IP) P roperties] dialog, cli ck [Use the following IP address] and enter the IP address (for exa mple, “192.168.1.101”) that you want to set in the IP address field. You normally set [255.255.255. 0] as the subnet mask.
4 2-2 Setting the Web Browser Necessary web browse r settings mu st be performed to enable the web browser to connect to the AG-150A . Note: The settings and screen images used as examples in this manual ar e base d on Internet Explorer 6.
5 2-2-3 Connecting to the Internet using a proxy server (Using an existing LAN) If the PC you use for monitoring air c onditioners and p erforming operations is going to acce ss the Internet via proxy.
6 2-3 Setting the Java Execution Environment When using Java Plug-in versi on 1.6.0_ 10 or later, ma ke the following environment settings (not required for version 1.6.0_09 or earlier). Note: The setting samples and screenshots used in this m anual are those of Java Plug-in version 1.
7 3 Performing Operations Text below explains how t o connect to the AG -150A and how to monitor and adjust the operation co ndition of air conditioners. Follow the directio ns given here when performing operatio ns. Note: If the AG-150A is restarted due to a power interruption et c.
8 3-1-2 Encrypting the communication data and login on the AG-150A AG-150A can encrypt communication d ata using HTTPS (SSL). When connecting the AG-150A to the LAN that can be accessed by the general public, it is recommended that the following settings be made so that the units are monitore d and controlled on the encrypted Web page.
9 (4) If the security alert has not been disabled, after enter ing the web address an d hitting the Enter (Return ) key, a security alert message will alert aski ng if you want to proceed. This is bec ause the AG-150A uses the self-authentication system.
10 3-2 Checking the Operation Condition When you login correctly using the Login Screen, the sc reen used to monitor the operation condition s of air conditioner and general e quipment and hot water supply groups will appea r. If you wish to operate, click the group icon to switch to the operation screen.
11 Item Description Group icon (2) Ventilator (Lossnay) group operatio n co ndition Note: When connecting multiple AG-150A controllers by connecting an Expansion Controller to th e system, “Schedule set” and “Energy saving” will be di splayed only on the AG-150A controller that is executing these functions.
12 3-3 Performing the Operations Text below explains how to perfo rm air conditione r or general equipment or hot water supply operations. 3-3-1 Performing the operations that target one group When you click on a group icon in the operation co ndition monitoring screen, the operation screen for that group will appear.
13 Item Description Interlocked ventilator ON/OFF *1 Click [ON] or [OFF] to switch inte rlocked ventilator ON or OFF. Note: For groups that are not c onnected to an interl ocked ventilator, the items related to interlocked ventilators are not displayed.
.
This product is designed and inte nded for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • E.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mitsubishi Electronics GB-50ADA-J è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mitsubishi Electronics GB-50ADA-J - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mitsubishi Electronics GB-50ADA-J imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mitsubishi Electronics GB-50ADA-J ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mitsubishi Electronics GB-50ADA-J, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mitsubishi Electronics GB-50ADA-J.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mitsubishi Electronics GB-50ADA-J. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mitsubishi Electronics GB-50ADA-J insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.