Manuale d’uso / di manutenzione del prodotto 1DM100 del fabbricante Mitsubishi Electronics
Vai alla pagina of 30
A975GOT-TBA/TBD ( -B ) A970GOT-TBA/TBD ( -B ) A970GOT-SBA/SBD A970GOT-LBA/LBD A960GOT-EBA/EBD User’s Manual (Hardware) Thank you for buy ing the MELSEC-GOT Series. Prior to use, please read bot h this manual and detailed manual thoroughly and familiarize y ourself with the product.
A -1 DA NGER CA UTION z SAFETY PRECAUTIONS z (Read these precauti ons before using.) When using this equipment, thoroughly r ead this manual. Also pay careful attention to safety and handle the module properly . These precautions apply only to this equipment.
A -2 [DESIGN PRECA UTIO NS] DA NGER z Do not use the GOT as the warni ng device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the devic e that display s and outputs serious warning.
A -3 [MOUNTING PRECA U TIONS] CA UTION z The GOT should be used in the env ironment given in the general specifications of this user's manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
A -4 [WIRING PRECA UTIO NS] CA UTION z Please make sure to ground FG te rminal, LG terminal, and protective ground terminal of the GOT power supply unit by apply ing Class D Grounding (Class 3 Grounding Method) or higher which is used ex clusively for the GOT.
A -5 [STA RTUP/MA INTENA NCE PRECA UTIONS] DA NGER z When power is on, do not touch the terminals. Doing so can cause an elec tric shock or malfunction. z Before starting cleaning or terminal screw retightening, alway s switch off the power ex ternally in all phases.
A -6 [BA CKLIGHT CHA NGING PRECA UTIONS] DA NGER z Before changing the backlight, alway s switch off the GOT pow er externally in all phases (when the GOT is connec ted to the bus, the PLC CPU pow er must also be switched off ex terna lly in all phases) and remove the GOT main unit from the enclosure.
A -7 Rev isions *The manual number is given on the bottom right of the top cover. Print Date *Manual Number Revi sion Jan., 1999 IB(NA)- 80032-A First edi tion Jun., 1999 IB(NA)- 80032-B Partial corre ction Section 5.1 Partial addi tion Section 3.2, Section 3.
A -8 CONTENTS 1. Overv i ew ....................................................................................................... 1 1.1 Packing List .............................................................................................. 1 2. System Conf igurati on .
1 1. Ov erv i ew This user's manual describes the system configuration, s pecifications, part names, handling and outline dimensions of the A975GOT/A970GOT/A960GOT Graphic operation terminal (Ref erred to as GOT, hereafter). The following GOT ty pes are available.
2 2. Sy stem Configura tion The overall configuration of the GOT is shown below . GOT Communic ation module, Co mmunicat ion board *1 Drawing softwa re Opti on Memo ry board Flash PC card *1 Exte rnal.
3 3. Specifications 3.1 General specifications Item Specifications Display section 0 to 40 ° C *1 Operating ambient temperature Other than di splay section 0 to 55 ° C Storage ambi ent temperature -.
4 3.2 Performan ce specifications Specificat ions Item A975GOT - TBA(-B ) A975GOT - TBD(-B ) A970GOT - TBA(-B ) A970GOT - TBD(-B ) A970GOT - SBA A970GOT - SBD A970GOT -LBA A970GOT -LBD A960GOT -EBA A9.
5 *4: GT W orks2 and GT Desi gner2, are suppor ted from the first versi on (Version1.00A). *5: The specifications differ depending on the ver sion of GOT (hardware v ersion, function ver sion).
6 3.3 Pow er supply speci fications Specifications Item A975GOT-TBA(- B) A970GOT-TBA(- B) A970GOT-SBA A970GOT-LBA A960GOT-EBA A975GOT-TBD(- B) A970GOT-TBD(- B) A970GOT-SBD A970GOT-LBD A960GOT-EBD Input power supply vol ta ge 100AC to 240V ( + 10%,-15%) 24VDC ( + 25%,-20%) Input frequency [H z] 50/60 ± 3 - Input max.
7 4. Name of the Parts 1) 2) 3 ) 4) 5) 6) 7) 13) 12) 11) 1 0) 9) 8) 17) 17) 17) 17) 18) W hen 9) is rem oved 14) 16) 15) No. Name Description 1 ) Display section Shows the screen 2 ) Reset button Used.
8 5. Handling 5.1 Handling instructions When mounting the main unit to a control box or the like, set the display section as shown below . When the temperature inside the enclosure is 40 to 55 ° C or less, the mounting angle should be in the range 60 to 105 degrees.
9 (2) Mounting position When mounting the GOT, the following clearances must be left from the other device. (100mm (3.94 i nch) or more) A Plate thickness wit hin 2mm to 4mm (0 .08i nch t o 0. 16i nch) Ot her device (80mm ( 3.15 inch) or more) (50m m (1.
10 (3) Mounting method (a) Put the GOT main unit into the panel opening, w ith its front face first. (b) Mount the GOT in the following f our locations at its top and bottom. (Top) (Bottom) Mounting Position Mounting position (c) How to mount and fix the mounting fixture is giv en below.
11 5.3 Wiring diagram (1) 100AC to 240V DC12/24V LL +- I N P U T 100-240VA C (LG) (FG) 12/24VDC 0.1A L L RUN OUTPU T + - (2) DC24V I N P U T 2 4 V D C (LG) (FG) 12/24 VDC 0.
12 5.4 The Precautions on the Wiring DA NGER z Completely turn off the externally supplied power used in the sy stem when installing or placing wiring.
13 (1) Power supply wiring y Separate the GOT's power supply line from the lines for I/O dev ices and power dev ices as shown below. When there is much noise, connect an insulation transformer.
14 (2) Grounding y For grounding, perform the following: Use a dedicated grounding wire as far as possible. (Grounding resistance of 100 or less.) y When a dedicated grounding cannot be performed, use (2) Common Grounding shown below . Also, be sure to take noise c ountermeasures other than grounding.
15 (b) An example of common grounding GOT CN1A CN1B CN2 CN3 FG LG Connection cabl e Pane l groun din g Grounding t erminal block Use a grou nding wire as thi ck and shor t as possible. FG FG LG Power equipment (Servo, etc.) * Apply single-point grounding for one sy stem.
16 POINT (1) Use the thickest possible (max. 2 mm 2 (14 AWG)) wires for the 100/200 VAC and 24 VDC power cables. Be sure to tw ist these wires starting at the connection terminals. To prevent a short-circuit should any screw s loosen, use solderless te rminals with insulation sleev es.
17 5.7 Precautions for back light replacement Use the following back lights for t he GOT that includes this manual. Type Model Replacement back light A975GOT-TBA (Hardware v ersion D (JAN,1998) or lat.
18 A pp endices A ppendi x 1 Outline dimensi on draw i ng E A D C B I H F M L K J GG Unit: mm (inch) Item A B C D E F G H I J K L M A 975GOT, A 970GOT 297 (11.70) 208 (8.20) 235 (9.26) 229 (9.02) 288 (11.35) 199 (7.84) 10 (0.40) 46 (1.81) 40 (1.58) 6 (0.
19 A ppendi x 2 Depth dimension for w h en mounting each ty pe of module (1) A97*GOT Installed communicati on module A [mm] (inch) B [mm] (inch) A9GT-QBUSS, A9GT-BUSS 40 (1.57) 85 (3.35) A9GT-QBUS2S, A9GT-BUS2S 62 (2.44) 85 (3.35) A9GT-BUSSU, A9GT-BUS2SU 74 (2.
20 MEMO.
Warranty Mitsubishi will not be held liable for damage c aused by factors found not to be the cause of Mitsubishi ; machine damage or lost pr ofits caused by faults in the Mitsubishi products; damage,.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mitsubishi Electronics 1DM100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mitsubishi Electronics 1DM100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mitsubishi Electronics 1DM100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mitsubishi Electronics 1DM100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mitsubishi Electronics 1DM100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mitsubishi Electronics 1DM100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mitsubishi Electronics 1DM100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mitsubishi Electronics 1DM100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.