Manuale d’uso / di manutenzione del prodotto Entrust del fabbricante Minute Man
Vai alla pagina of 25
User's Manual Entrust Series UPS.
1 © Copyright 2007 1 . Introduction 2 2 . Controls and Indicators 6 3. Installation 7 4. Operation 10 5 . T roubleshooting 12 6 . Replacing the Battery 13 7 .
2 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS ! English Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service.
3 W ARNING: Risk of Electrical Shock. Hazardous live p arts inside these power supplies are energized from the battery even when the AC input is disconnected. CAUTION! T o de-energize the outputs of the UPS: 1. If the UPS is on press and release the On/Off Button.
4 English After removing your UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored.
5 English Life Support Policy As a general policy , we do not recommend the use of any of our products in life support applications where failure or malfunction of the product can be reason- ably expected to cause failure of the life support device or to significantly affect its safety or effectiveness.
6 English 1. On/Off Button. 2. AC Mode (Green) LED. 3. On Battery (Y ellow) LED. 4. Bad Battery/Overload/Fault (Red) LED. 5. Input power cord. 6. Surge Only output power receptacles. 7. The USB communications port is for UPS monitoring and control. 8.
7 English INST ALLA TION PLACEMENT This UPS series is intended to be install in a temperature controlled environment that is free of conductive contaminants. Avoid locations near heating devices, water or excessive humidity , or where the UPS is exposed to direct sunlight.
8 English CONNECTING THE BA TTERIES (QUALIFIED SERVICE PERSONNEL ONL Y) Please read all of the W ARNINGS and CAUTIONS before attempting to connect the batteries. 1. Remove the UPS from the shipping box and set on a table or a bench top. 2. Remove the retaining screws from the bottom of the front panel of the UPS.
9 English CHARGING THE BA TTER Y The UPS will charge the internal batteries whenever the UPS is connected to an AC source and there is an acceptable AC voltage present (90 - 150V AC). It is recommended that the UPS's batteries be charged for a minimum of 4 hours before use.
10 English SYSTEM OVERVIEW This Line-Interactive UPS protects computers, internetworking, and telecom- munications equipment from blackouts, brownouts, overvoltages, and surges. The A VR function continuously corrects the volt ages, in-between the brownout and overvoltage transfer point s (90 - 150V AC), to a safe usable level.
11 English USB COMMUNICA TIONS PORT The USB communications protocol is HID. The HID USB driver comes stan- dard in the Windows OS. Simply plug the USB cable into the UPS and the computer then follow the prompts on the screen.
12 English Possible Cause Symptom What T o Do Press and release the On/Off button to start UPS On/Off/ button not pressed UPS will not turn on Reset circuit breaker by pressing the plunger back in.
13 English REPLACING THE BA TTER Y W ARNING! This UPS contains potentially hazardous voltages. Do not at- tempt to disassemble the UPS beyond the battery replacement procedure. This UPS contains no user serviceable parts. Re- pairs and battery replacement must be performed by QUALIFIED SERVICE PERSONNEL ONL Y .
14 English BA TTER Y REPLACEMENT PROCEDURE PLEASE READ THE CAUTIONS AND W ARNINGS BEFORE A TTEMPTING TO REPLACE THE BA TTERIES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system.
15 English FIG . 1 FIG . 2 FIG . 3: ETR500 FIG . 3: ETR700 FIG . 3: ETR1000/1500.
16 English IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. V erify there are no circuit breakers tripped.
17 English 120V A C 500V A 300W 1000V A 600W 700V A 420W Protection W aveform Type Over-Current, Short-Circuit Protected and Latching Shutdown Simulated Sine Wave (S tep Wave) Frequency 50/60Hz, +/-0.
18 English BA TTER Y SYSTEM T ypical Recharge T ime T ypical Battery Life Battery: Quantity/Rating 3-5 years, depending on discharge cycles and ambient temp 1-12V5Ah 2-12V7Ah 8-hours from total discha.
19 English Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials (excluding the batteries) or workmanship for a period of three years from the date of purchase.
20 English A1. DECLARA TION OF CONFORMITY Application of Council Directive(s): 89/336/EEC, 73/23/EEC S tandard(s) to which Conformity is declared: Manufacturer’s Name: Para Systems, Inc.
21 English Notes:.
22 English Notes:.
.
Para Systems, Inc. 1455 Lemay Dr . Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-901 1 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000295 R1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Minute Man Entrust è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Minute Man Entrust - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Minute Man Entrust imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Minute Man Entrust ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Minute Man Entrust, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Minute Man Entrust.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Minute Man Entrust. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Minute Man Entrust insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.