Manuale d’uso / di manutenzione del prodotto RAVL42 del fabbricante Minolta
Vai alla pagina of 40
Report No.050-S-08c-5 INST ALLA TION AND OPERA TION MANUAL - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
2 FOR YOUR SAFETY do not install or operate your Ravelle™ 42 gas fireplace without first reading and und erst andi ng this ma nual . Any insta llat ion or ope rat ion of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazard - ous.
3 CO NG RA TU LA TI ON S ! When you purchased your new gas fireplace, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for ever y 1,000 feet to maintain the proper ratio of gas to air . Improper orifice sizing may result in damage and unsafe conditions.
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. (NYC MEA Approval #138-07-E) Installation of these fireplaces are approved for installation in New Y ork City in the US state of New Y ork.
6 Features Installation Options Residential Vented vertical and horizontal Manufactured (mobile) home Natural gas (NG) or propane (LP) Bedrooms Optional wall-mounted or remote thermostat Ductable for greater heat distribution Venting This fireplace can be vented with Security™ Secure Vent™ pipe*.
Figure 1 Figure 2 7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Pr e pa ri ng Y ou r R av e ll e™ 4 2 F ir e pl ac e For I n st al la tio n Read all instructions before beginning your installation.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Framing Dimensions The dimensions given on this page are minimum framing distances neces- sary to maintain safe clearances between the Ravelle™ 42 gas fireplace and combustible materials.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 4 18-9/16 (471) 14 (356) 44-1/2 (1130) 51-1/4 (1302) 29-3/4 (756) 20-3/4 (527) 47-3/4 (1213) 35-1/2 (902) 2 (51) 34 (864) 41 (1041) 38-1/.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Base of Fireplace One Inch Space Fireplace Face Raised Platform Nailing Plate Raised Installations The fireplace may be raised by building a platform of sufficient strength to support the fireplace and pipe.
Figure 8 11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. The screws should be driven through the cement board into the outer metal skin of the fireplace.
Figure 9 Figure 10 Figure 15 Figure 14 Figure 13 Figure 12 The fireplace face dimensions are: Arch Face Adjustment prior to arched face installation: The corners of the 1” (25mm) reveal around the fireplace opening need to be adjusted prior to installing an arched face (see Figures 13 and 14 ) .
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 2. Bracket C in the diagram below is installed on the face during the face assembly (see instructions included with face). The captive screws D on this bracket should be screwed into captive nuts E on the fireplace.
Application: The Ravelle™ 42 gas fireplace, has been tested and listed as a direct vent heater system by OMNI-T est Laboratories, Portland, Oregon. and is recommended for use with Security™ Secure Vent™ pipe. IMPORT ANT : • Read all instructions carefully before starting the installation.
15 Vent Parts List - Horizontal Direct vent pipe by Security™ or Simpson Dura-V ent may be used with the Ravelle™ 42 gas fireplace. Please see the lists below to verify the components available from each direct vent pipe manufacturer .
Vent Considerations T wist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide into the four entr y slots on the male ends (see Figure 17 ) .
Figure 18 17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Horizontal Vent Installation IMPORT ANT NOTES: 1. All Ravelle™ 42 gas fireplaces horizontally terminated vent installations use 8”x 5” Security™ Secure Vent™ or Simpson Dura-Vent GS direct-vent pipe.
18 Flue Restrictors The flue restrictor settings shown in Figures 22 and 23 are for typical installations and may need to be adjusted from standard to take into acco unt othe r varia bles in the instal latio n to achiev e proper combus tion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Vertical T erminations (Use 6-5/8” Direct-Vent Pipe) The shaded areas in the diagram below show all allowable combinations of straight vertical and offset to vertical (maximum four 45º elbows or two 90º elbows) vent configurations with vertical terminations.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Exterior Horizontal Vent T ermination Clearance Requirements V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C * S e e I t e m D i n th e T e x t B e l o w .
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Log Installation Instructions If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a color - less, odorless, toxic gas.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Electrical Connections: * Th e breake r suppl ying ele ctric ity to the fireplac e must be turn ed off at the electrical panel before any connections are made at the fireplace. * The wire supplying the fireplace should be a minimum of 14 gage and provide 120 Volts at 60 hz.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fuel T ype Inlet Pressure Manifold Pressure Desired Minimum Maximum On Hi Fire On Lo Fire Natural Gas 7" WC 5" WC 10.5" WC 3.5" WC 1.7" WC LP Gas 11" WC 11 " W C 13" WC 11" WC 5.
24 Increasing Efficiency and Hot Air Movement A number of different options are available to the homeowner to maximize the heat output and air movement to different rooms in the house.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Forced Air Heating Installation Hot air can be drawn off the Ravelle™ 42 gas fireplace and moved into other rooms of the house with the forced air heating system. This system can be purchased as an option from your Lennox Hearth Products dealer (part #75134).
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. The fan box may be located in the wall, floor , or ceiling. Ceiling and Wall Mounting: 1) Fasten the two angled brackets to the side of the face box with the screws provided (see A below). Floor Mounting: 1.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Expanded V iew Bend T abs Under Cover Plate Flapper Plate Starter Ring Starter Ring Adapter Duct Assembly: The duct has zero clearance to combustibles. 1. Remove the cover plate from the top of the fireplace.
28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Wiring of the Forced Air System Continued: 2. Remove the cover over the electrical box at the right lower rear of the fireplace. Run sheathed wire from the fireplace electrical box to the switch box and from the switch box to the fan box.
29 Operating Instructions Pre-Lighting Checklist Be sure to check these items before the initial lighting of the fireplace: c The fireplace gas label corresponds to the gas supply available - that is "natural gas" for natural gas or "LP gas" for Propane gas.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. TO TURN OFF GAS TO APPLIANCE 1. T urn off the "ON/OFF" rocker switch and/or thermostat (if installed) to its lowest setting. 2. T urn off electric power to the appliance if ser vice is to be performed.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Air Shutter Adjustment The Ravelle™ 42 gas fireplace has an air shutter control lever located at the upper left corner beneath the firebox (see Figure 46 ) . The lever is linked to the primar y air shutter on the main burner .
32 Operating Options Y our Ravelle™ 42 gas fireplace comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round rocker switch located behind the lower door of the fireplace’ s face.
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Vent Pipe Maintenance Conduct an inspection of the venting system semi-annually . Recom- mended areas to inspect are as follows: 1. Check areas of the venting system which are exposed to the elements for corrosion.
34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Opening and Removing Door CAUTION: Do not open the glass door when the fireplace is burning. Let the unit cool before opening the door . At the top of the glass door are two spring-loaded latches.
35 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Log Set Installation on Page 21 . If there is soot in one specific location, the rockwool below this location needs to be adjusted.
36 Co ntr ols H4 6 35 DW T K W al l T he rm ost at , D ig it al H0 2 51 R CL -S T A T Re m ot e Co ntr ol , R CL -S T A T , De lu xe Th e rm o- st a t DC (ref. form #750129M) Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts.
37 Fa ce Kit s Ar che d (ref. form #775253M) Ca t. No. Mo del De sc ri pti on 75 2 94 AI F 42 -B LK Bl a ck F ac e, Ar c he d 75 2 96 AI F4 2- G OL D Go l d Fa ce , A rc h ed 75 2 95 A I F4 2- NK L Br.
38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. IGN DATE OF MANUFACTURE 200 8 20 10 201 1 200 9 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC C A U T I O N : HO T W H IL E I N O PE R ATIO N . D O NOT TOU CH . S E VE R E B UR N S M A Y R ES U LT .
39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION: YO UR LE NNOX ™ GA S A PPLI ANCE MUST A L WA YS BE OP ERA TED WI TH G LASS DOO R IN PLAC E. STO P! R ead the s afet y in forma tion abo ve be fore pro ceedi ng. 1. Op en t he l ow er a cc es s do or .
Printed in U.S.A. © 2007 Lennox Hearth Products P/N 775,219M REV . C 06/2009 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Minolta RAVL42 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Minolta RAVL42 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Minolta RAVL42 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Minolta RAVL42 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Minolta RAVL42, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Minolta RAVL42.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Minolta RAVL42. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Minolta RAVL42 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.