USER GUIDE LCS SERIES Hardware Reference Matrix3 Audio Show Control System Edition: 2007-09-18 for CueStation 4.6.0.
Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley, CA 94702 www.meyersound.com T: +1 510 486.1166 F: +1 510 486.8356 © 2007 Meyer Sound Laboratories Inc.
© 2007 Meyer Sound. All rights reserved. Hardware Reference The contents of this manual are furnished for informational purposes only, are subject to change without notice, and should not be construed as a commitment by Meyer Sound Laboratories Inc.
.
Table of Contents LX-300 Start Up Routine 7 Overview A. Power-On Self Test B. Hardware Initialization C. System Firmware Startup EtherTracks Startup Firmware Updates 11 Before You Begin Firmware Updat.
6.
LX-300 Start Up Routine Overview 7 A. Power-On Self Test 8 B. Hardware Initialization 8 C. System Firmware Startup 9 EtherTracks Startup 10 The LX-300 contains a digital signal processor and built-in software. When you power-on ("boot") an LX-300, this software is automatically loaded.
For all other Frame IDs, the DSP performs special functions as described in Special DSP ID Codes (p. 16). These steps are described in detail in the sections that follow. A. Power-On Self Test During the first stage of power-on boot, the LX-DSP processor module waits for the LX-300 power and bus signal conditions to stabilize.
• Display "INIT" briefly on the Frame Status. • Display all front panel lights for one second. • Display "E1V6" on the Frame Status. The two digits correspond to the EPROM software version number. • Show the Frame ID in the Frame ID display.
4. Await EPROM upload. Refer to the "Matrix3 Repair Procedures" section for more information. Subsystem Initialization Failure Subsystem initialization failure will usually result in a general system failure. The system will display an error message (see LX-300 Error Codes (p.
Firmware Updates Before You Begin 11 Firmware Update Procedures 12 Special DSP ID Codes 16 The LX-DSP, LX-ELC, LX-VRA, and LX-EXP modules load operating system files into RAM during power-on. These files are stored in flash memory on each of the modules.
loading the file again. If you use the Erase Flash command for the EtherTracks module and then switch off the LX- 300 (or power fails), You will have to use VirtualLX and a serial connection to an LX-COS module to recover.
After you click OK , a blank configuration will be sent to the hardware. This is to prevent audio processing while firmware is uploaded. Another dialog box will appear, allowing you to locate the firmware file(s). All modules should be using the same firmware version as CueStation.
This assumes that the firmware in the LX-DSP and LX-ELC has been completely erased. You must have an LX- COS Communication / Synchronization module in your system since the EPROM in the LX-DSP module is only able to connect to a serial port.
4. In the drop-down menu, select Use TCP Connection . An alert box will open with a "System Reset Warning". This is a normal caution. Click Yes . 5. In CueStation 4 open the Mixer Configuration window. Select Configuration > Upload Firmware .
Special DSP ID Codes The ID switch on an LX-DSP module may be used to force the LX-300 to erase flash memory areas in the DSP, EXP, and ELC modules. You may need to do this if flash memory has become corrupted, or if there is a problem after uploading system flash.
Erasing Flash Memory Caution If you erase the LX-ELC flash, you must upload replacement firmware files to the LX-ELC module before it will work again. You will need an LX-COS module for serial connection or a network connection to an LX-ELC module on another LX-300 in the system that has not been erased.
18.
Matrix3 Repair Procedures Overview 19 Replacement of Power Fuse 19 Removal and Installation of Modules 20 Physical repair of the Matrix3 system is limited to replacement of expansion modules. Overview Skills Required • Removal of LX-300 from audio system.
Removal and Installation of Modules All modules must be installed to a valid slot position. Incorrect assignment of modules to slots may result in hardware failure or poor performance, although the modules themselves will not be damaged. Caution Circuit card assemblies contain Electrostatic Discharge Sensitive (ESDS) components.
8. Power on the LX-300, and observe the System LED and Frame Status displays. A detailed description of the boot process is provided in the LX-300 Start Up Routine (p. 7). 9. Within four seconds of power-on, the System LED must display and remain solid green (except after the first all-indicators-on test, when it will momentarily flicker red).
22.
LX-300 Maintenance Overview 23 Recommended Schedule 23 Inspection and Maintenance Procedure 23 Operational Testing 24 Dust, heat, humidity and power surges are the most significant dangers to the system and its components. For best performance, the Matrix3 should be operated in a cool, low-dust, low-humidity environment.
Important Tighten the left-hand captive machine screws on double-width modules first, to prevent warping the panel. The chassis will be secured to its rack using four captive machine screws, located at either edge of the front panel. There may be optional mounting points at the rear of the LX-300.
Hardware Specifications LX-300 Specifications 25 Power Requirements 26 Component Specifications 27 This chapter presents detailed electrical, mechanical and physical specifications for the Matrix3 and its modules. LX-300 Specifications This illustration shows a typical Matrix3 back panel.
Operating Environment 0 ° to 40 ° Celcius (32 ° to 100 ° Fahrenheit). 5% to 95% humidity, non-condensing. Low dust levels. Warning The internal temperature, as reported in the System Status window, is typically 10º C hotter than the operating en- vironment.
Table 3. LX-300 IEC AC Power Connector Name Pin Hot 1 Ground 2 Neutral 3 Component Specifications LX-ML8 Mic/Line Analog Audio Input The LX-ML8 provides eight balanced XLR audio inputs with software-controlled microphone and line level gain settings. The analog audio is converted to 24bit/48kHz digital data for processing by the LX-DSP.
Pin-outs: LX-ML8 Balanced Female XLR Use Name Pin Shield GND 1 +Analog balanced input Signal+ 2 -Analog balanced output Signal- 3 LX-Ai8 Analog Audio Input Provides eight balanced-XLR analog audio signal inputs. Performs 24bit/48kHz digital conversion with three conversion scaling settings.
ADA Scale: Inputs A to D Scale Settings CueStation INPUTS window 0dBu=.775Vrms +4dBu=1.23Vrms dBu = (20log)E1/E2 dBfs is dB full scale IEEE Standard 754 32 bit floating point format +6 dBu = 1.55 Vrms 2.2 V p-p +16 dBu = 4.9 Vrms 6.9 V p-p +26 dBu = 15.
LX-Ao8 Analog Audio Output Provides eight balanced-XLR analog audio signal outputs. Performs 24bit/48kHz digital conversion with three conversion scaling settings. Channels Eight analog outputs. Frequency Response 20Hz —20kHz. Sampling 24bit/48kHz. Dynamic Range 98dB.
ADA Scale: Outputs D to A Scale Setting CueStation OUTPUTS window +6 dBu 1.55 Vrms +16 dBu 4.9 Vrms +26 dBu 15.5 Vrms Digital Signal Level Output Scale Setting Analog Output Signal Level - 0 dBu -10 d.
LX-CBR CobraNet Audio Interface Provides CobraNet 20bit/48kHz digital audio data transmission over Ethernet networks. Pin-out CobraNet communications: Use standard CAT5 cabling. LED Status Indicator Link Watchdog Conductor Fault RX Data RX Error TX Data TX Error Green LED indicates normal operation.
LX-AES 33 Component Specifications.
34 Component Specifications.
LX-DSP System Processor Performs matrix mixing automation and control, using the TI-TMS320C6701 Digital Signal Processor. This DSP card also holds 32MB SDRAM and 8MB Flash memory, allowing stand-alone operation once programmed with an automation cue list.
LX-EXP Expansion DSP The expansion DSP card provides additional processing power for the LX-300. LX-VRA VRAS DSP The VRAS DSP provides reverberation, and early and late reflections capabilities for the Matrix3.
LX-ELC Ethernet/Wild Tracks Provides Ethernet communications link between external hardware and the Matrix3 system. Also provides a SCSI hard drive interface for use with Wild Tracks playback. Ethernet connection is IEEE 802.3 and is 100 base T. Wiring must conform to EIA.
LX-LNK Interconnect Provides a high-speed connection between LX-300s. Carries command data and 32bit/48kHz digital audio data. An optional optical transceiver module extends the maximum transmission range. Use only Link cables from Meyer Sound. These are Fibre Channel cables that have been qualified for high speed data use.
39 Component Specifications.
LX-COS Comm/Sync Provides a communications link to the CueStation host computer system (or the computer hosting your custom control software), a SMPTE Time Code signal generator and receiver, and MIDI I/O. Ports RS232 serial, RS422 serial, MIDI In/Out, XLR SMPTE In/Out Pin-outs Table 4.
Table 7. Five-pin DIN Female MIDI Out Use Name Pin 1 Shield GND 2 3 Reference current +5V 4 Send data Data 5 Table 8. XLR Female SMPTE In Use Name Pin Shield GND 1 +Balanced analog input +data 2 -Balanced analog input -data 3 Table 9.
42.
LX-300 Error Codes Status LED Blink Codes 43 Frame Status Error Codes 43 Frame Status Error Messages 44 CueStation Log Window Messages 45 The LX-300 reports the identifiable errors through one or a combination of methods: Status LED blinking, Frame Status error code reports, Frame Status error messages, and CueStation Log window messages.
Explanation Error Code Could not load Flash program IE14 Could not start BoxNet IE16 Could not start SerialNet IE17 Could not obtain TCP/IP Hostname IE18 Could not obtain Midi serial socket IE19 Could.
Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to an Analog Audio Input module; "DMA1" to a CobraNet module). CueStation Log Window Messages CueStation's Log window reports a number of errors from the Matrix3 system.
46.
Appendix Returns Policy 47 Shipping Address 47 Returns Policy Please contact one of our product specialists: Tel: +1 (626) 836-0446 Fax: +1 (626) 836-4883 http://LCSforums.com support@meyersound.com Shipping Address Product returns *must* be packaged appropriately.
48.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Meyer Sound LX-300 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Meyer Sound LX-300 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Meyer Sound LX-300 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Meyer Sound LX-300 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Meyer Sound LX-300, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Meyer Sound LX-300.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Meyer Sound LX-300. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Meyer Sound LX-300 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.