METROLOGIC INSTRUMENTS, INC. MS2xxx Stratos ® Series Configuration Addendum.
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Important Notes - Be fore You Start ...................................................................... 1 Scale Progra m Mode .
iii T ABLE OF C ONTENTS IBM Self Check out System .................................................................. 29 Various RS232 Singl e Cable Co des .................................................... 30 IBM 3 rd Generati on 46xx ..............
iv T ABLE OF C ONTENTS Continuous Mode ................................................................................. 71 EAS Deactiva tion ................................................................................. 72 Sensormatic Sc anMax Pr o .
1 I MPORTANT N OTES - B EFORE Y OU S TART It is important to carefully read the notes marked with a symbol on the pages contained in this manual. Not all conf igur ation codes are designed to be us ed for both a single and dual cable s canner/scale system.
2 S CALE P ROGRAM M ODE The following steps are only required for the scale configura tion bar codes located on pages 5 - 19 ( bar codes begi nning with 996. ) 1. Power down the scanner/scale. Then, temporarily remove the scale platter and place it in a safe location.
3 S CALE P ROGRAM M ODE Figure 3. StratosS Calibration Seal and Switch Location 5. Disconnect the scale-to-host RS232 cable from the unit ( dual cable interface only.) Figure 4. Disconnect scale-to-host RS232 Cable 6. Reinstall the platter and connect AC power to the scanner.
4 S CALE P ROGRAM M ODE 7. If the system is equipped with a remote scale display, it will read H - - -. 8. Use the vertical window to scan the desired scale configuration bar codes , located on pages 5 - 19. Figure 5. 9. Reconnect the scale-to-h ost RS232 cable to the scanner (dua l cable interface only.
5 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms ) The following bar codes can be used to confi gure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes.
6 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes.
7 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes.
8 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes.
9 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scroll Weight Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes.
10 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are o nly used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes.
11 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20.
12 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20.
13 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20.
14 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment.
15 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment.
16 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
17 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
18 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
19 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication The MS2xx0 must be in scale program mode to use this bar code.
20 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place , as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale program mode to use the following bar codes.
21 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Various Dual Cable Scanner Mode The following bar codes can be used to confi gure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
22 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes IBM 3 rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to confi gure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
23 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to confi gure a Single Cable MS2xx0.
24 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility ISS45 The following bar codes can be used to confi gure a Single Cable MS2xx0.
25 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility OPOS The following bar codes can be used to confi gure a Single Cable MS2xx0.
26 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Retailix/NCR The following bar codes can be used to confi gure a Single Cable MS2xx0.
27 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Retailix/OPOS The following bar codes can be used to confi gure a Single Cable MS2xx0.
28 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IT Retail The following bar codes can be used to confi gure a Single Cable MS2xx0.
29 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM Self Checkout System The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
30 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Various RS232 Single Cable Codes The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
31 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM 3 rd Generation 46xx The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
32 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM OEM Full Speed USB The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
33 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner 4B Handheld ³ 31643 0 Full Speed USB interface to 4B00h handheld usage.
34 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner/Scale 4A/6E Table Top ³ 31644 0 Full Speed USB interface to the 4A00h/6E00h table top scanner/scale usage.
35 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode. Enable Special Function ACK Answer ³ 14171 4 Answer simple special functions with ACK.
36 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Prefix/Suffix The following codes do not require that the MS2xx0 to be in scale program mode. Use Protocol Prefix/Suffix ³ 14171 5 Add protocol prefixes and suffixes to the bar code.
37 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3x-30 Acknowledge Responses The following codes do not require that the MS2xx0 to be in scale program mode. No 3x-30 Answer ³ 14171 0 This bar code will inhibit all ‘simple acknowledge’ (3x- 30) answers to POS or OPOS commands.
38 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func Ans 3x30 ³ 14191 4 Answer Special Function commands i n the 3x-30 format as opposed to the Ack / Nak which is the norm.
39 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func 30-30 Status ³ 14221 5 Returns Special Function commands in the 30-30 status as opposed to the 33-30 statu s.
40 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Command Reject Answer ³ 14211 7 This bar code will ignore sending a command reject answer to the POS mode.
41 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Spec Func Answer ³ 14211 6 This bar code will ignore sendin g a special function response answer in POS mode.
42 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting BCC in POS communications The following codes do not require that the MS2xx0 to be in scale program mode. Skip BCC in messages ³ 14141 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions.
43 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3 Scale Status Bytes The following codes do not require that the MS2xx0 to be in scale program mode.
44 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Scale Options The following codes do not require that the MS2xx0 to be in scale program mode. 5-Digit Weight ³ 14101 0 Sets the English Mode weight to 5-digits, as in xx.yyy pounds.
45 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Remote Display The following codes do not require that the MS2xx0 to be in scale program mode.
46 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Activate StratosSTATS ³ 99701 7 This bar code sets: • StratosSTATS bar code data formatting active.
47 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode.
48 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode.
49 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2xx0 to be in scale program mode. Beep on Weight ³ 14191 7 Request scanner beep when a successful weight is sent.
50 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes ³ 12581 0 This bar code places tighter restrictions on in-store codes.
51 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode ³ 14221 7 This bar code sets the scale to the highest priority to allow for frequent scale - POS commands.
52 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Razz on Not-On-File The following codes do not require that the MS2xx0 to be in scale program mode. Razz on Not-On-File ³ 14211 5 This bar code changes the audible to a razz signal when a Not-On-File command is received.
53 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
54 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
55 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
56 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
57 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Stratos SCHOOL ™ The following codes do not require that the MS2xx0 to be in scale program mode. Auxiliary History Report ³ 99701 1 The Auxiliary p ort may be used to download or clear data to Stratos SCHOOL ™.
58 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner The following codes do not require that the MS2xx0 to be in scale program mode.
59 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequ ence cont inued from previ ous page.
60 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. * No EAS Device ³ 33720 0 No EAS device is connected.
61 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 2 ³ 33722 0 EAS Device Type 3 ³ .
62 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 4 ³ 33724 0.
63 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. * EAS = 0 seconds ³ 84600 0 * Factory Default Setting .
64 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 2 seconds ³8 4 6 0 0 2 0 0 EAS = 3 seconds ³8 4.
65 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 4 seconds ³8 4 6 0 0 4 0 0 EAS = 5 seconds ³8 4.
66 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 7 seconds ³8 4 6 0 0 7 0 0 EAS = 10 seconds ³8 .
67 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 15 seconds ³8 4 6 0 1 5 0 0 EAS = 20 seconds ³8.
68 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. * EAS Digital Aux Port ³ 14610 0 The EAS signals use the RTS and CT S line of the Auxiliary RS232 In connector.
69 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Aux Port ³ 14611 1 This bar code allows the EAS RS232 si gnal to use the Tx Out and Rx In lines of the scanner to Aux RS232 In connector.
70 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Host Port ³ 14611 2 This bar code allows the EAS RS232 si gnal to use the Tx Out and Rx In lines of the scanner to Host RS232 In connector.
71 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Continuous Mode The following codes do not require that the MS2xx0 to be in scale program mode. EAS Continuous Mode ³ 14611 5 When in continuous mode an d the scanner is enabled, the EAS will always be online to deactivate an EAS tag.
72 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Blink Scan LED on Deactivation ³ 14611 3 The scanner will blink the sca n LED upon receipt of an EAS deactivate acknowledge signal.
73 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Fast Beep on Deactivation ³ 14611 4 Fast beep the scanner’s beeper recei pt of an EAS deactivate acknowledge sign al.
74 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Volume Switch = Manual ³ 14611 6 The volume switch is used for manual EAS deactivation. * Volume Switch = Normal ³ 14610 6 Volume switch is used for normal vol ume function.
75 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode.
76 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode.
77 S CANNER T EST B AR C ODES Supplemental Tests Display Software Numbers The following codes do not require that the MS2xx0 to be in scale program mode. These codes are for test purposes only. The following code will displa y software #’s on the 2-digit diagnostic dis play.
78.
N OTES.
N OTES.
.
.
May 2008 Printed in the USA 00 - 02034E.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic Stratos MS2xxx Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic Stratos MS2xxx Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic Stratos MS2xxx Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic Stratos MS2xxx Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic Stratos MS2xxx Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic Stratos MS2xxx Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic Stratos MS2xxx Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic Stratos MS2xxx Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.