METROLOGIC INSTRUMENTS, INC. MS9535 Voyager BT ™ Wireless Hand-Held Laser Scanner Installation and User’s Guide.
.
ii L OCATIONS C ORPORATE H EADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1- 800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673 Email: info@me trologic.
iii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..............................................................................
1 I NTRODUCTION MS9535 Voyager BT ™ laser bar code scanner is a new member of Metrologic’s Voyager series. Besides featuring the pat ented technologies of automatic trigger and CodeGate, the Voyager BT has incorporated the la test Bluetooth™ w ireless technology.
2 S CANNER AND A CCESSORIES B AS IC K IT Part # Description 9535-5 Voyager BT Scanner 9535-5M Voyager BT Scanner w ith Memory 70-79004 MS9535 VoyagerBT Wireless Hand Held Laser Scanner Installation an.
3 Q UICK S TART 1. Connect the 10-pin RJ45 male connecto r into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ when the connection is made. 2. Connect the plug of the power supply into the pow er jack on the bottom of the cradle.
4 Q UICK S TART (C ONTINUED ) 5. Scan a bar code anyw here within 10 me ters from the cradle. The scanner will beep once and flash the w hite LED. T he blue LED of the cradle will also flash once, indicating that the bar code has been successfully read and transmitted.
5 RS232 AND L IGHT P EN S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connecto r into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ w hen the connection is made. 3. Connect the plug of the power supply into the pow er jack on the bottom of the cradle.
6 K EY B OARD W EDGE S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connecto r into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ when the connection is made. 3. Connect the plug of the power supply into the pow er jack on the bottom of the cradle.
7 USB K EYBOARD S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the USB B type connector into the center jack on the bottom of the charger cradle. 3. Connect the plug of the power supply into the pow er jack on the bottom of the charger cradle.
8 IBM S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connecto r into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ w hen the connection is made. 3. Connect the plug of the power supply into the pow er jack on the bottom of the charger cradle.
9 F ULL S PEED USB WITH E XTERNAL P OWER S UPPLY S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the charger cradle. You w ill hear a ‘click’ when the connection is made.
10 F ULL S PEED USB WITH P OWER F ROM R EGISTER S CANNER I NSTALLATION 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connecto r into the 10-pin modular jack on the bottom of the charger cradle. You w ill hear a ‘click’ when the connection is made.
11 E STABLISH C OMMUNICATION B ETWEEN S CANNER AND C RADLE Before the normal scanning starts, Bluetooth communication between the scanner and cradle must be established. The communication between the scanner and cradle can be established by scanning the Bluetooth address code located on the cradle.
12 C HARGING THE S CANNER Prior to performing any operation w ith the scanner, make sure it has been charged. The following explains how to determi ne if the scanner needs recharging: 1. During operation, the scanner give s tw o beeps after a successful scan.
13 C HARGING THE S CANNER (C ONTINUED ) Safety Precautions for Lithium Batteries: • Do not place batteries in fire or heat the batteries • Do not store batteries near fire or other high temperatur.
14 R ECEIVER / C HARGER C RADLE The cradle of MS9535 works both as a receiver and a charger. As a receiver, after establishing Bluet ooth communication with the scanner, the cradle receives date being scanned by the scanner and transmits it to the host.
15 C RADLE P ARTS The main parts of the cradle includes: a) Blue LED The blue LED indicates the “connecting” st atus of the cradle with the scanner. When the Bluetooth connection breaks, the blue LED will flash. A single flash of the blue LED indicates data has been received from the scanner.
16 S CANNER P ARTS MS9535 To p View MS9535 Side View A mber LED CodeGate Button Out p ut Windo w Plastic Feet / Charge Contacts Blue LED MS9535 Top View White LED.
17 A UDIBLE I NDICATORS When the scanner is in operation, it provides audi ble feedback. These sounds indicate the status of the scanner . Eight settings are avail able for the tone of the beeper (normal, 6 alternate tones and no t one).
18 V ISUAL I NDICATORS The MS9535 has three LED indicators (b lue, white and amber) located on the head of the scanner. When the scanner is in operation, the flas hing or stationary activity of the LEDs indicates the st atus of the current scan and the scanner.
19 V ISUAL I NDICATORS ( CONTINUED ) A lternating Flashing of Blue a nd White This indicates the scanner is in program mode. Two razzberry tones indicate that an invalid bar code has been scanned while in this mode . If the scanner is in RangeGate active mode, this indicates the SRAM of the scanner becomes full.
20 F AILURE M ODES Flashing Blue and one Razzberry Tone This indicates the scanner has experienced a laser sub- system failure. Return the unit for repair to an authorized service center. Flashing Blue and White with Tw o Razzberry Tones This indicates the scanner has experienced a scanning mechanism failure.
21 P ROGRAMMING M ODES The MS9535 Voyager BT has 2 modes of programming. Bar Codes Voyager BT can be configured by scanning the bar codes in the MetroSelect Single-Line Programming Guide ( MLPN 00-02544B) and Bluetooth Programming Addendum (00-02024A).
22 U PGRADING THE F LASH ROM F IRMWARE The MetroSet 2 program also allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of softw are. It requires the use of a personal computer running under Windows 95 or gr eater and the use of a communication port.
23 L ABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code.
24 D EPTH OF F IELD Minimum Bar Code Element Width A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 -.
25 IR A CTIVATION.
26 C ONNECTING TO O THER B LUETOOTH D EVICES Other than the cradl e, the MS9535 Voyager BT scanner can also link to other Bluetooth compatible devices, such as a computer, printer or laptop. A Bluetooth communication between the scanner and the other device must be established before the system w orks.
27 C ONNECTING WITH O THER B LUETOOTH D EVICE (C ONTINUED ) When MS9535 acts as Server: To enable the MS9535 to act as a server and to be discovered by another Bluetooth device, scan the below Provide Service code. This w ill allow other Bluetooth devices to send inquiries to the scanner and attempt communication.
28 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms.
29 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution Unit scans, Communicates and beeps twice Same symbol timeout set too short Adjust same symbol timeout for a longer time. The unit powers up, but does not scan/or beep Beeper disabled.
30 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution Scanner beeps at some bar codes and NOT for others of the same bar code symbology The aspect ratio of the bar code is out of tolerance Check print mode. The type of printer could be the problem.
31 T ROUBLESHOOTING G UIDE ( CONTINUED ) Symptoms Possible Causes Solution The unit is transmitting each character twice Configuration is not correct Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
32 D ESIGN S PECIFICATIONS O PE RAT I ON AL Light Source: Visible Laser Diode 650 nm ± 10 nm Laser Power: 0.96 mW (peak) Depth of Scan Field: 0 mm – 203 mm (0” – 8”) for 0.330 mm (13 mil) bar code at default setting Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.
33 D EFAULT S ETTINGS Many functions of the scanner and cradl e can be “programmed” – that is, enabled or disabled. The scanner and cr adle are shipped from the factory programmed to a set of default conditions. The default parameter has an asterisk (*) in the charts on the following pages.
34 D EFAULT S ETTINGS ( CONTINUED ) PARA ME TER D E F A U L T RS-232 LIGHT PEN IBM 46XX KBW USB Mod 43 Check on Code 39 MSI-Plessey 10/10 Check Digit MSI-Plesse.
35 D EFAULT S ETTINGS ( CONTINUED ) PARA ME TER D E F A U L T RS-232 LIGHT PEN IBM 46XX KBW USB Same symbol rescan timeout 750 msecs Same symbol rescan timeout 875 msecs * .
36 D EFAULT S ETTINGS ( CONTINUED ) PARA ME TER D E F A U L T RS-232 LIGHT PEN IBM 46XX KBW USB Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix .
37 D EFAULT S ETTINGS ( CONTINUED ) PARA ME TER D E F A U L T RS-232 LIGHT PEN IBM 46XX KBW USB 100 msec to Find Supplement Programmable in 100 msec steps (max 800 msec) * Coupon C.
38 1 10 C RADLE AND C ABLE T ERMINATIONS Cradle Pinout Connections The MS9535 cradle has 3 ports on the botto m. One is for power, and the other two are for interfaces connection.The 10-pin RJ45 modular jack has diffent configurations for different interfaces.
39 C RADLE AND C ABLE T ERMINATIONS ( CONTINUED ) MI9535-511 IBM Pin Function 1 Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM B- Transmit 8 IBM A+ R.
40 C RADLE AND C ABLE T ERMINATIONS (C ONTINUED ) USB Port Pin Function 1 VCC 2 D- 3 D+ 4 Ground Cable Connector Configurations (Host End) USB Cable [ MLPN 52-52828A] Pin Function 1 VCC 2 D- 3 D+ 4 Gr.
41 C RADLE AND C ABLE T ERMINATIONS (C ONTINUED ) IBM Cable [ MLPN 54-54250A-N] Pin Function 1 Ground 2 IBM A+ 3 IBM B- 4 Reserved Full Speed USB Cable with pow er from Register [ MLPN 54-54073A] Pin .
42 C RADLE AND C ABLE T ERMINATIONS ( CONTINUED ) Cable Connector Configuration The Keyboard Wedge cable [ MLPN 57-57002A] is terminated with a 5-pin DIN female connector on one end, and a 6-pi n mini DIN male on the other.
43 L IMITED W ARRANTY The MS9535 scanners are manufactured by Metrol ogic at its Suzhou, China facility. The MS9535 scanners have a two (2) year limited w arranty from the date of manufacture.
44 N OTICES Notice The FCC requires that you be advised of certain requirements inv olving the use of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
45 N OTICES (C ONTINUED ) Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten.
46 N OTICES (C ONTINUED ) Notice The FCC requires that you be advised of certain requirements inv olving the use of this device. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
47 N OTICES (C ONTINUED ) Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten.
48 P ATENTS Patent Coverage The Voyager BT METROLOGIC product may be covered by one or more of the following US Patents: US Patent No. 4,958,984; 5,081, 342; 5,260,553; 5, 340,971; 5,340,973; 5,424,52.
49 I NDEX A AC Input/Outlet ........ 5, 6, 7, 8, 9, 10 accessori es ................................... 2 Accessori es ................................... 2 adapter .......................................... 2 Approval s ..............................
50 P parts .............................................. 2 PC ............. 5, 22, 30, 32, 38, 40, 42 Pin Assign ments .......................... 42 Port ................................................ 6 Power Supply ................................
.
July 2005 Printed in China 70 - 7 9004 E.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic MS9535 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic MS9535 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic MS9535 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic MS9535 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic MS9535, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic MS9535.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic MS9535. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic MS9535 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.