Manuale d’uso / di manutenzione del prodotto MS2422 del fabbricante Metrologic
Vai alla pagina of 66
METROLOGIC INSTRUMENTS, INC. MS2421 / MS2422 Bar Code Scanner Installation and User’s Guide.
Copyright © 2009 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief pas sages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS I NTRODUCTION Manual Scope ................................................................................................................... ....................................................... 1 Product Ov erview .........
iii T ABLE OF C ONTENTS S CANNER O PERATION Scan Z one .............................................................................................................................................................................. 25 Wake Activation Area (P hotocell LED Output) .
1 I NTRODUCTION M ANUAL S COPE This guide provides informati on on the installation, setup and oper ation of the MS2421 and the MS2422 scann er only models .
2 I NTRODUCTION B ASE K IT C OMPONENTS B AS E K IT C OMPONENT S Part # Description M S 242 x -105N z Bar Code Scanner 1 Scanner Only, Scale Ready – Compact x 2 Scanner Only – Sub-Compact D Diamone.
3 I NTRODUCTION O PTIONAL A CCESSORIES O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer - Regulated Output: +5.2V @ 2.5A +12V @ 0.8A 46-00980-R 120V United States and Cana da 46-00.
4 I NTRODUCTION G ENERAL P RECAUTIONS The following are some gener al precautions to remember when handlin g the MS2421/MS2422 scanner . D O N OT T URN the unit upside do wn with the platter in place. D O N OT P RESS on the window in the platter or the vertical window frame.
5 I NTRODUCTION MS2421 / MS2422 S CANNER D ESIGN S PECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 m m (13 mil) Bar Code Vertical Depth of Field: 0 mm - 216 mm (0”- 8.
6 B ASE M ODEL C HARACTERISTICS MS2421 Scanner Components Figure 5. MS2421 Components Components I TEM N O . D ESCRIPTION OF I TEM 1 Volume/Tone Multi-Function Button (see page 35) 2 Blue LED Indicato.
7 B ASE M ODEL C HARACTERISTICS MS2421 Scanner Dimensions Figure 6. MS2421 Dimensions Connector Panel Figure 7. MS2421 Connector Panel * Scale ready MS2421 mode ls supply additional connectors for scale a nd display communication cabli ng. The use of these connections is depe nde nt on the specific manufacturer of the scale bein g integrated.
8 B ASE M ODEL C HARACTERISTICS MS2421 Scanner Caution and Serial Number Labels Figure 8. MS2421 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (S afety E xtra L ow V oltage) according to EN/IEC 60950-1.
9 B ASE M ODEL C HARACTERISTICS MS2422 Scanner Components Figure 9. MS2422 Components Components I TEM N O . D ESCRIPTION OF I TEM IN F IGURE 15 1 Volume/Tone Multi-Function Button (see page 35) 2 Blu.
10 B ASE M ODEL C HARACTERISTICS MS2422 Scanner Dimensions Figure 10. MS2422 Dimensions Connector Panel Figure 11. MS2422 Connectors Specifications are subjec t to change without notice.
11 B ASE M ODEL C HARACTERISTICS MS2422 Scanner Caution and Serial Number Labels Figure 12. MS2422 Label Locations (Top) and Exa mples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (S afety E xtra L ow V oltage) according to EN/IEC 60950-1.
12 I NSTALLATION Q UICK I NSTALLATION O UT LINE The following is a quick previ ew of the steps required for 1 st time installations. Each item is discussed in detail later in this section. • Determine clearance, ventilation and service access requirements.
13 I NSTALLATION U NPACKING THE U NIT 1. Make sure the shipping box is top-side u p before opening. 2. Remove the accessories box and check the box’s content for the follo wing items. • Product Manuals • Power Supply • Communication Cables 3. Lift the scanner out of the shipping box by g ripping the bottom of the unit on both sides.
14 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2421 Mounting Diagram Figure 17. MS2421 Mounting Diagra m Specifications are subjec t to change without notice.
15 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER MS2422 Mounting Diagram Figure 18. MS2422 Mounting Diagra m Specifications are subjec t to change without notice.
16 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) RS232 The following steps describe ho w to properly insta ll the cables for an RS232 application. The scanner mu st then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the scanner will communicate properly with the host system.
17 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) RS232 xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual.
18 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) F ULL S PEED USB The following steps describe ho w to properly install the cables for a Full Speed USB scanner applicati on. The scanner must then be configured to match the host’s USB paramet ers.
19 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) F ULL S PEED USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation M ode only.
20 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) IBM 46 XX The following steps describe ho w to properly install the cables for an IBM 46xx scanner application. T he scanner must then be configured to match the host’s IBM 46xx parameters.
21 I NSTALLATION C ABLE I NSTALLATION (I NT ERF ACE S PECIFIC ) IBM 46 XX xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual.
22 I NSTALLATION C ABLE I NSTALLATION (S ECONDARY M ETROLOGIC S CANNER ) The following steps describe ho w to properly install the cables between a secondar y Metrologic scanner and the MS2421/MS2422 scanner. The MS2421/ MS2422 and the secondar y scanner must then be configure d to communicate properly.
23 I NSTALLATION C ABLE I NSTALLATION (S ECONDARY M ETROLOGIC S CANNER ) † See Aux power notes on page 22 See power source caution statement on pages 8 or 11 of this manual.
24 I NSTALLATION EAS D EACTIVATION SW1 and SW2 are the s witch banks inside t he Checkpoint device that set the deactivation range. The follo wing is a list of Checkpoint recommended s witch bank settings.
25 S CANNER O PERATION S CAN Z ONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subjec t to change without notice.
26 S CANNER O PERATION S CAN Z ONE Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subjec t to change without notice.
27 S CANNER O PERATION W AKE A CTIVATION A REA (P HOTOCELL LED O UTPUT ) The MS2421/MS2422 scanner’s default po wer save mode † is Dual Action Power Save Mode #2 (see page 34) . This po wer save mode † turns the laser OFF after a configured period of non-use t hen turns the motor OFF after thirt y-minute intervals.
28 S CANNER O PERATION W AKE A CTIVATION A REA S ENSITIVITY (P HOTOCELL LED O UT PUT R ANGE ) Changing the Wake Area Sensitivity Level (Photocell LED Range Adjust) The MS2400 Series bar code scanner wake area sensitivity level can be set to the end users prefere nce by scanning one of the Photocell Sensitivit y ad justment bar codes belo w.
29 Figure 30. Blue LED S CANNER O PERATION I NDICATOR D ESCRIPTIONS Audible When in operation, the MS242 1/MS2422 scanner provides audibl e feed back that indicates the status of the unit and the current scan. Eight settings are available for the tone of the beep (normal , 6 alter nate tones and no tone) plus three volume settings.
30 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Visual Steady Blue When all lasers are active, the blue LED is illumin ated. The bl ue LED will remain illuminated until all l asers are deactivated . Steady Blue and Single blue Flash When the scanner successfully reads a bar code, the bl ue LED will flash and the scanner will beep once.
31 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicat or Display There is a two-digit error code displa y located under horizonta l output windo w near the Metrologic logo on the platter (see figure below).
32 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicat or Display E RROR C ODE D ESCRIPTION 11 SWITCH ERROR – The switch used for vol ume selection or sleep mode is detected in error (al ways closed). The condition is self-correcting if possible.
33 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicat or Display E RROR C ODE D ESCRIPTION 29 LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNING – The laser in the left vertical scanning subsystem is drawing too little current. The laser is pro bab ly not on.
34 S CANNER O PERATION P OWER S AVE M ODES The MS2421/MS2422 bar code scanners h ave five conf igurable power save modes. Refer to the MetroSelect Configuratio n Guide for additional information on Po wer Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF & ON after a configured period of non- use.
35 S CANNER O PERATION B EEPER O PTIONS AND B UTTON F UNCTIONS Changing the Beeper To ne Beeper tones may be configured incrementa l ly using the following bar code. The ne w tone will be heard followed by a short pause. Two more new tones will be he ard signifying the new setti ng has been stored in memory.
36 S CANNER O PERATION S TAR TUP When the scanner first receives po wer, the blue LED will turn on and the scanner will beep onc e. The scanner is no w ready to scan. P OWER -U P T EST M ODE When a MS2421/MS2422 scanner is first po wered up, it cycl es through a number of self-tests before starting normal operation.
37 M AINTENANCE H ORIZONTAL S CAN W INDOW R EPLACEMENT After the replacement platter has been install ed, remove all protective film from the new platter’s windo w. The unit will not func tion properly if the p rotective film is not remov ed. Figure 36.
38 M AINTENANCE D AILY M AINTENANCE Smudges and dirt can interfere with the pr o per scanning of a bar code. Therefore, the horizontal and vertical output windows will need occasiona l cleaning. For the vertical and horizontal (platter) glass windows: 1.
39 T ROUBLESHOOTING The following guide is for reference purpos es only. Contact a Metrologic representative at 1-800-ID-MET RO or 1-800-436- 3876 to preserve the limited warranty terms . Symptom Possible Cause(s) Solution All Interfaces No LED, beep or motor spin.
40 T ROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The print quality of the bar code is suspect. Check the character length lock. Scanner beeps at some bar codes and NOT form others of the same bar code symbology. The aspect ratio of the bar code is out of tolerance.
41 T ROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and host may not be configured for the same interface. Check that the scanner and the host are configured for the same interface.
42 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS Many functions of the scanner can be "config ured" - that is, enabl ed or disabled. The scanner is shipped from the factor y pre- configured to a set of default conditions. The default param eter of the scanner has an asterisk ( * ) in the charts on the following pages.
43 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 IBM 46 XX USB RSS Expanded Enable 9 9 9 Expanded ID “]e0” * 9 9 9 RSS Limited Enable 9 9 9 RSS Limited ID “]e0” * 9 9.
44 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 IBM 46 XX USB Dual Action Power Save Mode #2 * 9 9 9 Same Symbol Rescan Timeout: 500 msecs Configurable in 50 msec steps (MAX 6.
45 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 IBM 46 XX USB EAN 128 Enable 9 9 9 Enable French Pharma 9 9 9 Enable Matrix 2 of 5 Check Digit 9 9 9 Enable Hong Kong 2 of 5 .
46 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 IBM 46 XX USB STX Prefix 9 9 TAB Prefix 9 9 Metrologic Prefix 9 9 UPC Prefix 9 9 ETX Suffix 9 9 TAB Suffix 9 9 Carriage Retur.
47 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 IBM 46 XX USB Five Digit Redundancy 9 9 9 Enable Coupon Code 128 9 9 9 Transmit Coupon ‘]C1’ * 9 9 9 Group Separator * 9 .
48 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS Default settings for “ Aux ” interface The secondary scanner and the MS24 21/MS2422 scanner al ways co mmunicates via RS232.
49 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS The MS2421/MS2422 scanner terminates t o 10-pin modular jacks located on the bottom of the unit. The serial num ber label indicates the model number a nd interface of the scanner. EAS DC Power Pin Function Pin Function 1 EAS In 1 No Connect 2 EAS Out 2 Earth Ground 3 No Connect 4 5.
50 S CANNER AND C ABLE T ERMINATION S S CALE R EADY MS2421 M ODELS – A DDITIONAL P INOUT C ONNECTIONS There are four additional 10- pin modular jacks located on the bottom of the of the MS2421 scanner mo dels that may be used for an integrated scale applica tion and the use of a remote display.
51 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS The following cables are examples of some of the standar d cables that may be shipped with the MS2421/MS2422 bar code scanner.
52 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Aux Port Configuration Cable * , MLPN 57-57008 x -N-3 Pin Function ** 1 No Con nect 2 Output from Scanner 3 Input to Scanner 4 No.
53 R EGULATORY C OMPLIAN CE S AFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, E N: 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performa nce of procedures other than t hose specif ied herein may result in haz ardous laser light exposure.
54 R EGULATORY C OMPLIAN CE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following is applicable w hen the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’ap pliquent aux cables de sca nner dépa ssant 3 métres (9.
55 R EGULATORY C OMPLIAN CE EMC Class B Devices The following is applicable w hen the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’ap pliquent aux cables de scanner n e dépassant pas 3 métres (9.
56 L IMITED W ARRANTY The MS2400 Series bar code scanners are manufactured by Metrologic at its Black wood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MS240 0 Series bar code scan ners have a two (2) year limited warranty from the date of manufacture.
57 P ATENTS Patent Information This METROLOGIC product may be covered by, but not limi ted to, one or more of t he following U.S. Patents: U.S. Patent No.
58 I NDEX A AC ...................................................................... see power application ................................................................. 31, 41 audible........................................................... see indicators AUX .
59 I NDEX S safety......................................................................... 54, 55 Scale ............................................................................... 50 scan patte rn .................................................
.
.
January 2009, Version 04 00 - 05311 A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic MS2422 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic MS2422 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic MS2422 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic MS2422 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic MS2422, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic MS2422.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic MS2422. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic MS2422 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.