METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User’s Guide.
Copyright © 2007 by Metrologic Instruments, Inc. All right s reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Introduction................................................................................................ 1 Opening the MX001 Industri al Cont ro l Box ............................................... 2 Internal Co mponents ..
iii T ABLE OF C ONTENTS Sensors Powered Indepen dent ly that Provide Either 12V, or a 10mA DC Output Signal with a Sens or Alarm ..................... 22 Sensors that Provide Switch Closures or Relay Type Output with a S ensor Alarm...................
1 I NTRODUCTION Metrologic’s MX001 Industrial Control Interfa ce enhances Metrologic’s line of industrial laser scanners. It does this by providing a way to connect an external object sensor to the scanner and a way for the scanner to control an external device through an electronic switc h (a TRIAC).
2 O PENING THE MX001 I NDUSTRIAL C ONTROL B OX To open the MX001 box for wiring and configuration, proceed as follo ws: 1. Loosen the lid clamp scre w with a flat blade screwdriver. 2. Disengage the clamp by pushing t he lid down, then move the clamp to the left, and rotate it outward in a counterclock wise direction.
3 I NTERNAL C OMPONENTS The following illustration an d list explain the parts that pertain to the instal lation and operation of the MX001. 1. Power Transformer Supplies a stepped down and isolated voltage that produces the 12V DC power for the industrial control box and external sensor.
4 LED S TATUS I NDICATORS The LED, (light emitting diode) status i ndicat ors are found just below the voltage selector switch. They indicate the oper ating state of the 12V power supply, the TRIAC and the status of the sensor and sensor alarm i nputs.
5 C ONFIGURING THE MX001 FOR 115 OR 230 V OLT O PERATION Before applying po wer to the MX001, it must first be configured for either 115 or 230 volt operation as requ ired. Th is is accomplished by using the voltage selector switch and the installatio n of the proper fuses.
6 C ONFIGURING THE MX001 FOR 115 OR 230 V OLT O PERATION USA: 115V Operation (continued) 6. Press the end of the 1/8 Amp fuse into the other gray fuse hold er cap unitl it seats. 7. Insert the fuse and cap into the F2 control fuse holde r with the screwdriver slot pointing toward the power transformer.
7 C ONFIGURING THE MX001 FOR 115 OR 230 V OLT O PERATION Europe/Asia: 230V Operation 1. Move the voltage selector to the le ft with a small screwdriver so that the 230V legend sho ws in the window. 2. Open the fuse kit and remove the follo wing: • (2) Black Fuse Holder Caps • (1) 6.
8 C ONFIGURING THE MX001 FOR 115 OR 230 V OLT O PERATION Europe/Asia: 115V Operation 1. Move the voltage selector to the righ t with a small screwdriver so that the 115V legend sho ws in the window. 2. Open the fuse kit and remove the follo wing: • (2) Black Fuse Holder Caps • (1) 6.
9 L OCATING THE T HREE S TRAIN R ELIEFS AND THE S IGNAL C ONNECTOR There are three strain reliefs and one 8- pin signal connector locate d on the bottom of the MX001 box. The two large strain reliefs on th e left side allow the use of flexible cordage for MX001 p ower input and controlled po wer (TRIAC) output in that order.
10 C ONNECTING THE AC P OWER I NPUT C ABLE 1. Make sure power is not being applie d to the power cable that is to be connected to the unit. 2. Open the terminals in the pow er term inal block by turning each screw counterclockwise until ther e is enough space to insert wires.
11 C ONNECTING THE TRIAC C ONTROLLED P OWER O UTPUT C ABLE The MX001 box contains a po wer line TRIAC that acts as an electronic po wer output switch operated by the scann er and capable of controlling a current load of 6 amps in the USA. In Europe, t he maximum current load supported is 5 Amps.
12 T EMPORARILY D ISABLING THE TRIAC O UTPUT If, during set up or maintenance, there is a need to disable the TRIAC output of the MX001, simply remove the F1 TRIAC fuse.
13 S ENSOR S UPPORT There are many different types of sensor s availa ble, which will work with the MX001 control box. Common types: 1. Sensors powered independe ntly which provide 12V, 5V, or a 10mA DC output signal (sourcing type output). 2. Sensors that provide switch closures or relay type o utputs.
14 S ENSOR S UPPORT Connecting the Sensor Reference the documentation that came with your sensor to determine the function of each sensor wire. Then, refer to one of the procedur es on the following p.
15 S ENSOR S UPPORT Sensors Powered Independently that Provide Either 12V, 5V or a 10mA DC Output Signal 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the senso r terminal block by turning eac h screw counterclockwise until ther e is enough space to insert wires.
16 S ENSOR S UPPORT Sensors Powered Independently that Provide Either 12V, 5V or a 10mA DC Output Signal Caution: When configured for a 1 0mA DC source input , the MX001 box expects a curre nt limited 10 mA DC signal to be supplied by the sensor. Failure to limit thi s current to 10mA can damage the sens or input circ uitry of the sy stem.
17 S ENSOR S UPPORT Sensors that Provide S witch Closures or Relay Type Output 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the sensor terminal bl ock by turning each screw counterclockwise until ther e is enough space to insert wires.
18 S IN - S IN+ +12V OUT Figure 10 A IN+ A IN- COMMON 1 2 3 4 5 6 J1 1 S SET UP 6 Figure 11 S ENSOR S UPPORT Low Voltage Self-Contained DC Sen sors with a Current Sinking Output 1.
19 S IN - S IN+ +12V OUT Figure 12 A IN+ A IN- COMMON 1 2 3 4 5 6 J1 1 S SET UP 6 Figure 13 S ENSOR S UPPORT Low Voltage Self-Contai ned DC sensors with a Current Sourcing Output 1.
20 S ENSOR S UPPORT “Universal” Self-Contained Se nsors that Prov ide a Single Pole/Double Throw (SPDT) Relay Output 1. Make sure the “universal” sensor can operat e on +12 volts DC at 200mA or less. If so, then the MX001 box can supply the + 12 volts necessary to power the “universal” sensor.
21 S ENSOR S UPPORT “Universal” Self-Contained Se nsors that Prov ide a Single Pole/Double Throw (SPDT) Relay Output 13. Position the jumper on pins 5 and 6 of the J1 (S SET UP) header .
22 S ENSOR S UPPORT Sensors Powered Independently that Provide Either 12V, 5V or a 10mA DC Output Signal with a Sensor Alarm 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the senso r terminal block by turning eac h screw counterclockwise until ther e is enough space to insert wires.
23 S ENSOR S UPPORT Sensors Powered Independently that Provide Either 12V, 5V or a 10mA DC Output Signal with a Sensor Alarm • For 12V DC output signals, position the j umpers on pins 1 and 2 of the J1 (S SET UP) and J2 (A SET UP) headers .
24 S ENSOR S UPPORT Sensors that Provide S witch Closures or Relay Type Output with a Sensor Alarm 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the sensor terminal block b y turning each screw counterclockwise until ther e is enough space to insert wires.
25 S ENSOR S UPPORT Low Voltage Self-Contai ned DC Sensors with Current Sinking Output s and Senso r Alarm 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the sensor terminal bl ock by turning each screw counterclockwise until ther e is enough space to insert wires.
26 S ENSOR S UPPORT Low Voltage Self-Contai ned DC Sensors with Current Sourcing Output and Sensor alarm 1. Make sure power is not being applie d to the unit. 2. Open the terminals in the senso r terminal block by turning eac h screw counterclockwise until ther e is enough space to insert wires.
27 S ENSOR S UPPORT “Universal” Self-contained Sensor s That Provide Single Pole/Double Throw (SPDT) Relay Outputs for Both Object Sensing and Sensor Alarm 1. Make sure the “universal” sensor can operat e on +12 volts DC at 200ma o r less. If so, then the MX001 box can supply the + 12 volts necessary to power the “universal” sensor.
28 S ENSOR S UPPORT “Universal” Self-contained Sensor s That Provide Single Pole/Double Throw (SPDT) Relay Outputs for Both Object Sensing and Sensor Alarm 12. Determine from the literature supplied with your sensor which sensor alarm relay output makes contact with its common terminal when sensing conditions become margina l.
29 C LOSING THE MX001 I NDUSTRIAL C ONTROL B OX 1. Close the lid of the MX001 bo x. 2. Rotate the clamp clock wise while pushing do wn on the lid. Then move the clamp to the right, positioning it over the ledge on th e lid. 3. Fasten the clamp in place by tighten ing its screw with a flat blade screwdriver.
30 C ABLE P IN O UTS FOR THE 8-P IN AND 19-P IN C ONNECTORS The standard scanner link ca ble length is 3 feet – 1 meter. Other scanner link cable lengths are available u pon request. Contact Metrologic Customer Service for additional details. If there is a need to lengthen the scanner link cable, use a cable with #26 wire.
31 S PECIFICATIONS MX001 Specifications Application: Industria l Contr ol Interface Orientation: L-bracket with TECH scanner or independentl y mounted Dimensions: 152mm L x 102mm W x 76m m D (6” x 4” x 3”) Weight: 1.
32 T ROUBLESHOOTING No Operation – Green LED off: 1. Check power input wiring for correct connec tion and security at power terminal block. (Wires must be stripped befor e insertion into the terminal block and terminal block screws must be tight, clamping the stripped wire firmly in the block.
33 T ROUBLESHOOTING No TRIAC Outpu t with Red TRIAC LED On: 1. Check that the TRIAC load is properl y connected to the TRIAC terminal block . (Wires must b e stripped before insertion int o the terminal block and terminal block screws must be tight, clamping the stripped wire firmly in the block.
34 T ROUBLESHOOTING TRIAC Output Activ e with Red TRIAC LED off: Tests for AC power output from the TRIAC should o nly be made when a device or load is connected bet ween the TRIAC OUT and NEUTRA L terminals of the TRIAC terminal block .
35 T ROUBLESHOOTING Reversed Sensor Input Indication (Red S in LED goes off when object is sensed): 1. Some sensors provide the option of output a ctivation when they sense or do not sense an object. Having the sensor set up to produce an output when it does not sense an object will result in reversed sens ing conditions.
36 T ROUBLESHOOTING Continuous Sensor Input Indication (Red S IN LED continuously on): 1. Review the documentation that came with your sensor to learn the type of output the sensor provides . Review the MX001 manual and find the set up procedure that applies to your sensor.
37 T ROUBLESHOOTING Erratic Sensor Alarm Indicat ion (Red A IN LED blinks): 1. Check the positioning of the sensor to make sure it is orie nted correctly. 2. Check to see if the sensor is dirty and clean it if necessary. 3. Check sensor gain/sensitivity adjustm ent for correctness.
38 T ROUBLESHOOTING Operational Check Out Procedu re for the MX001 Box: The following procedure prov ides a basic test of the MX001 hardware and confirms effective communication with the HoloSet program. This quick test should be preformed before the M X001 box has been confi gured by the HoloSet program for its final applicatio n.
39 T ROUBLESHOOTING 10. Short the A IN - terminal screw to the COMMON terminal screw with a short piece of wire. The red A IN LED should light and the scanner should emit a repetitive warning t one as long as this connection is maintained. 11. Disconnect then reconnect power to the scanner.
40 L IMITED W ARRANTY The MX001 interface is manufactured by Metrologic at its Blackwood, New Jersey, USA facility. The MX001 interface has a two (2 ) year limited w arranty from the date of manufacture.
41 N OTICES Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class A Devices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rule s.
42.
.
March 2004, Version 01 Printed in the USA 00 - 02173.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic Instruments MX001 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic Instruments MX001 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic Instruments MX001 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic Instruments MX001 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic Instruments MX001, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic Instruments MX001.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic Instruments MX001. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic Instruments MX001 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.