Manuale d’uso / di manutenzione del prodotto MS7100 del fabbricante Metrologic Instruments
Vai alla pagina of 45
METROLOGIC INSTRUMENTS, INC. MS7100 Series Fixed Projection Laser Scanner Installation and User’s Guide MLPN 2408 Printed in USA October 1998.
ii Locations : USA Corporate Headquarters Europe Metrologic Instruments, Inc. Metrologic Instruments GmbH 90 Coles Road Dornierstrasse 2 Blackwood, NJ 08012 82178 Puchheim b. Customer Service: 1-800-ID-METRO Munich, Germany Tel: 609-228-8100 Tel: 49-89-89018-0 Fax: 609-228-6673 Fax: 49-89-89019-200 info@metrologic.
iii Table of Contents Introduction ................................................... 1 Scanner and Accessories ......................................... 2 Quick Start .................................................... 3 Operational Test ..........
iv Appendix A Design Specifications 27, 28 Appendix B Default Settings 29-32 Appendix C Pin Assignments 33-35 Appendix D Warranty and Disclaimer 36, 37 Appendix E Notices 38, 39 Index 40, 41.
1 Introduction Orbit™ is an aggressive, omnidirectional laser bar code scanner. Light-weight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores.
2 Scanner and Accessories The following is a list of the parts included in the MS7100 kit. ! MS7100 Hand-Held Laser Scanner - Refer to page 26 for available communication protocols ! Power Transformer AC in 120V, 220V- 240V Continental European or 220V- 240V UK.
3 Quick Start 1.) Plug in the scanner. When the MS7100 is ready to scan, the red LED will turn on, then the green LED will flash and the scanner will beep once. (the green LED will remain on for the duration of the beep). 2.) The scanner is shipped from the factory programmed with default settings.
4 Operational Test Metrologic recommends using the external power supply provided with the scanner when operating the MS7100. When using power supplied by the host, the host system should supply a minimum of 250 mA of current @ 5VDC. Keyboard Wedge Scanners: 1.
5 Scanner Installation: Powered by External Power Supply To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( S afety E xtra L ow V oltage) according to EN 60950. 1. Turn off the host system.
6 Scanner Installation: Powered by Host Device The MS7100 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin modular plug of the PowerLink cable into the jack then connect the other end of the PowerLink cable to the host. Refer to Appendix C page 33 for pin assignments.
7 Scanner Installation to the PC for the Scanner with Built-in PC Keyboard Wedge Interface To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( S afety E xtra L ow V oltage) according to EN 60950.
8 Green and Red LEDs: When the red LED is on, this indicates that the laser is on. When the green LED flashes on, the scanner has read a bar code successfully. When the green light turns off, communication to the host is complete. The LEDs are also used as diagnostic indicators and mode indicators.
9 Audible Indicators When the MS7100 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect Programming Guide MLPN 2407.
10 Failure Modes Flashing Red and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center. Flashing Red and Green and Two Razzberry Tones This indicates the scanner has experienced a motor failure.
11 Visual Indicators There are a red LED and a green LED on the head of the Orbit MS7100. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.
12 Labels Each scanner has labels on the bottom of the unit. One label contains information such as the model number, date of manufacture, serial number and notes that the device is a Class IIa laser product. The other label states the device is an LASERKLASSE 1 product.
13 Depth of Field Specifications (based on 100% UPC bar codes) Optimal Depth of Field (default) Close Depth of Field.
14 Normal Depth of Field Far Depth of Field.
15 Depth of Field by Minimum Bar Code Element Width Optimal Depth of Field (default).
16 Close Depth of Field.
17 Normal Depth of Field.
18 Far Depth of Field.
19 Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth.
20 Troubleshooting Guide The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 36.
21 SYMPTOM The unit powers up properly, lasers come on, but the unit does not scan and does not beep when a bar code is presented POSSIBLE CAUSE(S) SOLUTION Beeper disabled.
22 SYMPTOM Scanner beeps at some bar codes and NOT for others of the same bar code symbology POSSIBLE CAUSE(S) SOLUTION The print quality of the bar code is Check print mode.
23 Keyboard Wedge Only SYMPTOM The unit scans the bar code but there is no data POSSIBLE CAUSE(S) SOLUTION Configuration is not correct Make sure the scanner is configured for the appropriate mode.
24 RS-232 only SYMPTOM Power-up OK and scans OK but does not communicate properly to the host POSSIBLE CAUSE(S) SOLUTION Com port at the host is not working or Check to make sure that the baud rate an.
25 RS-232 Demonstration Program If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working.
26 Applications and Protocols The model number on each scanner includes the scanner number and communications protocol. Scanner Version Identifier Communication Protocol(s) 7100 41 RS-232/Light Pen re.
27 Appendix A Design Specifications Operational Light Source: VLD 675 ± 5nm, 0.681 milliwatts ( PEAK ) Depth of Field: 0 mm to 215 mm (0" to 8.5") at default (programmable) Scan Speed: 1200 scans/second Scan Pattern: 5 fields of 4 parallel lines (omnidirectional) Scan Lines: 20 Min Bar Width: 0.
28 Electrical Input Voltage: 5.2VDC ± 0.25V Power : 1.1 W Operating Current : 225 mA DC Transformers: Class II; 5.2 V @650 mA Laser Class: CDRH: Class IIa; EN 60 825-1: 1994/A11:1996 Class 1 EMC: FCC.
29 Appendix B Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages.
30 Parameter Default OCIA RS- Light IBM KBW 232* Pen 46XX DTS/NIXDORF * T T NCR F T T NCR S T T Poll Light Pen Source T T Beeper Tone Normal T T T T T T T T T T Beep/Transmit Sequence Before T T T T T.
31 Parameter Default OCIA RS- Light IBM KBW 232* Pen 46XX Transmit Codabar T T T T T T T T Start/Stop Characters CLSI Editing (Enable) T T T T T T T T Transmit Mod 43 Check Digit T T T T T T T T on Co.
32 Parameter Default OCIA RS- Light IBM KBW 232* Pen 46XX Two Digit Supplements T T T T as code T T T T 39 Five Digit Supplements T T T T as code T T T T 39 Bookland T T T T as code T T T T 39 977 (2 .
33 Appendix C Pin Assignments Pin Assignments for the PowerLink Cable The MS7100 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin modular plug of the PowerLink cable into the jack then connect the other end of the PowerLink cable to the host.
34 Pin Assignments for the PowerLink Cable Keyboard Wedge Interface The MS7100 Keyboard Wedge scanner interface terminates to a 10-pin modular jack. Connect the 10-pin modular plug of the PowerLink cable into the jack then connect the other end of the PowerLink Y-type cable to the host and keyboard (refer to page 7 for details).
35 Adapter Cable Connectors 5-pin Male 6-pin Female PowerLink Cable Connectors 5-pin Female 6 -pin Male Pin Assignments for the 5-pin DIN and 6-pin mini-DIN MS7100 Hand- Held Laser Scanner with Built-in PC Keyboard Wedge Interface The MS7100 Keyboard Wedge scanner interface terminates to a 10-pin modular jack.
36 Appendix D Warranty and Disclaimer Limited Warranty Products manufactured by Metrologic have a 2-year limited warranty from date of manufacture. This warranty is limited to repair, replacement or refund at Metrologic’s discretion. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey or Puchheim, Germany.
37 Disclaimer Metrologic Instruments, Inc. and the author or authors make no claims or warranties with respect to the contents or accuracy of this publication, or the product it describes, including any warranties of fitness or merchantability for a particular purpose.
38 Appendix E Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
39 Anmerkung Nach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte der Klasse A gemäß Teil 15 der Richtlinien der US-amerikanischen Bundesbehörde für das Fernmeldewesen entspricht.
40 Index A Accessories 2 AC input/outlet 2, 4, 5, 7 Adapter cable 2, 7, 35 Approvals 12 Assignments pin 33-35 Audible indicators 9 Authorized service center 36 Autodiscriminates 27 B Bar code 3, 8, 9,.
41 Light Pen 1, 2, 4, 6, 26, RDATA 33 33 Recommendation 7 Light source 27 Red led 3-6, 8, 9, 11, 20 List 2 Repair 10, 36 M property 36 Maintenance 19 Manufacturer’s recommendation 7 Mechanical 27 Mi.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic Instruments MS7100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic Instruments MS7100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic Instruments MS7100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic Instruments MS7100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic Instruments MS7100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic Instruments MS7100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic Instruments MS7100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic Instruments MS7100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.