Mercur y 6-5 Stat – Installation & User Guide Mercury 6-5 5 Channel Thermost at Inst allation Guide For Product: - PR0091 En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.
Mercur y 6-5 Stat – Installation & User Guide Table of Contents: THE MERCURY RANGE .................................................................................................................................... 3 Description ...............
Mercur y 6-5 Stat – Installation & User Guide The Mer cury Rang e From Resource Data Managemen t This documentation refers to the Mercury 6-5 - 5 Channel Thermostat Description The Mercury 5 Channel Thermostat ha s 5 thermostat f unctions.
Mercur y 6-5 Stat – Installation & User Guide Connections All connections are ma de to the back of the controller. The dia gram below shows the connection detail. Inputs and outputs are assigne d according to the chosen config uration. See Specification for further details on connectio ns.
Mercur y 6-5 Stat – Installation & User Guide Setting up the controller Access to the controller ca n be achieved several ways • Through the front mounted buttons • Direct access by PC or palm top into the rear co mms port. This requires a software package available on the RDM website • Through the RDM Data Directo r or Data Manager.
Mercur y 6-5 Stat – Installation & User Guide Recommended set-up method If you are not connecting to a network and want to set up the co ntroller through the buttons we recommend you use the following order from the function menu. rtc. Real time clock (This will automa tically synchronise on netw ork systems) a.
Mercur y 6-5 Stat – Installation & User Guide Parameter Tables: Parameter table for 5 Channel Thermosta t En sur e t ha t a ll po wer is Number Parameter Range o C ( o F ) Step Units Default P-01 Stat1 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.
Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range o C ( o F ) Step Units Default P-31 Stat4 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-32 Stat4 Diff 0 to 10 o C (32 to 50) 0.
Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range Step Units Default P79 Tuesday On Time 1 00:00 to 23:59 00:01 hh:m.
Mercur y 6-5 Stat – Installation & User Guide Network Configuration The final section to set-up is the network addres s. In all instance s, this mu st be done before the controller is plugged into the site network. The controllers have an aut o-initialise function, whic h will automatically log the device onto the site network.
Mercur y 6-5 Stat – Installation & User Guide Over-ride Operation The 5 Channel Thermostat can op erate either from its in ternal channel time settings or from a network Data Manager GP Timer channe l (P70 sets the mode either loca l or remo te).
Mercur y 6-5 Stat – Installation & User Guide Normal Operation During normal operation, the controlle r will display "on". If the 5 Channel Thermostat is on a network and on- line, the green network LED will be on . If any alarms are generated the r ed LED will light.
Mercur y 6-5 Stat – Installation & User Guide Thermostat Cooling/Heating Operation The diagrams below outline the operatio n of a channel when it is configured fo r he ating or cooling applications. In this instance the 5 Channel Thermo stat’s local timer is on.
Mercur y 6-5 Stat – Installation & User Guide Viewing Apart from setting up the controller, you can also view the status of the inputs a nd outputs. 1. IO. View Inputs / Outputs and States a. From the function menu, select “IO”, press enter b.
Mercur y 6-5 Stat – Installation & User Guide Network Alarms The table below shows the text and associated type numbe r that is se nt to the sy stem "front end".
Mercur y 6-5 Stat – Installation & User Guide Specification General Power requirements: Supply Voltage Range: 100 - 240 Vac ±10% Supply Frequency: 50 - 60 Hz ±10% Maximum supply current: <1 Amp (With no relay loads) Typical supply current: <0.
Mercur y 6-5 Stat – Installation & User Guide Inputs: Input resistance: 3.01K Ohms (for PTC or NTC type probes) Input type PT1000 NTC2000 N T C 2 k 2 5 Comms: RS232 with flow control En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.
Mercur y 6-5 Stat – Installation & User Guide Installation: Panel Cut-out: 72mm 93mm 34mm 17mm 2 holes: 3.5mm dia. Fixing: The controller can be fixed either by 2 X M3 screws fr om the re ar or by the plastic retaining de vice (PR0329), obtainable from RDM.
Mercur y 6-5 Stat – Installation & User Guide Wiring: Relay 4 and 5 N/O are fed from the supply input ! Note: Suitable mechanical restraints on the wi ring to the controller may be required; depen dant on cable types, to prevent undue stress or distorti on on the controlle r connectors.
Mercur y 6-5 Stat – Installation & User Guide Fuse: The host equipment must provide a suitable exter nal over-curre nt protection d evice such as: - Fuse: 6.
Mercur y 6-5 Stat – Installation & User Guide Revision History Revision Date Change s 1.0 27/10/2006 First Issue 1.1 01/03/2007 General Tidy Up 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mercury PR0091 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mercury PR0091 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mercury PR0091 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mercury PR0091 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mercury PR0091, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mercury PR0091.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mercury PR0091. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mercury PR0091 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.