INST ALLA TION AND OPERA TING INSTRUCTIONS FOR AQ-1 POWER VENT KIT DESIGNED FOR BOSCH 425 HN W A TER HEA TERS AQUAST AR 125 B W A TER HEA TERS INCLUDING AQUAST AR MODELS: 125HX • 125BS • 125X • 125BL T ABLE OF CONTENTS contents with an AQ-1 power vent p.
AQ-1 Power vent kit Parts included: Spillage Switch Kit 1. 185º F linear spillage switch mounted on an angled bracket and equipped with 36 inch cables connected to one eyelet terminal and one 1/4" quick connect terminal 2. Spillage switch mounting screw 3.
Power V ent Kit CAUTION 1. Failure to install, maintain and/or operate the Power V enter in accordance with manufacturer's instruction may result in conditions which can produce bodily injury and property damage.
INSTRUCTIONS ( SEE DIAGRAMS ABOVE ) 1. Mount gas pressure switch by securing it to the chosen location with a screw in each one of the four mounting holes. 2. Use a tube cutter to make a clean cut (not crimped) at each end of the two lengths of the 1/4" aluminum tubing.
e. Hand thread the pressure tap fitting into the heater's burner manifold. Use a small amount of an appropriate thread sealant on the male end of the fitting. Over tightening of the fitting will break it. f. Guide the end of the tube into the com- pression fitting.
1. The ECO is mounted on the lower left outlet water pipe. (See figure C) a. Remove one lead connecting to ECO terminal, it does not matter which one is disconnected. b. Attach 1/4" quick connect terminal end of linear spill switch cable to now exposed terminal of the ECO.
COMMON SETUP Mount gas pressure switch against wall 6 125B Model shown See Figure D, page 5 for location of Linear S pillage Switch V ent Hood (see freeze prevention information on page 2) Power vent motor 4" single wall pipe* (galvanized or stainless steel) or 4" B-type vent*.
CAUTION Failure to follow these installation instructions may violate applicable national and/or local codes The vent system must terminate so that proper clearances are maintained as cited in the National Fuel Gas Code, ANSI Z223.
INSTRUCTIONS (DO NOT BEGIN THESE PROCEDURES UNTIL VENT HOOD HAS BEEN INST ALLED) 1. Remove vibration mounts, nuts and washers from parts bag. Install on power venter as shown in (Figure H). 2. T o prevent vibration, securely support power venter from ceiling or joist using a plumber's strap or wire fastened to the vibration mounts.
3. Connect the RED wire from the jacketed cable onto the common terminal of the gas pressure switch. (See Figure I) NOTE: If the distance between the power venter and the gas pressure switch is greater than the length of the cable, splice a section of 2 conductor , PVC sheathed, 105º C thermostat cable to the supplied cable.
SAFETY INTERLOCK TEST 1. Open the gas supply to the water heater . 2. Remove the vent pipe from the vent connec- tor on the top of the water heater . 3. Block the vent connector with sheet metal or other noncombustible material. 4. Turn on the hot water supply to allow the burner to activate.
11 HEA TER ECO SAFET Y INTERLOCK DIAGRAM LINEAR LIMIT SPILLAGE SENSING SWITCH 185º MANUAL RESET BLACK.
1. Attach this template to the interior of the wall the V ent Hood will be penetrating. 2. Insure that proposed vent termination clear- ances are met before cutting opening through wall. Using a 1/2" drill bit, drill two pilot holes where noted on this template.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il AquaStar 125BS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del AquaStar 125BS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso AquaStar 125BS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul AquaStar 125BS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il AquaStar 125BS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del AquaStar 125BS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il AquaStar 125BS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo AquaStar 125BS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.