GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED W W W W W ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 84502 / REV . 10/2008 NA TURAL GAS W255F , W355F , W505F L.
READ CAREFULL Y BEFORE INST ALLING UNIT These installation instructions are a general guide, and do not supersede applicable local codes and ordinances. Before planning or making the installation, be sure it complies with all phases of the local heating codes.
1” 11” 2” SAFETY RULES A) The wall furnace should be located near the center of the house for best heat distribution. B) Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr .
ALL COMBUSTION AIR FROM OUTDOORS THROUGH SINGLE COMBUSTION AIR OPENING UL Listed V ent Cap UL Listed Gas V ent Opening Alternate Opening Location FIGURE D ALL COMBUSTION AIR FROM OUTDOORS THROUGH VENT.
VENTING This appliance must be properly connected to a venting system. Consult local ordinances governing venting. Install only UL listed type BW 4” oval gas vent. When the vent enters the attic, a listed type B-1 round flue pipe may be used. See Figure 2, Page 7.
ROUGH-IN INSTRUCTIONS NOTE: Maximum wall thickness for a dual wall (W505, W506) installation is 5-3/8”. STEP 1. Attach the base plate (purchased with the vent pipe) to the header plate using two No. 8 sheet-metal screws through the pre-punched holes.
ROUGH-IN INSTRUCTIONS NOTE: For proper combustion, make sure units are level, front to back and side to side. FIGURE 1 ROUGH-IN DIMENSIONS STEP 4. Remove double ceiling plate between studs. Install one ceiling plate spacer across the cut out in ceiling plate.
B-W VENT FIGURE 3 Casing “Z Bracket Front Panel Front Panel Door FIGURE 5C INST ALLA TION STEP 6. T o place furnace into position, grasp furnace and lift so furnace flue vent and header plate vent opening engage. Do not use burner or gas control to lift heater .
CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .
PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or thermocouple (see below). The pilot is unregulated so it will be operating at inlet line pressure (Max.
BBSK INST ALLA TION INSTRUCTIONS STEP 1 . Select left or right side of front panel for most convenient location of the temperature control knob. Remember to choose the side that allows adequate clearance for accessibility to adjust the control knob. STEP 2 .
BBSK INST ALLA TION INSTRUCTIONS Page 14 SIDE VIEWS / FRONT P ANEL 20-1/2” LEFT SIDE VIEW RIGHT SIDE VIEW FIGURE 9 BBSK CONTROL SWITCH 40225 SWITCH BRACKET 40230 HEA T SHIELD SENSING BULB FRONT P AN.
BBSK KIT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas.
Page 16 MODEL WFF81-C OPTIONAL F AN KIT INSTALLATION INSTRUCTIONS NOTE: This fan kit is to be installed after installation of wall furnace and with the wall furnace front panel in p l a c e .
Ground WHITE BLACK L2 White 1 15 V AC L1 Black 1 15 V AC BLACK F AN SWITCH BLACK BLACK BLACK MOTO R WHITE GREEN GROUND WIRE L2 White L1 Black 1 15 V AC 60 HZ - Less than 12 Amps. If any of the original wire as supplied with this appliance must be replaced, it must be replaced with type thermoplastic 105 degree C wire or its equivalent.
40542-A REAR REGISTER KIT ( Optional Accessor y) INST ALLA TION INSTRUCTIONS FOR GRA VITY VENTED W ALL FURNACES STEP 1. Cut hole within stud space behind heater in the back wall 8-1/4” high by 12-5/8” wide.
40542-A REAR REGISTER KIT - Continued INST ALLA TION INSTRUCTIONS FOR GRA VITY VENTED W ALL FURNACES Page 19 INNER P ANEL FIGURE 15 Plaster Ground Frame Closed Position Rear Register Grille 2”x4” .
TROUBLE SHOOTING CHAR T for qualified serviceman - MAIN BURNER SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too lar ge 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Burner won’t 1. Pilot flame too lar ge or too small. 1. Re-adjust pilot flame using adjustment on turn on combination control valve. 2. Dirt in pilot orifice. 2. Clean pilot orifice with air or solvent, do not ream.
SINGLE W ALL FURNACE Model Numbers Nat. L.P . W255F W256F W355F W356F DUAL W ALL FURNACE Model Numbers Nat. L.P . W505F W506F NOTICE: When ordering any component in the Burner Assembly , specify either Honeywell or Robertshaw components. REV . 06/2006 Prices and specifications subject to change without notice.
HOW T O PROPERL Y ORDER P AR TS: In addition to part description and part number , please give model number, serial number , and type of gas used. This information can be found on the rating plate that is attached to heater . Page 23 *TWO REQUIRED MARCH 2009 REVISED 06/2006 FO R M O DEL S R E F .
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HURT YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists.
LIMITED WARRANTY The L ouisville T in & Stove Co. w arrants to the or iginal user the acco mpanying pr oduct for the period speci fie d herein, pr ovide d said produc t is installed, ope rated, ma intained, service d, and used accordin g to the inst ruction s and specificatio ns accompan ying th e prod uct.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Louisville Tin and Stove W506F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Louisville Tin and Stove W506F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Louisville Tin and Stove W506F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Louisville Tin and Stove W506F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Louisville Tin and Stove W506F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Louisville Tin and Stove W506F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Louisville Tin and Stove W506F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Louisville Tin and Stove W506F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.