hi-efficient direct vent wall furnace INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 72903 / December 2003 MODEL NUMBERS NA T . GAS L.P . GAS HEDV403 HEDV404 - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2 Introduction…………………………….. 2 Specifications and Dimensions…………. 2 Safety Rules…………………………….. 3 Clearances……………………………….
SAFETY RULES 1. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, bodily injury , or death. 2. Use in other than a residential application may result in unsatisfactory performance and may void the warranty .
REFERENCE LETTER TO DRAWING CANADIAN INSTALLATIONS¹ A = Clearance above grade, veranda, porch, deck, or balcon y 12 Inches ( 30 cm) B = Clearance to win dow or door tha t may be ope n ed 12 Inches ( .
Page 5 CLEARANCES 1. As you face the heater , the clearance to a side wall on the right side is 0” (Fig. 1), and the left side is 1” (Fig. 2). 2. The minimum clearance from the top of the heater to the ceiling or any projecting overhang is 10”. (See Figure 3).
CLEARANCES 7. RESIDENTIAL GARAGE INST ALLA TION: Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18 inches (46 cm) above the floor . Y ou must build a platform 18” above floor , the full width and depth of the heater , including the rear trim kit.
INST ALLA TION Failure to follow these instructions carefully could result in poor performance, property damage, personal injury , or death. STEP 1. LOCA TE VENT OPENING (Requires 3-1/2” diameter wall opening) a) Select area on wall where heater will be installed.
INST ALLA TION - CONTINUED STEP 3 INST ALLING VENT SYSTEM 5” - 32” W ALL THICKNESS (12.7 cm - 81.3 cm) a) Use only factory supplied parts. Do not attempt to modify in any way . T o do so could cause a system imbalance resulting in poor performance and/or unsafe operating conditions.
STEP 5. INST ALLING REAR TRIM KIT a ) Secure right and left trim kit sides to the wall and trim kit brackets with eight #8 screws provided. See figure 1 1. The back of the heater should now be spaced 5” from the wall. b) Remove the temperature sensing unit from the back of the heater .
FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fir e or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is • If you cannot reach your gas supplier , call equipped with an ignition device which the fire department.
MODEL 0 t o 2,000’ 4,000’ 6,000’ 8,000’ - N O . 2,000’ 4,000’ 6,000’ 8,000’ 10,000’ NA TURAL GAS HEDV403 4 5 4 7 4 8 4 9 5 0 L.P . GAS HEDV404 5 5 5 5 5 6 5 6 5 7 PROPER BURNER FLAME The burner flame may be observed by raising the sight glass cover .
WIRING This appliance is equipped with a three prong grounding plug. For your protection against shock hazard, this ap- pliance should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the ground- ing prong from this plug.
STEP # STEP # 1) Thermostat calls for heat. 8) Continued... 2) Combustion fan turns on. return to Step 2. If after 3 attempts 3) Pressure switch closes. malfunction still occurs, furnace will 4) Power to Ignitor . go into lockout mode for one hour . 5) Ignitor warm up period.
HEVK-5 5’ VENT EXHAUST KIT INST ALLA TION INSTRUCTIONS W ARNING: Use only Louisville T in & Stove Company factory supplied parts and kits. Failure to do so could result in loss of life, personal injury , property damage, or unsatisfactory performance.
HEVE-5 VENT ENCLOSURE KIT INST ALLA TION INSTRUCTIONS STEP 1) Position end of Part No. 41610 enclosure body to heater trim kit where pipes exit trim kit, centering pipes inside body and attach to wall. W all anchors, not provided, may be required. Collector box may be behind HEVE-5 Kit.
MAINTENANCE INSTRUCTIONS For proper and safe operation keep furnace and furnace area clean. At regular intervals turn control valve to off, let cool and clean inside control and heat exchanger compartment.
TROUBLE SHOOTING CHAR T SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of valve. 1. Replace valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice - size and replace. 3. If installed above 2,000 ft.
TROUBLE SHOOTING CONTROL BOARD T o improve diagnosing and servicing, this control board is equipped with a self diagnosing green status light (see wiring diagram).
HI-EFFICIENT DIRECT VENT W ALL FURNACE Prices and specifications subject to change without notice. All prices are F .O.B. factory . Page 19 MODEL NUMBERS HEDV403 - NA T .
Page 20 MARCH 2005 HOW T O PROPERL Y ORDER P AR TS : In addition to part description and part number , please give model number, serial number , and type of gas used.
YOUR GAS CONTROL AND PILOT LIGHT SYSTEM Y our gas contr ol and pilot light system has a safety device whose purpose is to shut-off the gas supply to the appliance if the pilot light goes out. If you have trouble lighting the pilot or keeping it lit, it may mean that this safety device is warning you that there is a pr oblem with your system.
The Louisville T in & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Louisville Tin and Stove HEDV404 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Louisville Tin and Stove HEDV404 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Louisville Tin and Stove HEDV404 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Louisville Tin and Stove HEDV404 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Louisville Tin and Stove HEDV404, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Louisville Tin and Stove HEDV404.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Louisville Tin and Stove HEDV404. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Louisville Tin and Stove HEDV404 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.