Manuale d’uso / di manutenzione del prodotto SSS081 del fabbricante Lochinvar
Vai alla pagina of 20
Installa tion & Oper a tion Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119 T h i s ma n ua l m u s t o n ly b e us e d b y a qualified heating installer / serv ice technician. Read all instructions before installing. P erfor m steps in the order given.
Installation & Operation Manual 2 Hazar d definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Please r ead before pr oceeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation & Operation Manual Please r ead bef ore pr oceeding Installer – R ead all instructions before installing. P erform steps in the order give n. Ha ve this indir ect water heat er serv iced/inspected by a qualified service technician, at least annually .
Installation & Operation Manual 4 1 Gener al Infor mation The Lochin var SSS series indirect water heat er (FIG. 1-1) is designed to generate domestic hot water in conjunction with a hot water boiler using forc ed boiler water cir culation.
Installation & Operation Manual 5 Failure t o properly support the tank could result in property damage or personal injur y . W ARNING 2 Pre-installation 1. The installation must conform with the instructions in this manual and all applicable local, state, provincial, and national codes, la ws, regulations, and ordinances.
Installation & Operation Manual 6 Boiler Side Piping Figures 3-1 thru 3-3 show typical boiler side piping for several common situations. Regardless of which system is used it is imperative that the flo w rates called for in T able 3A on page 6 are developed thr ough the coil.
Installation & Operation Manual 7 SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNIO.
Installation & Operation Manual 8 3 Piping SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPI.
Installation & Operation Manual 9 3 Piping (continued) Figure 3-4 Multiple T ank Connections BOILER DOMESTIC HOT W ATER CIRCULATO R BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE ANTI-S.
Installation & Operation Manual 10 3 Piping Domestic Side Piping Basic Domestic Piping Figure 3-5 on page 12 sho ws ty pical domestic water piping for a tank. All c omponents ex cept the control are pr ovided by the installer . The function of the components shown are as follows: a.
Installation & Operation Manual 11 3 Piping (continued) W hen no fixtures are dra wing water , the br onze cir culator mov es hot water from the tank t o the end of the branch just below the last fixtur e, then back to the inlet of the tank v ia the return pipe.
Installation & Operation Manual 12 3 Piping Figure 3-5 Recommended Domestic Water Piping.
Installation & Operation Manual 13 4 W iring Indirect Water Hea ter Sensor Setup (Knight Boiler) Label all wires prior to disconnection when serv icing controls. W ir ing errors can cause improper and dangerous operation. CAUTION 1. Install the sensor inside the tank as depicted in FIG.
Installation & Operation Manual 14 4 W iring IDW Contr olled Using Aquastat and Zone Circulator / V alv e 1. Install A quastat to tank. A quastat contr ol (TST1085) can be ordered from y our local Lochin var dist ributor . 2. Connect A quastat to the zone c ontroller for the I ndirect W ater Heat er Zone.
Installation & Operation Manual 15 5 Star t-up and Check-out 1. Make sure the syst em is free of leaks and that air is purged from the system. CAUTION Fix any leaks found befor e proc eeding further . Leakage from the boiler piping can result in sever e damage to the boiler .
LIM IT ED LIFETIME INDIRECT W A TER HEA TER W ARRANTY WHA T DOES THIS LIMITED W ARRANTY COVER? This limited lifetime warranty covers the stainless steel tank, stainless steel heat exchanger coil and component parts for leakage or other malfunction caused by defects in materials and/or workmanship.
LIM ITE D LIFETIME INDIRECT W A TER HEA TER W ARRANTY (CONTINUED) ©–12/06—Printed in U.S.A. WHA T WILL WE DO T O CORRECT PROBLEM? If a defect occurs within the warranty period, we will: 1.
18 Notes.
19 Notes.
Revision Notes: Revision B (SSS-I&O-Rev B) reflects edits and additions made to the piping diagrams. Revision C (SSS-I&O-Rev C) reflects edits made to the piping diagrams, the DHW T ank Sensor (AUX) and the addition of the warranty . Revision D (ECO #C02870) reflects the addition of the scald chart on page 3.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lochinvar SSS081 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lochinvar SSS081 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lochinvar SSS081 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lochinvar SSS081 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lochinvar SSS081, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lochinvar SSS081.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lochinvar SSS081. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lochinvar SSS081 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.