POWER FEED ® 25M SVM185-A July , 2008 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part.
SAFETY i i i i Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
SAFETY i i i i i i i i Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FUMES AND GASES can be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. A void breathing these fumes and gases.When welding, keep your head out of the fume.
S S A A F F E E T T Y Y i i i i i i i i i i i i Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Jan ‘07 FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment.
S S A A F F E E T T Y Y i i v v i i v v Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Mar ‘93 PRÉCAUTIONS DE SÛRETÉ P our votre propre protection lire.
SAFETY v v Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Electroma gnetic Compatibility (EMC) Conf or mance Products displa ying the CE m.
SAFETY vi vi Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Electr omagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the str ucture of the building and other activities that are taking place.
- MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - I I PO WER FEED® 25M RETURN TO MAIN INDEX P age Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS - INST ALLA TION SECTION A-1 A-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INST ALLA TION A-2 A-2 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T O.
INST ALLA TION A-3 A-3 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SAFETY PRECA UTIONS ELECTRIC SHOCK CAN KILL.
INST ALLA TION A-4 A-4 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC CONTROL CABLE CONNECTION: Digital Control Cable: Figure A.
INST ALLA TION A-5 A-5 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC WELD CABLE SIZE T able A.1 located belo w are copper cab le sizes re com- mended f or diff erent currents and duty cycles .
INST ALLA TION A-6 A-6 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SHIELDING GAS CONNECTION CYLINDER may explode if damaged.
INST ALLA TION A-7 A-7 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T O.
INST ALLA TION A-8 A-8 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC WIRE DRIVE CONFIGURA TION (See Figure A-6) Changing the Gun Receiver Bushing ELECTRIC SHOCK can kill.
INST ALLA TION A-9 A-9 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC REMO TE SENSE LEAD SPECIFICA TIONS W elding with Multiple Arcs: ( See Figure A.
INST ALLA TION A-10 A-10 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T.
T ABLE OF CONTENTS - OPERA TION SECTION B-1 B-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERA TION B-2 B-2 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC • ELECTRIC SHOCK CAN KILL.
OPERA TION B-3 B-3 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Re.
OPERA TION B-4 B-4 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Re.
OPERA TION B-5 B-5 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 1 3 2 5 4 6 9 14 15 16 8 11 12 13 10 7 FIGURE B.
OPERA TION B-6 B-6 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC LED condition Steady green Blinking green.
OPERA TION B-7 B-7 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Re.
OPERA TION B-8 B-8 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Re.
OPERA TION B-9 B-9 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NON-SYNERGIC GMA W AND FCA W WELDING (See Figure B.
OPERA TION B-10 B-10 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 300 25.
OPERA TION B-11 B-11 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC GMA W (MIG) SYNERGIC WELDING Synergic welding allows for easy procedure setting.
OPERA TION B-12 B-12 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Synergic CV programs feature an ideal voltage best suited f or most procedures.
OPERA TION B-13 B-13 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-14 B-14 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-15 B-15 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Steel and Stainless GMA W -P (Pulsed MIg)Display 220 1.
OPERA TION B-16 B-16 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-17 B-17 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-18 B-18 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-19 B-19 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PULSE PULSE-ON-PULSE FREQUENCY: FREQ.
OPERA TION B-20 B-20 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-21 B-21 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC GMA W -STT™ W aveform Control T echnology™ maximizes the ability to modify the arc for the perf ect weld.
OPERA TION B-22 B-22 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PEAK CURRENT (Figure B.16) P eak current controls the arc length, which also aff ects the shape of the root.
OPERA TION B-23 B-23 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC No Foot / Hand Amptrol 1. Adjust the arc amperage with the left knob on the displa y panel.
OPERA TION B-24 B-24 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-25 B-25 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SET -UP FEA TURES MENU The Setup Menu gives access to the set-up configura- tion.
OPERA TION B-26 B-26 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC P .0 Press the left button to exit the set-up menu.
OPERA TION B-27 B-27 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC P .8 TIG Gas Control (T wo Settings) 1.
OPERA TION B-28 B-28 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC P .99 Show T est Modes Many weld tables include special modes f or testing and ser vicing the welding system.
OPERA TION B-29 B-29 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC USER MEMORIES Recall a memory with memor y buttons T o recall a user a memor y , press one of the six user memor y buttons .
OPERA TION B-30 B-30 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC T o set limits, press the desired memor y button 1-6 and hold f or 5 seconds.
OPERA TION B-31 B-31 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC F our items show on the MSP4 panel.
OPERA TION B-32 B-32 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-33 B-33 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC COLD FEED/GAS PURGE SWITCH Cold F eed and Gas Purge are combined into a sin gle s pr ing cent ered togg le s witch.
OPERA TION B-34 B-34 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-35 B-35 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC EXAMPLE 2 - 2 STEP TRIGGER: Improv ed Arc Star t and Arc End.
OPERA TION B-36 B-36 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC WELD: After upslope, the power source output and the wire f eed speed continue at the weld settings.
OPERA TION B-37 B-37 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-38 B-38 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC EXAMPLE 5 - 4 STEP TRIGGER: Manual control of Star t and Crater times with Bur nback ON.
OPERA TION B-39 B-39 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC .
OPERA TION B-40 B-40 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FLO W METER The flo wmeter sho ws the flow rate of shielding gas and has a valv e to adjust the flow .
T ABLE OF CONTENTS - ACCESSORIES SECTION C-1 C-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACCESSORIES C-2 C-2 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC WIRE TYPE Steel Wires: Cored Wires: Aluminum Wires: ELECTRODE SIZE .
ACCESSORIES C-3 C-3 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC R.
ACCESSORIES C-4 C-4 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC R.
ACCESSORIES C-5 C-5 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC K1500-5 K489-7 K2339-1 K590-6 K435 K468 K659-1 3000290 K586-1 Gun Receiver Bushing (compatible with Oxo® guns.
ACCESSORIES C-6 C-6 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC INST ALL A T ION OF THE K590- 6 W A TE R COOLING KIT ELECTRIC SHOCK can kill.
ACCESSORIES C-7 C-7 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC ELECTRIC SHOCK can kill. • T urn the input power OFF at the disconnect switch before working on this equipment.
Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES C-8 C-8 PO.
T ABLE OF CONTENTS - MAINTENANCE SECTION D-1 D-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE D-2 D-2 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC ELECTRIC SHOCK can kill. • Do not operate with co vers removed.
T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VO LTA G E SENSE LEAD #67A LEAD #67 PUSH PULL DAUGHTER DRIVE MOTOR GEAR BOX AND CONDUCTOR BLOCK FEEDBACK T ACH ST A TUS LED GUN TIGGER AND DUAL PROCEDURE RECEPT ACLE 2-STEP/ 4-STEP CONTROL BOARD FEEDH.
THEOR Y OF OPERA TION E-3 E-3 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Mas.
THEOR Y OF OPERA TION E-4 E-4 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC CONTROL BOX (USER INTERF ACE) The POWER FEED® 25M wire feeders do not hav e User Interface Boards in the control box.
TROUBLESHOOTING E-5 E-5 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC COMPONENT ST A TUS LIGHTS Each network component has a single status light.
TROUBLESHOOTING E-6 E-6 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T .
T ABLE OF CONTENTS - TROUBLESHOOTING AND REP AIR F-1 F-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING AND REP AIR F-2 F-2 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC This T roubleshooting Guide is provided to help you locate and repair possible machine malfunctions.
TROUBLESHOOTING AND REP AIR F-3 F-3 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Sometimes machine failures appear to be due to PC board failures .
FUNCTION PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do no.
FUNCTION PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do no.
OUTPUT PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not .
OUTPUT PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not .
FUNCTION PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do no.
FUNCTION PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do no.
FUNCTION PROBLEMS Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do no.
ArcLink System Error Codes Obser ve Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y.
Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-12 F-12 .
Ser vice and repair should be perf or med b y only Lincoln Electric f actor y trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warranty .
23 4 5 2 J1 J2 FIGURE F .1 – PLUG J1 AND J2 LOCA TIONS VOL T AGE SENSE PC BOARD TEST (continued) PROCEDURE 1. Remov e input power from the wire feed unit. 2. Using the 3/8 in. nut dr iver , remove the cov er from behind the wire reel. 3. Locate the voltage sense PC board and plugs J1 and J2.
Ser vice and repair should be perf or med b y only Lincoln Electric f actor y trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warranty .
BLUE Black RED J84 FIGURE F .2 – PLUG J84 LOCA TION T ACH FEEDBACK TEST (continued) TROUBLESHOOTING AND REP AIR F-16 F-16 PO WER FEED® 25M Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1.
Ser vice and repair should be perf or med b y only Lincoln Electric f actor y trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warranty .
1 4 2 5 6 3 #550 #551 FIGURE F .3 – QUICK CONNECTOR #550 AND #551 LOCA TIONS DRIVE MOTOR TEST (continued) PROCEDURE 1. Remov e input power to wire feed unit. 2. Using the 3/8 in. nut driver , remov e the cov er from the wire feeder . 3. Locate the two quick connectors in the two motor ar mature leads.
Ser vice and repair should be perf or med b y only Lincoln Electric f actor y trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warranty .
THUMB THUMB S CREW SCREW CONDUIT CONDUIT E LECTRODE ELECTRODE CABLE CABLE G UN GUN BUSHING BUSHING WATER WATER HOSES HOSES WATER WATER HOSE HOSE FIGURE F .
GEAR BOX REMOV AL AND DRIVE MOTOR REMOV AL AND REPLACEMENT PROCEDURE (continued) TO REMOVE THE DRIVE MOTOR FROM THE GEAR BOX: 10. Using the slot head screwdriver , remov e the gear box inspection co ver nearest to the dr ive motor . 11. Using the 5/16 in.
Return to Section T OC Return to Section T OC Retur n to Section T OC Return to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-22 F-22 .
T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER FEED® 25M Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL DIA GRAMS G-2 PO WER FEED® 25M WIRING DIA GRAM - COMPLETE MACHINE - CODE 11313 (G5585) - + PO W ER ARC LI NC RECE PT ACL E A B C D E 54 1 L6 54 0B 54 0A 6 4 0 A BRI DG E RECT I FI ER 5 5 4.
Return to Section TOC Return to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-3 PO.
Return to Section TOC Return to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-4 PO WER FEED® 25M SCHEMA TIC - 42 V AC & ARCLINK FEEDER PC BO ARD #1 (G3883-2) G-4 NOTE: This diagr am is for reference only .
Return to Section TOC Return to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-5 PO WER FEED® 25M SCHEMA TIC - 42 V AC & ARCLINK FEEDER PC BO ARD #2 (G3883-2) G-5 NOTE: This diagr am is for reference only .
Return to Section TOC Return to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-6 PO WER FEED® 25M SCHEMA TIC - MSP4 OPTIONAL DISPLA Y PC BOARD (G4456) G-6 NOTE: This diagr am is for reference only .
ELECTRICAL DIA GRAMS G-7 PO WER FEED® 25M SCHEMA TIC - SPI DISPLA Y PC BOARD - (L11756) y ( y y ) g R i i A S STANDARD This print is Current G-7 NOTE: This diagr am is for reference only . It ma y not be accurate for all machines cov ered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liab lilities resulting from board level troubleshooting. PC Board repairs will invalidate your f actory warranty . Individual Printed Cir cuit Board Components are not available fr om Lincoln Electric.
Return to Section TOC Return to Section TOC Return to Section TOC Retur n to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIA GRAMS G-9 PO WER FEED® 25M SCHEMA TIC - V OL T AGE SENSE SELECT PC BO ARD - (S24779) G-9 NOTE: This diagr am is for reference only .
NOTE: Lincoln Electric assumes no responsibility for liab lilities resulting from board level troubleshooting. PC Board repairs will invalidate your f actory warranty . Individual Printed Cir cuit Board Components are not available fr om Lincoln Electric.
ELECTRICAL DIA GRAMS G-11 PO WER FEED® 25M SCHEMA TIC - SPOOL GUN PC BOARD (L12008) G-11 NOTE: This diagr am is for reference only . It ma y not be accurate for all machines cov ered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liab lilities resulting from board level troubleshooting. PC Board repairs will invalidate your f actory warranty . Individual Printed Cir cuit Board Components are not available fr om Lincoln Electric.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lincoln Electric POWER FEED SVM185-A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lincoln Electric POWER FEED SVM185-A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lincoln Electric POWER FEED SVM185-A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lincoln Electric POWER FEED SVM185-A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lincoln Electric POWER FEED SVM185-A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lincoln Electric POWER FEED SVM185-A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lincoln Electric POWER FEED SVM185-A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lincoln Electric POWER FEED SVM185-A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.