Po wer F eed 11 SemiAutomatic Cabinet W ire Feeder OPERA TOR’S MANUAL IM613-B October, 2000 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’ s recommendations.
iv SAFETY iv PR É CA UTIONS DE S Û RET É Pour votre propre protection lire et observer toutes les instructions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suiv- antes: S û ret é Pour Soudage A L ’ Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications .........................................................................
Page Troubleshooting ..............................................................................................Section E Safety Precautions ...........................................................................................................
A-1 INST ALLA TION POWER FEED 11 A-1 TECHNICAL SPECIFICA TIONS – P o wer Feed 11 COMPLETE UNITS SPEC.# TYPE LOW SPEED RATIO HIGH SPEED RATIO The PF-11 is environmentally rated IP21S per IEC60529 Wire Size Wire Size Speed Solid Cored Speed Solid Cored K1635-1 Power Feed 11 50-625 IPM .
A-2 INST ALLA TION POWER FEED 11 A-2 SAFETY PRECA UTION WIRE FEEDER T O PO WER SOURCE CONFIGURA TIONS The Wire Feeder is equipped to operate in the vertical or horizontal position.
A-3 INST ALLA TION POWER FEED 11 A-3 CABLE CONNECTIONS CONTROL CABLE CONNECTIONS • All system control cables are the same. • All control cables can be connected end to end to extend their length. • All system equipment must be connected to a con- trol cable.
A-4 INST ALLA TION POWER FEED 11 A-4 WORK CABLE CONNECTIONS Connect a work lead of sufficient size and length (per the following table) between the proper output termi- nal on the power source and the work. Be sure the connection to the work makes tight metal-to-metal electrical contact.
A-5 INST ALLA TION POWER FEED 11 A-5 RATIO CHANGE PROCEDURE: 1) Power down the Power Feed by turning OFF its companion PowerWave power source. For maxi- mum safety, disconnect the control cable from the Power Feed. 2) Pull open the Wire Feeder ’ s Compartment Door.
A-6 INST ALLA TION POWER FEED 11 A-6 FIGURE A.3 DIP SWITCH SETUP SETTING DIP SWITCHES IN THE CONTROL BO X There are two DIP switch banks on the mother board of the Control Box. They are labeled S1 and S2 and are located and oriented as shown in Figure A.
A-7 INST ALLA TION POWER FEED 11 A-7 SETTING DIP SWITCHES IN THE WIRE DRIVE There is one DIP switch bank on the control board of the wire drive. It ’ s labeled S1 and is located and ori- ented as shown in Figure A.
A-8 INST ALLA TION POWER FEED 11 A-8 WIRE FEED DRIVE R OLL KITS AND F AST -MA TE ™ GUN AD APTER GUIDE TUBES NOTE: The maximum rated solid and cored wire sizes and selected drive ratios are shown on the SPECIFICATIONS in the front of this section. The electrode sizes that can be fed with each drive roll and wire guide are stenciled on each part.
A-9 INST ALLA TION POWER FEED 11 A-9 7) Insert inner Wire Guide, groove side out, over the two locating pins in the feed plate. 8) Install each drive roll by pushing over shaft until it butts up against locating shoulder on the drive roll shaft. (Do Not exceed maximum wire size rating of the wire drive).
A-10 INST ALLA TION POWER FEED 11 A-10 LIFTING HANDLE The Power Feed 11 is shipped with a insulated Lifting Handle which can be mounted on the top or back of the Wire Feeder. This handle is intended to be primar- ily used for short term carrying of the Feeder.
A-11 INST ALLA TION POWER FEED 11 A-11 OPTIONAL FEA TURES INST ALLA TION A number of Optional Features are available for use with Power Feed 11. Some Installation informa- tion is provided in this section, REFER TO THE INSTRUCTIONS THAT COME WITH EACH KIT FOR DETAILED INFORMATION REGARDING INSTALLA- TION.
B-1 OPERA TION POWER FEED 11 B-1 SAFETY PRECA UTIONS PR ODUCT DESCRIPTION The Power Feed 11 is a high performance, digitally controlled, modular cabinet style wire feeder. Properly equipped, it can support the GMAW, GMAW- P, FCAW, and SMAW processes. The Power Feed wire feeders are designed to be a part of a modular, multi process welding system.
B-2 OPERA TION B-2 The user adjusts WFS according to factors such as weld size, penetration requirements, heat input, etc. The power source then uses the WFS setting to adjust its output char- acteristics (output voltage, output current) according to pre- programmed settings contained in the power source.
B-3 OPERA TION B-3 K1542-12 MSP2 Panel: (Optional) This panel provides a selection of over 25 weld modes, including CV, pulse, FCAW and CC, through a toggle switch and indicator lights (LEDs).
B-4 OPERA TION B-4 To recall a memory setting, simply push that memory button. That memory ’ s contents will be immediately recalled to the Control box.
B-5 OPERA TION B-5 CONTROL BO X -- SETTING OPERA TING LIMITS Upper and lower operating limits can be set for the WFS/Amps setting and the Volts/Trim setting. Doing so requires knowledge of how to set the limits, and access to the PC board in the Control Box.
B-6 OPERA TION B-6 WIRE DRIVE OPERA TION The most frequently used Wire Drive settings are external; some features are accessed by internal set- tings. WIRE DRIVE SETTINGS -- EXTERNAL 2 STEP/4 STEP SWITCH: The Wire Drive has a 2 Step/ 4 Step switch located near the gun connector.
B-7 OPERA TION B-7 WIRE DRIVE -- PC BO ARD ADJUSTMENTS ELECTRODE POLARITY: The system needs to be aware of the electrode polari- ty. A DIP switch setting on the Wire Drive PC board is used for this purpose. See INSTALLATION Section “ Setting DIP Switches in the Wire Drive ” .
B-8 OPERA TION B-8 FEEDING ELECTR ODE AND BRAKE ADJUSTMENT 1) Turn the Reel or spool until the free end of the electrode is accessible. 2) While tightly holding the electrode, cut off the bent end and straighten the first 6" (150 mm). Cut off the first 1" (25 mm).
B-9 OPERA TION B-9 MAKING A WELD 1. Use only a network compatible power source. 2. Properly connect the electrode and work leads for the correct electrode polarity. 3. Set all desired parameters such as trigger logic, Run-in Speed, Acceleration, Electrode polarity, etc.
B-10 OPERA TION B-10 COMPONENT ST A TUS LIGHTS Each network component has a single status light. The light is a bicolor, Green/Red, LED. The purpose of the status light is to allow the operator to quickly identify that the system is working properly or, if not, which component is causing the problem.
B-11 OPERA TION B-11 POWER FEED 11 ST A TUS LIGHT ST A TES (CON ’ T) LED State Red LED blinking at a fast rate Red LED ON and steady Green LED ON and steady Power Source LED Power source needs to be reprogrammed. Contact your Local Authorized Lincoln Field Service Facility.
TABLE C.1 – DRIVE ROLL AND GUIDE TUBE KITS Wire Size 4-Roll Drive (4-Driven) Solid Steel Electrode 0.023 ” - 0.025 ” (0.6 mm) KP1505 - 030S 0.030 ” (0.8 mm) KP1505 - 030S 0.035 ” (0.9 mm) KP1505 - 035S 0.040 ” (1.0 mm) KP1505 - 045S* 0.045 ” (1.
C-2 A CCESSORIES C-2 DESCRIPTION OF OPTIONAL CON- TR OL BO X P ANELS A number of Optional Features are available for use with Power Feed 11. Some Installation information is provided in this section, REFER TO THE INSTRUC- TIONS THAT COME WITH EACH KIT FOR DETAILED INFORMATION REGARDING INSTALLATION.
C-3 A CCESSORIES C-3 WIRE SPINDLE AD APTERS K435 - Permits 14 lb. (6 kg) Innershield coils to be mounted on 2" (51 mm) O.D. spindles. K363P - Adapts Lincoln Readi-Reel coils of electrode 30 lb. (14 kg) and 22 lb. (10 kg) to a 2" (51 mm) spin- dle.
D-1 MAINTENANCE D-1 POWER FEED 11 A v oiding Wire Feeding Prob lems Wire feeding problems can be avoided by observing the following gun handling and feeder set up proce- dures: a) Do not kink or pull cable around sharp corners. b) Keep the electrode cable as straight as possible when welding or loading electrode through cable.
E-1 TR OUBLESHOO TING E-1 POWER FEED 11 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TR OUBLESHOO TING E-3 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TR OUBLESHOO TING E-5 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-6 TR OUBLESHOO TING E-6 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-7 TR OUBLESHOO TING E-7 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-8 TR OUBLESHOO TING E-8 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-9 TR OUBLESHOO TING E-9 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-10 TR OUBLESHOO TING E-10 POWER FEED 11 Observe all Safety Guidelines detailed throughout this manual Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.
E-11 TR OUBLESHOO TING E-11 POWER FEED 11 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-12 TR OUBLESHOO TING E-12 POWER FEED 11 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 POWER FEED 11 45 6 559 512A 512 558 56 4 1 2 512 557 512 557 558 556 558 556 559 6 P11 P13 1 3 A 3 4 A 12 5 1 6 4 CAVITY NUMBERING SEQUENCE (AS VIEW ED FROM LEAD SIDE OF CONNECTOR) B.
F-2 DIA GRAMS F-2 POWER FEED 11 6 3 1 2 3 4 500 7 P.C. BOARD ENCODER DUAL LOWER 1 2 1 4 3 4 3 2 43 34 2 1 540A 500A 542A 541A 12 6 2 1 1 512C 2 500C 555 1 556 553 3 2 554 4 1 1 5 6 3 (J1) N.F. (J1) N.F. N.C. STATUS LED RED/GREEN W B 7 8 511 560 561 559 562 563 500D 557 500E 558 512A 555 556 553 (J1) 554 N.
F-3 DIA GRAMS F-3 POWER FEED 11 1.29 2.01 8.66 2.13 (MOUNTING HOLES ON BRACKET) 7.34 .38 3.90 3.10 15.71 17.96 .68 1.18 19.59 16.84 28.69 18.02 18.52 .
NO TES POWER FEED 11.
Now A vailable...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER ’ S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER ’ S SAFETY PRACTICES.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lincoln Electric IM613-B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lincoln Electric IM613-B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lincoln Electric IM613-B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lincoln Electric IM613-B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lincoln Electric IM613-B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lincoln Electric IM613-B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lincoln Electric IM613-B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lincoln Electric IM613-B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.