Manuale d’uso / di manutenzione del prodotto 180 del fabbricante Lincoln Electric
Vai alla pagina of 42
LINCOLN ELECTRIC • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 .b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.
PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1.
v INST ALLA TION POWER MIG (140, 180 MODELS) v EN 60974-10.
vi INST ALLA TION POWER MIG (140, 180 MODELS) vi EN 60974-10:.
vii vii T T h h a a n n k k Y Y o o u u for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
viii viii T ABLE OF CONTENTS Page –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation .
A-1 INST ALLA TION POWER MIG (140, 180 MODELS) A-1 TECHNICAL SPECIFICA TIONS 180 Amp units (K2472-1 180T , K2473-1 180C) INPUT – SINGLE PHASE ONL Y RA TED OUTPUT OUTPUT Standard Voltage/Frequency In.
2 Requirements For Maximum Output In order to u tilize th e maximum output capabi lity of the machine, a branch circuit capable of 25 amps at 120 volts, 60 Hertz is required.
A-3 INST ALLA TION POWER MIG (140, 180 MODELS) A-3 SELECT SUIT ABLE LOCA TION Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front of the unit.
A-4 INST ALLA TION POWER MIG (140, 180 MODELS) A-4 INCLUDED COMPONENTS • Wire Feeder Welder. • Work Cable & Clamp. • Magnum 100L Welding Gun. • 3 .035” (0.9mm) Contact Tips (1 installed on the welding gun). • 3 .025” (0.6mm) Contact Tips.
B-1 OPERA TION B-1 POWER MIG (140, 180 MODELS) COMMON WELDING ABBREVIA TIONS GMAW (MIG) • Gas Metal Arc Welding FCAW (Innershield or Outershield) • Flux Core Arc Welding PRODUCT DESCRIPTION (PRODUCT CAP ABILITIES) These small portable wire feed welders are capable of MIG welding on steel, stainless steel, and aluminum.
B-2 OPERA TION B-2 POWER MIG (140, 180 MODELS) CONTROLS AND SETTINGS This machine has the following controls: See Figure B.1 1. POWER SWITCH – Turns power on and off to the machine. 2. ARC VOL TAGE CON TROL – This knob s ets the output voltage of the machine.
B-3 OPERA TION B-3 POWER MIG (140, 180 MODELS) See Figure B.3 8 . WELDING GUN CONNECTOR BUSHING & THUMBSCREW – Provides electrical power to the welding gun. The thumbscrew holds the welding gun into the connector block. (Front of Machine, Side Door and Wire Drive Cover have been removed for clarity of Items 8 and 9).
B-4 OPERA TION B-4 POWER MIG (140, 180 MODELS) TABLE B.1 DRIVE ROLL AND WIRE GUIDES Wire Diameter & Type .025”(0.6mm) MIG wire .030”(0.8mm) MIG wire .035”(0.9mm) MIG wire .030”(0.8mm) flux-cored .035”(0.9mm) flux-cored .045”(1.1mm) flux-cored Drive Roll .
B-5 OPERA TION B-5 POWER MIG (140, 180 MODELS) A. ITEMS NEEDED FOR FLUX CORED WELDING 1. 035”(0.9mm) Contact Tip 2. .025”-.035”(0.6mm-0.9mm) wire guide 3. Knurled Drive Roll 4. .035”(0.9mm) NR-211MP Flux-Cored Wire 5. Black Flux Cored gun nozzle 6.
B-6 OPERA TION B-6 POWER MIG (140, 180 MODELS) B. CONNECT LEADS AND CABLES ON THE MACHINE (See Figure B.7) 1. Open the case side door 2 . Slide the connector end of the gun and cable through the hole in the machine front and into the gun connector bushing on the wire drive.
B-7 OPERA TION B-7 POWER MIG (140, 180 MODELS) ( See Figure B.9) 9. Feed the wire through the wire drive inlet along the inner wire guide groove and into the wire drive outlet on the gun side. 10. Close the top drive roll pressure arm and secure by pivoting the tension adjustor back to the up position.
B-8 OPERA TION B-8 POWER MIG (140, 180 MODELS) A. ITEMS NEEDED FOR MIG WELDING 1. 025”(0.6mm) Contact Tip 2. 025”-035”(0.6mm-0.9mm) Inner wire guide 3. .025”(0.6mm) Drive Roll 4. .025”(0.6mm) SuperArc L-56 Solid MIG Wire 5. Brass gun nozzle .
B-9 OPERA TION B-9 POWER MIG (140, 180 MODELS) B. INST ALL SHIELDING GAS MIG welding requires an appropriate bottle of shielding gas. For mild steel either a cylinder bottle of Ar/CO 2 or 100% CO 2 can be used refer to the following instruc- tions to properly connect shielding gas to the machine.
B-10 OPERA TION B-10 POWER MIG (140, 180 MODELS) C . CONNECT LEADS AND CABLES ON THE MACHINE (See Figure B.14) 1. Open the case side door. 2 . Slide the connector end of the gun and cable through the hole of the machine front and into the gun connector bushing on the wire drive.
B-11 OPERA TION B-11 POWER MIG (140, 180 MODELS) (See Figure B.16) 9. Feed the wire through the wire drive inlet along the inner wire guide groove and into the wire drive out- let on the gun side. 10. Close the top drive roll pressure arm and secure by pivoting the tension adjustor back to the up position.
B-12 OPERA TION B-12 1. Follow the MIG welding steps in the previous sec- tion. 2. Connect a bottle of 100% Argon shielding Gas per previous section. 3. Disconnect Magnum 100L Gun. 4. Install optional K2532-1 Magnum 100SG spool gun per instructions included with gun.
C-1 ACCESSORIES C-1 POWER MIG (140, 180 MODELS) K2525-1 - Spot Timer Kit Timer kit, when turned on, allows you to set a fixed weld time so that when the gun trigger is pulled the machine will weld for a fixed time period up to 10 sec- onds.
C-2 ACCESSORIES C-2 POWER MIG (140, 180 MODELS) 3-3/4" (95.3mm) 4"(102mm) 16"(406.4mm) 3-11/16" 8-1/16" 3-13/32" 9/32"(7.
C-3 ACCESSORIES C-3 POWER MIG (140, 180 MODELS) 2-15/16"(74.6mm) 3-3/16"(81mm) 7-9/16"(192.1mm) 1-1/2"(38.1mm) 13-1/2"(342.9mm) 1-1/4"(31.
D-1 MAINTENANCE D-1 POWER MIG (140, 180 MODELS) MAINTENANCE SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Disconnect input power by removing plug from receptacle before working inside POWER MIG (140, 180 MODELS). Use only grounded receptacle. Do not touch electrically “hot” parts inside POWER MIG (140, 180 MODELS).
D-2 MAINTENANCE D-2 POWER MIG (140, 180 MODELS) GUN AND CABLE MAINTENANCE FOR MAGNUM™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg ) of fl ux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor.
D-3 MAINTENANCE D-3 POWER MIG (140, 180 MODELS) GUN HANDLE P ARTS The gu n handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches a stop.
E-1 TROUBLESHOOTING E-1 POWER MIG (140, 180 MODELS) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your CAUTION This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions.
E-2 TROUBLESHOOTING E-2 POWER MIG (140, 180 MODELS) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your CAUTION PROBLEMS (SYMPTOMS) Major physical or electrical damage is evident.
E-3 TROUBLESHOOTING E-3 POWER MIG (140, 180 MODELS) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your CAUTION PROBLEMS (SYMPTOMS) No wire feed when gun trigger is pulled.
E-4 TROUBLESHOOTING E-4 POWER MIG (140, 180 MODELS) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your CAUTION PROBLEMS (SYMPTOMS) Arc is unstable – Poor starting POSSIBLE CAUSE 1.
F-1 DIAGRAMS F-1 POWER MIG (140, 180 MODELS) WIRING DIAGRAM FOR CODES 1 1254, 1 1255, 1 1256 AND 1 1257 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
F-2 DIAGRAMS F-2 POWER MIG (180 MODELS) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
F-3 DIMENSION PRINT F-3 POWER MIG (140, 180 MODELS) 10.35”(262.9mm) 18.78”(477mm) 14.08”(357.6mm).
NOTES POWER MIG (140, 180 MODELS).
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTIO N FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lincoln Electric 180 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lincoln Electric 180 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lincoln Electric 180 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lincoln Electric 180 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lincoln Electric 180, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lincoln Electric 180.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lincoln Electric 180. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lincoln Electric 180 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.