P OWER P ROTECTION UPSta tion GXT ™ 6 kV A Maintenance Bypass U SER M ANUAL Transformerless with Configurable Output Distribution.
.
i T ABLE OF CONTENT S I MPORTANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
1 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual cont ains import ant instructions tha t should be c losely follow ed during installation and maintenance of this UPS tation GXT 6kV A Maintenance Byp ass. This product is designed fo r commercial / industr ial use only .
2 GLOSSARY OF SYMBOLS Risk of electrical shock Indicates W arning or Caution foll owed by import ant instructions Request s the user to consult the manual Equipment grounding conductor On Off i.
3 GENERAL DESCRIPTION Congratulation s on you r purchase of Liebert's UPS tation GXT 6 kV A Maintenance Bypass. As with every Liebert product, we st and behind our quality .
4 Maintenance Byp ass component layout UPS input switch (SW2) Output breaker (CB1) Configurable Output Distribution Bypass availability indicator (amber) UPS input power present (amber) Bypass switch .
5 MAJOR COMPONENT S The following is a genera l description of ea ch component and it s functions. Please review this section carefully , as it will give you a better understan ding as to how the UPS tation GXT 6 kV A Maintenance Byp ass operates.
6 CABLE INST ALLATION W IRING P REP ARATION For access to terminal blocks, see diagrams on pag e 4. P OWER C ABLE I NST ALLATIO N Refer to the chart be low when selecting cable s: ! CAUTION Please read this section thoroughly before attempting to install wiring to this unit.
7 Connecting Maintenance Byp ass to UPS t ation GXT6000T - 208 12 3 4 MAINTENANCE BYP ASS GND 1 208 VA C GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 132 132 13 4 L1 L2 L1 L2 +- Input Output Ext. battery Utility input L1 L2 NOTE GMB12 models are supp lied with an attached input power cord complete with L14-30 plug.
8 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 208X 12 3 4 MAINTENANCE BYP ASS GND 1 208V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attach ed input power cord complete with L14-30 plug.
9 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 240X 12 3 4 MAINTENANCE BYP ASS GND 1 240V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attached input power cord complete with L14 -30 plug.
10 W ALL-MOUNT DIAGRAM D IAGRAM FOR A TT ACHING U NIT TO W ALL Use the following diagram, which sh ows the location and measurement s of factory-cut mounting slot s, when prepar ing to attach the GXT Maintenance Bypass to a wall. Liebert recommend s using 1/4-20 mounting scre ws.
11 HARDWIRE OUTPUT OPTION This product is intended to be inst alled by a qualified electrician only . 1. COMPLETEL Y R EMOVE ALL P OWER FROM THE FRAME. If the Ma inte nance Bypass is connected to the UPS, disconnect external battery sup ply . 2. Remove the en d cover plate to access th e terminal block (see Accessing ter minal block below).
12 OPERATING PROCEDURES S T ART-UP AND INITIALIZATION Follow these steps in or der to start up the GXT 6kV A UPS while connected to the Maintenance Byp ass. O N M AINTENANCE B YP ASS 1. Set the Maintenance Bypa ss switch (SW1) to UPS position. 2. Close (position I ) UPS Input switc h (SW2).
13 S PECIFICATIONS T ypical Tr ansfer T ime (to or from maintenance byp ass) < 6 milliseconds Input V oltage Nominal 208V AC or 240V AC T otal Current 30A max. Operating Ambient T emperature 0° to +40° C S t orage Ambie nt T em perature -20° to +60° C Dimensions, W x D x H, in (mm) 8.
.
.
The Comp any Behind the Product s With over a million installations around th e globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a c.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Liebert UPStation GXT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Liebert UPStation GXT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Liebert UPStation GXT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Liebert UPStation GXT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Liebert UPStation GXT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Liebert UPStation GXT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Liebert UPStation GXT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Liebert UPStation GXT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.