P OWER P ROTECTION 1000 VA to 3000 VA UPStation ® GX R.
2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product or replace the batteries yourself. Opening or removing the cover may expose you to dangerous voltages, even if the UPS is unplugged. There are no user - serviceable parts inside the unit.
3 15. Do not plug appliances, such as hair dryers or heaters into UPS receptacles. 16. Operate UPS only from a grounded outlet (2 wire plus ground) 120 VAC, 60/50 Hz. 17. The UPS is equipped with a grounded NEMA 5 - 15 input power plug. Do not defeat the safety purpose of this plug.
4 MAJOR INTERNAL UPS COMPONENTS Surge Suppression and EMI/RFI Filters These components provide surge protection and filter electromagnetic and radio frequency interference present in the utility line. These components enable the UPS to supply pure sinewave power to sensitive equipment.
5 Loa d Capacit y Battery Fault Normal Off Test / Rese t Lift Here t o Remove Inla y Tower-Oriente d Template Inla y GENERAL INSTALLATION GUIDELINES NOTE: Use a utility receptacle with bonded neutral and ground to prevent UPS damage. Damage due to faulty utility wiring is not covered by product warranty.
6 TOWER INSTALLATION 1. Turn the On/Off switch on the front of the unit OFF. 2. With load equipment switched OFF, plug it into the UPS output receptacles. 3. Plug UPS into a dedicated and grounded wall receptacle, properly protected by a circuit breaker or fuse.
7 Loa d Capacit y Battery Fault Normal 1 2 3 4 5 6 7 Of f Test / Rese t FRONT PANEL CONTROLS & INDICATORS 1. UPS Power Switch The UPS ON/OFF switc h controls both UPS input power as well as output power to the loads. The ”I” position signifies ON, and the ”0” position signifies OFF.
8 REAR PORTS & SWITCHES 1. Serial Communications Port This port allows remote monitoring of alarm co nditions (See next page). 2. Optional SNMP Ports The SNMP (Simple Network Management Protocol) option provides intelligent Ethernet or Token Ring network communications.
9 MONITORING & COMMUNICATIONS The UPStation® GX UPS is capable of communicating with a stand - alone computer system, LAN server, UNIX host, or termina l via an EIA standard DB - 25 female connector located on the rear of the unit. The UPS typically uses this capability to provide status and power monitoring information to the computer system.
10 ALARMS Alarms indicate faults, power outages, and UPS battery operation. The tone pattern vari es according to the alarm: On - Battery / Utility Failure Alarm - one beep every 4 seconds (greater than 2 minutes battery time remaining). Silence this alarm by depressing the ”Alarm Reset” switch for a half - second.
11 UPStation® GX Troubleshooting Guide PROBLEM REASON SOLUTION UPS unplugged. Switch UPS off, verify installation per instructions, and plug securely into utility. Low utility voltage, no utility voltage, or reversed input line and neutral conductor.
12 MAINTENANCE The UPStation® GX UPS normally requires very little maintenance. Keep the sealed, maintenance - free batteries fully charged to obtain designed life of 5 years.
13 1000 - 2100 VA GX SPECIFICATIONS Model Rating (VA/Watts) 1000 VA / 700 W 1500 VA / 1050 W 2100 VA / 1500 W INPUT Voltage 120 VAC, 2 - Wire Plus Ground Voltage Range +10%, - 20% (t ransfer to battery at – 21%) Frequency 60 Hz ±5% Current 8 Amps 12 Amps 16 Amps Power Factor Minimum .
14 3000 VA GX SPECIFICATIONS Model Rating (VA/Watts) 3000 VA / 2100 W at 240 VAC, 2600 VA / 1820 W at 208 VAC INPUT Voltage 240 VAC or 208 VAC, 3 - Wire plus Ground Voltage Range +10%, - 20% (transfer to battery at – 21%) Frequency 47 to 63 Hz Current 1 5 Amps (12 Amps RMS per phase) Power Factor Minimum .
15 LIMITED WARRANTY W e are pleased that you have purchased our UPStation® GX product to enhance the reliability of the available AC power to your sensitive electronic equipment.
16 1050 Dearborn Drive Columbus, OH 4322 9 614 - 888 - 0246 Technical Support U.S.A................................. ............................. 1 - 800 - 222 - 5877 Outside the U.S.A ............ .............................. 614 - 841 - 6755 U.K.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Liebert UPStation GX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Liebert UPStation GX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Liebert UPStation GX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Liebert UPStation GX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Liebert UPStation GX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Liebert UPStation GX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Liebert UPStation GX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Liebert UPStation GX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.