Manuale d’uso / di manutenzione del prodotto 700-2200 VA del fabbricante Liebert
Vai alla pagina of 26
P OWER P ROTECTION U SER M A NUAL English 700-2200 VA 120 V PowerSure™ Interactive R.
2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to s ervice this pr oduct yourself except to replace the battery. Opening or removing the cover may expose you to dange rous voltages, even when the AC cord is disconne cted from the electrical outlet.
3 it, or the safety ground will be re moved. Operate UPS only from a properly grounded 120 VAC outlet (2 wire plu s ground). 9. The UPS is equipped with a grounded NEMA 5-15P or L5-30P input power plug (depending upon mo del). Do not defeat the safety purpose of this plug.
4 INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSur e™ Interactive Uninterruptible Po wer System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equi pment. Upon generation, AC power is clean and stable.
5 MAJOR COMPONENTS TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) A ND EMI/RFI FILTERS These UPS components provide sur ge prot ection and filter Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). They minimize an y surges or interference present in the utilit y line and keep the se nsitive equipment protected.
6 MINI-TOWER INSTALLATION 1. Unpack the UPS carefully noting the packing method. Retain the box and packing material for possible future shipme nt. CAUTION: The UPS is heavy (see spec ificatio ns). Take proper precautio ns when lifting or moving it. 2.
7 RACKMOUNT INSTALLATION 1. Unpack the UPS carefully noting the packi ng method. Retain box and packi ng material for possibl e future shipment. CAUTION: The UPS is heavy (see s pecif ications). Take the proper precautions when lifting or moving the UPS.
8 CONTROLS AND INDICATORS On/Off Button The On/Off button controls output power to connected load(s). CAUTION: Pressing the On/Off button w hen AC utility is not present will cause the UPS to begin operating from battery. T his should not be performe d unless the UPS input is connected to a properly grounded receptacle.
9 POWERSURE™ INTERACTIVE MINI-TOWER 4 26 2 64 2 1 1 3 5 4 3 5 1 6 1 5 3 700 VA 1000 / 1400 VA 2200 VA Faul t Indi cat or Lo ad/Bat tery Lev el Indi cator s Alarm Silence/ Ba tte ry T es t Bu tt on O.
10 POWERSURE™ INTERA CTIVE RACKMOUNT 2200 Model 1 3 4 62 3 6 1 5 5 5 700-1400 Models *700 Model has detachable cord 1- Output Receptacles 2- DB-9 Interface Port 3- AC Inlet 4- Intellislot™ Communi.
11 OPERATION NORMAL MODE OPERATION During normal operation, utility power prov ides energy to the UPS. The filters and the power conditioning circuit process this power to provide computer grade po wer to connected loads. The UPS maintains the batteri es in a fully charged state.
12 BATTERY MODE OPERATION Battery mode occurs in event of extreme input conditions or complete utility failur e. The battery system along with the bi-directiona l converter generates po wer for the connected load. During battery mode an alarm soun ds every 10 seconds.
13 COMMUNICATIONS INTERFACE PORT The PowerSure™ Interactive UPS contains a standar d DB-9F recepticle loc ated on the rear of the UPS unit. Several si gnals are provided o n this port and are assign.
14 UPS INTELLIGENT COMMUNICATIONS The PowerSure™ Interactive UPS has the capabi lity to communicate inte lligently with stand alone computers, net work workstations, network servers, or UNIX hosts via the DB-9 female connector located on the rear of the UPS.
15 MINI-TOWER BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions sho uld be observed before repl acing the batteries: • Turn off and disconnect the UPS from utility po wer prior to opening the battery replacement door.
16 MINI-TOWER BATTERY REPLACEMENT 700 VA Model To Disconnect: Gentl y pull wiring away To Connect: Connect red wire to red terminal, then black wire to black terminal by pushing towards connector 1000.
17 RACKMOUNT BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions sho uld be observed before replaci ng the batteries: • Turn off and disconnect the UPS from utility po wer prior to opening the battery replacement door.
18 Figure 3 Figure 5 Figure 4 Figure 1 Figure 2 Fi g ure 6 Figure 7.
19 TROUBLESHOOTING The information below indicates var ious symptoms a user may encounter in the event the PowerSure™ Interactive UPS dev elops a problem. Use this informa tion to determine whether external factors ca use the problem and ho w to remedy the situation.
20 TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION UPS output short circuited or overloaded. Ensure UPS is off. Disc onnect all loads and ensure noth ing is lodged in output r eceptacles. Ensure loads are not de fective or shorted internally. UPS fails to start when On/Off button is pressed Internal fuse is blown, indica ting internal fault.
21 POWERSURE™ INTERACTIVE TYPICAL BATTERY DISCHARGE CURVES (Discharge times are at 25° C ambient ) 0 25 50 75 100 0 20 40 60 80 Pe rcen t Load R un Ti me (Mi ns ) 0 25 50 75 100 0 20 40 60 80 Perce.
22 AUDIBLE ALARM CONDITIONS CONDITION ALARM Battery mode (utility failure) One short beep every ten seconds; more than t wo minutes of run time remaining Low battery Two short beeps every five seconds.
23 MINI-TOWER SPECIFICATIONS Model Number PS700MT-120 PS1000MT- 120 PS1400MT-120 PS2200MT-120 Model Rating VA/W 700 / 450 1000 / 670 1400 / 950 2200 / 1600 DIMENSIONS: in (mm) Unit W x D x H 5.5 x 14.4 x 7.0 (140 x 365 x 178) 6.8 x 17.5 x 8.9 (172 x 447 x 227) 6.
24 RACKMOUNT SPECIFICATIONS Model Number PS700RM-120 PS1000RM-120 PS1400RM-120 PS2200RM-120 Model Rating VA/W 700 / 450 1000 / 670 1400 / 950 2200 / 1600 DIMENSIONS: in (mm) Unit W x D x H 19 x 18 x 5.25 (483 x 457 x 133) 19 x 18 x 5.25 (483 x 457 x 133) 19 x 18 x 5.
2 5.
1050 Dearborn Drive Columbus, OH 43229 614-888 -0246 Technical Support U.S.A...............................................................1-800-222-587 7 Outside the U.S.A ...........................................614-841-6755 U.K...................
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Liebert 700-2200 VA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Liebert 700-2200 VA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Liebert 700-2200 VA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Liebert 700-2200 VA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Liebert 700-2200 VA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Liebert 700-2200 VA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Liebert 700-2200 VA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Liebert 700-2200 VA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.