HOMEOWNER'S CARE AND OPERA TION INSTRUCTIONS OTL Report No. 116-F-36-5 B-VENT MPB-33/35/40/45 SERIES MODELS A French manual is available upon request. Order P/N 875,031CF Ce manuel d’installation est disponible en francais, simplement en faire la demande.
2 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CONGRA TULA TIONS! In selecting this Lennox B-Vent Gas Appliance you have chosen the fi nest and most dependable fi replace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fi replace.
3 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifi é pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'leau.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fi xed low and high settings, alternately , while the appliance is in operation.
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Outside Combustion Air Controls Many appliances are equipped, when installed, with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MAINTENANCE T ASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner , Logs and Controls Qualifi ed Ser vice T echnician Inspect valve and ensure it is properly operating. Check piping for leaks.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T o install the front glass enclosure panel, proceed as follows: 1. Retrieve the glass door frame. Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated fi rmly .
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Electronic Appliance Checkout T o light the burner , refer to the lighting instruc- tions on Page s 20 and 21 . Ensure the igniter lights the pilot. The pilot fl ame should engulf the fl ame sensor as shown in Figure 9.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 10 Figure 11 Figure 12 Burner Flame Appearance - Model MPB-3328 Burner Flame Appearance - Model MPB-3530 Burner Flame Appearance - Model MPB-4035 & MPB-4540 Initial Installation Considerations The packaged logs are located within the fi rebox.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Glowing Embers, Vermiculite, Decorative V olcanic Stone And Log Placement Instructions: Step 1. Separate the Glowing Embers (Rockwool) into pieces about the size of a quarter (see Figure 13) . Keep the pieces fl uffed up, not matted.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-3328 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-3530 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MPB-4035 & MPB-4540 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the center log on the burner fi rst, then place the glowing embers as shown in Fig- ure 15.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) Rocker Switch Kit Cat. No. Model No. Description 80L41 FRS Rocker Switch Kit Forced Air Blower Kits Cat.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Arch Door Kit - Polished Brass Cat. No. Model Models-Where Used 98L05 ADK33CPB MPB-3328 26M43 ADK35CMPB MPB-3530 81L35 ADK40CPB MPB-4035 81L36 ADK45CPB MPB-4540 Arch Door Kit - Brushed Stainless Steel Cat.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 ARCH DESIGN SCREEN DOOR KITS Cat. No. Model Description Where Used H0858 AD35C 35” Arch Doors, Charcoal MPB3530 H0859 AD35TI 35” Arch Doors.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Decorative Arch Screen Panel Kit Cat. No. Model Model H3593 DASPK35TI 35” Dec. Arch Screen Panel Decorative Arch Screen Panel Kit This easy t.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LIGHTING INSTRUCTIONS – SIT MILLIVOL T GAS VAL VE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly .
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L ’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. TROUBLESHOOTING GUIDE - MILLIVOL T GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ST ART CHECK • T urn Off Gas Supply. • Ensure Valve Switch Is In ON Position. • Disconnect Control Harness. • T urn On Optional Remote Switch (if applicable) • Check for proper volt- age at control harness (see insert A).
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Item # Description MPB-3328 MPB-3530 MPB-4035 MPB-4540 Part No. Qty . Part No. Qty . Part No. Qty .
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS 4 7 1 2 5 40 13 12 42 3 8 9 40/45 14 15 9 33/35 20 21 10 40/45 33/35 10 23 22 26 25 27 41 43 44 14 Located Inside (see Figur.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTES.
Printed in U.S.A. © 2005 by Lennox Hearth Products P/N 875,031M REV . A 02/2006 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il LG LENNOX MPB3328CNE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del LG LENNOX MPB3328CNE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso LG LENNOX MPB3328CNE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul LG LENNOX MPB3328CNE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il LG LENNOX MPB3328CNE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del LG LENNOX MPB3328CNE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il LG LENNOX MPB3328CNE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo LG LENNOX MPB3328CNE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.