Manuale d’uso / di manutenzione del prodotto l7742u del fabbricante Lennox International Inc.
Vai alla pagina of 15
05/09 506229−01 *2P0509* *P506229-01* E 2009 Lennox Industries Inc. Dallas, T exas, USA S T abbed user interface with touch screen interaction S Humidification measurement and control S Soft blue ba.
506229−01 05/09 Page 2 ComfortSense ® 7000 Series Model L7742U Thermost at Th e ComfortSense ® 7000 Series Model L7742U thermostat is an elec- tronic 7−day , universal, multi−stage, programmable, touch screen ther- mostat.
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 3 T ouch Screen Display A B C G I H F E D E Figure 1. T ouchscreen display Press the screen anywhere − the first press turns on the backlight.
506229−01 05/09 Page 4 Home ScreenCurrent Conditions & T emperature Settings INFORMA TION DISPLA Y AREA COOLING TUE OCT 23 1:15PM Figure 2. Home Screen The HOME screen (figure 2) displays indoor temperature and outdoor temperature if the outdoor sensor is installed.
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 5 Controlling the Heat/Cool Modes of Operation On initial power up or after an a power loss over 2 hours, the thermostat powers up at the HOME screen in the AUTO position. If it powers up after a power loss of less than 2 hours, it assumes the last mode set.
506229−01 05/09 Page 6 Controlling the Fan Operation Fan Modes If backlight is not on continuous, press the screen anywhere to turn on the backlight. Press the OPTIONS tab to access the F AN mode control. Press F AN button; repeated presses scroll through all the modes, AUT O, ON, and CIRC (circulate).
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 7 Schedule t abProgramming If backlight is not on continuous, press the screen anywhere to turn on the backlight. Press the SCHEDULE tab along the top of the screen. The display changes to programming mode (figure 4) and shows the current settings.
506229−01 05/09 Page 8 Schedule ScreenProgramming Days & Events Programming process Action Display shows... 1 Press SCHEDULE tab SCHEDULE screen 2 Press EDIT UP/DOWN arrows on right−hand side of screen; EDIT changes to CANCEL 3 Press NEXT to highlight the de- sired grouping of days Days change to match selected group, e.
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 9 Options ScreenReminders & User Settings CLEAN button [ OPTIONS T AB > [CLEAN] ] When you select the OPTIONS tab, two buttons appear near the bot- tom of the screen labeled CLEAN and ENTER.
506229−01 05/09 Page 10 Options t abUser Setting s (continued) EVENTS DAIL Y 2 OR 4 default is 4; to change, scroll to EVENTS DAIL Y 2 OR 4; press ENTER. Use arrows to change to 2; press SA V E. EVENTS DAILY 2 OR 4 DEFAULT(4) 2 VIEW CONT ACT INFO scroll to VIEW CONT ACT INFO from the user settings menu; press ENTER.
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 1 1 Options t abUser Setting s (continued) COOLING LIMIT This limits the temperature at which the thermostat may be set for cooling (default is 50º); to change to any degree between 45ºF and 90ºF , scroll to COOLING LIMIT ; press ENTER.
506229−01 05/09 Page 12 Humidification BASIC & PRECISION if set up by the installer settings for BASIC or PRECISION, this adjustment controls the relative humidity (RH) be- tween 15 and 45%. Scroll to HUMIDITY SETTINGS; press ENTER. Press the box below HUMIDIFY .
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 13 Dehumidification If your system is set up to control dehumidification, this adjustment con- trols the relative humidity (RH) between 45 and 60%. Scroll to HUMID- ITY SETTINGS; press ENTER.
506229−01 05/09 Page 14 T emporary T emperature ChangePause the Schedule T wo types of temperature changes may be made: temporary (while in the SCHEDule ON mode) or permanent (while in SCHEDule OFF).
ComfortSense t Model L7742U T ouch Screen 7−Day Programmable Thermostat Page 15 Optional Remote Outdoor Sensor The outdoor sensor (X2658) may be required, especially when using Humiditrol® EDA applications. In addition to measuring and displaying outdoor temperature, the outdoor sensor provides dew point adjust- ment and control for all models.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox International Inc. l7742u è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox International Inc. l7742u - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox International Inc. l7742u imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox International Inc. l7742u ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox International Inc. l7742u, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox International Inc. l7742u.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox International Inc. l7742u. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox International Inc. l7742u insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.