Manuale d’uso / di manutenzione del prodotto Medina Merit Series del fabbricante Lennox Hearth Products
Vai alla pagina of 24
Report No. 050-S-18b-5 INST ALLA TION AND OPERA TION MANUAL W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result.
2 Cautions and Safety FOR YOUR SAFETY do not install or operate your Medina™ gas insert without first reading and under - standing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazard - ous.
3 T able of Contents Cautions and Safety .................................................................................. 2 Orifice Size / Altitude Adjustment .................................................................. 4 Fireplace Requirements .
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice should be de-rated by 4% for ever y 1,000 feet to maintain the proper ratio of gas to air .
5 Inspection The state or local gas inspector of the side wall horizontally vented gas fuel ed equi pme nt shal l not app rove the insta lla tion unless, upon ins pect ion, the inspector obser ves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.
6 Pre-Installation Features Installation Options Residential - Vented V ertical Only Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The blower motor requires 120 V olts AC for operation.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Insert Dimensions Minimum Fireplace Cavity T op View Side View A B C D Figure 1 Figure 2 Figure 3 31-1/4”(794mm) 7-1/4” (184mm) 2-1/2” (64.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Facing and Mantel - Side View F acing and M antel c learances Note: Hearth protection to be min.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Vertical V enting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap or it can terminate inside the chimney .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Zero Clearance Fireplace Installation This insert may be installed in a masonr y or factor y built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T op Log Ports Install front logs on retainer slots. Place top log on pin. Figure 10 Figure 11 Surround Panels Installation The Medina insert surround panels are made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fireplace.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. CAUTION: Specific hearth requirements apply (see Clear - ances to Combustibles).
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions P re -l ighting c hecklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. T urn the gas control knob counter -clockwise to the "PILOT" position.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flame Color and Behavior Y our Medina™ gas insert is designed for maximum heating efficiency .
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Millivolt Control Schematic Sparker Pilot Hood ON/OFF Rocker Switch, Thermostat, or Remote Thermostat Pilot Assembly Thermocouple Piezo Igniter.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintenance and Ser vicing Maintenance Checklist The following should only be performed by a qualified service technician. CAUTION: Label all wires prior to disconnection when servicing controls.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Blower Snap Switch Blower Speed Control White Ground (Green) Black Blower Black (Hot) White (Neutral) Power Source Blower Wiring Schematic Glass Door Removal CAUTION: Do not slam or strike glass door or damage may occur .
19 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Log Set Installation on Page 10 . If there is soot in one specific location, the rockwool below this location needs to be adjusted.
20 Replacement Parts Medina™ (MED) Part Number Description H6033 Cassette Assembly , NG (if LP , also requires H5464 conversion kit) H6010 Main Burner Assembly H5922 Pilot Assembly , Convertible NG .
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fa ce / S urr o u n d Pan el Kit s (R equ ire d) - I ncl ude s B lac k F ace , S u r r ou nd and Bl ack T ri m Ca t.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES E = 31.5 ” (80 0m m) fr om T op Fac in g to Bo tt om of I nse rt F = 25.5 ” (64 8m m) fr om C ent er o f G la ss to S id e F ac in g o r Si de W al l *J = 39” (9 91m m) f rom 1 0.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Lighting Label CAUT ION : YOUR CO UNT RY G AS AP PLI ANC E MU ST ALW A YS BE O PER A TE D W ITH GLA SS DOO R IN PL ACE . STO P! Rea d th e s afe ty i nfo rma tion ab ove bef ore pr ocee din g. 1.
Printed in U.S.A. © 2007 Lennox Hearth Products P/N 775,221M REV . B 03/2008 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth Products Medina Merit Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth Products Medina Merit Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth Products Medina Merit Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth Products Medina Merit Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth Products Medina Merit Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth Products Medina Merit Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth Products Medina Merit Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth Products Medina Merit Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.