G A S F U R N A C E S G43UF MERIT ® SERIES Up−Flow E N G I N E E R I N G D A T A Bulletin No. 210394 August 2005 Supersedes December 2004 AFUE − up to 92.
G43UF / Page 2 FEA TURES CONTENTS Blower Data Pages 13−15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions Pages 9−12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exhaust Pipe V enting Information Page 7 .
G43UF / Page 3 FEA TURES HEA TING SYSTEM Lennox Duralok Plus ® Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly . Main 3-pass clamshell type heat exchanger constructed of heavy−gauge, aluminized steel.
G43UF / Page 4 FEA TURES FIL TER (NOT FURNISHED) Filter and provisions for external mounting must be field provided. OPTIONS Air Filter and Rack Kit for Side Return Air Applications (Not for use with RAB Return Air Base) W ashable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation.
G43UF / Page 5 SPECIFICA TIONS Gas Heating Performance ModelNo. G43UF −24B−045 G43UF −24B−070 G43UF −36B−070 G43UF −36C−090 G43UF −36C−090H Canada Only Input− Btuh (kW) 44,000 (12.9) 66,000 (19.3) 66,000 (19.3) 88,000 (25.8) 88,000 (25.
G43UF / Page 6 OPTIONAL ACCESSORIES − MUST BE ORDERED EXTR A B" Width Models C" Wid th Models D" Width Models FIL TER KITS 1 Air Filter and Rack Kit Horizontal (end) Size of filter − in.
G43UF / Page 7 EXHAUS T PIPE VENTING T ABLE 1 Maximum Equivalent V ent Length − One or T wo Pipe Applications Altitude V ent Size (diameter) G43UF−24B−045 G43UF−24B−070 G43UF−36B−070 G43UF−36C−090 G43UF−48C−090 2 G43UF−48C−1 10 2 G43UF−60C−1 10 3 G43UF−60D−135 () ft.
G43UF / Page 8 FIL TER AIR RESIS T ANCE For 1 Inch (25 mm) Cleanable Filter (Field Provided) cfm L/s in. w .g. Pa 0 0 0.00 0 200 95 0.01 0 400 190 0.03 5 600 285 0.04 10 800 380 0.06 15 1000 470 0.09 20 1200 565 0.12 30 1400 660 0.15 35 1600 755 0.19 45 1800 850 0.
G43UF / Page 9 DIMENSIONS − INCHES (MM) 1 Bottom Return Air Opening 1 Bottom Return Air Opening ELECTRICAL INLET (Either Side) SUPPL Y AIR OPENING AIR FLOW FRONT VIEW SIDE VIEW TOP VIEW A B 9/16 (14.
40 (1016) A UP−FLOW POSITION B G43UF / Page 10 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) 1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air (W x H): 23 x 1 1 in.
G43UF / Page 1 1 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) 37 (940) 3 (76) 71M80 1−1/2 inch (38 mm) 69M29 2 inch (51 mm) See Inst allation Instructions for specific usage. CONCENTRIC W ALL TERMINA TION APPLICA TIONS CLAMP (Furnished) 2 x 1-1/2 in.
G43UF / Page 12 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) 5 (127) 5-1/2 (140) 12 (305) Minimum ABOVE GRADE INT AKE AIR EXHAUST AIR GRADE EXHAUST AIR INT AKE AIR INSULA TION (Not Furnished) If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumula- tion or other obstructions, field fabri- cated piping must be installed.
G43UF / Page 13 BLOWER/W A TTS DA T A G43UF−24B−045 PERFORMANCE (Less Filter) External St atic Air V olume / Watt s at Different Blower Speeds External St atic Pressure High Medium−High Medium−Low Low in. w .g. Pa cfm L/s W atts cfm L/s Watt s cfm L/s W atts cfm L/s Watt s 0.
G43UF / Page 14 BLOWER/W A TTS DA T A G43UF−48C−090 PERFORMANCE (Less Filter) External St atic Air V olume / Watt s at Different Blower Speeds External St atic Pressure High Medium−High Medium−Low Low in. w .g. Pa cfm L/s W atts cfm L/s Watt s cfm L/s W atts cfm L/s Watt s 0.
G43UF / Page 15 BLOWER/W A TTS DA T A G43UF−60D−135 PERFORMANCE (Less Filter) − Single Side Return Air − Air volumes in bold require field fabricated transi- tion to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) air filter in order to maintain proper air velocity .
Visit us at www .lennox.com For the latest technical information, www .lennoxdavenet.com Contact us at 1−800−4−LENNOX NOTE − Due to Lennox’ ongoing committment to quality , S pecifications, Ratings and Dimensions subject to change without notice a nd without incurring liability .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth G43UF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth G43UF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth G43UF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth G43UF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth G43UF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth G43UF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth G43UF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth G43UF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.