neighbor’ s phone. Follow your gas suppliers instructions. • If your gas supplier cannot be reached, call the fi re department. Installation and service must be performed by a qualifi ed installer , service agency or the gas sup- plier . INST ALLA TION INSTRUCTIONS MANUAL DIRECT -VENT GAS FIREPLACE HEA TER INSERTS P/N 775,156M Rev .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1. (In Canada, the current CAN-1 B149 installation code.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 3 These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 Installations at Altitudes of 0 to 4500 feet: These appliances have been tested and approved for elevations of 0 to 4500 feet (0 to 1370 meters).
5 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Figure 1 * The Steady State Effi ciency numbers based on maximum vent confi guration. DIMENSIONS Inches (millimeters) A B C N SM.= 41 1/16” (1043 mm) & MED.= 44 1/8” (1121 mm) D SM.= 26 1/16” (662 mm) & MED.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 I E F H J K L M G A B C N D Front View Side View SPECIFICA TIONS: EDVI30 & EDVI35 T op View Figure 2 DIMENSIONS EDVI30 EDVI35 Inches (millimeters) Inches (millimeters) A 32 1/16” (814 mm) C B 24 3/16” (614 mm) N 16 7/8” (427 mm) D 40 1/4” (1022 mm)Sm.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. T op of Insert (see "C" on Fig. 3) 2 3 4 5 6 7 8 9 10 11 12 0 0 18" 17" 16" 15" 1 14" D C Figure 3 Figure 4a T a.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 IMPORT ANT NOTE: If propane is used, be aware that if the tank size is too small (i.e. under 100-lbs, if this is the only gas appliance in the dwelling. Ref. NPF A 58), there may be loss of pressure, resulting in insuffi cient fuel delivery (which can result in sooting or other malfunc- tions).
9 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Direct Vent System Components The following "Security Secure Vent TM " or "Simpson Dura-Vent" brand Collinear Direct-Vent components may be safely used with these appli- ances (see Figures 14 & 15).
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 Masonry Fireplace Installation Diagram Vertical T erm- ination Cap and Flashing. Cat. No. H0908 Liner Requirements: Vertical Height Min. = 8 ft. (2.44 M) Vertical height Max. = 40 ft. (12.2 M) See Direct Vent System Components on Page 9.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 18 illustrates two methods for connecting the gas supply. The fl ex-line method is acceptable in the U.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 12 The packaged log set, vermiculite and embers are located within the fi rebox of the insert. Installation Instructions: WARNING: IF LOGS ARE NOT IN.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8. Place the glowing embers on the burner as shown in Figure 27. One package of ember material has been included with this log set Y ou will not need to use the entire bag.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 14 3 . Place the Front Right Log and the Center Left Log onto the 2 cor - responding locating pins (each) as shown in Figure 30.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Proper Pilot Flame Appearance O N O F F P I L O T L O H I Figure 36a GAS CONTROL KNOB CONVERTIBLE HI/ LO REGUL ATOR (adju sts fl am e hei ght and .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 T able 10 Burner Flame Appearance F ACTORY AIR SHUTTER SETTING INCHES (MILLIMETERS) Models Gas T ype Air Shutter Gap Natural Gas EDVI25 Propane Natural Gas 5/16" (7.94 mm) 3/16" (4.76 mm) EDVI30 Propane 1/2" (12.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35 MODEL NO. ED VI35 MANUF A CTURED A T : Union City , TN FOR USE WITH NA TURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN. GAS SUPPL Y PRESS (“ WC) PRESS MIN.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 18 MODEL NO. ED VI25 MANUF A CTURED A T : L ynwood, CA FOR USE WITH NA TURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. NOTE: THIS PAGE LEFT BLANK INTENTIONALL Y ..
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 20 Printed in U.S.A. © Lennox Hearth Products 2003 P/N 775,156M REV . G 3/2005 Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth EDVI35 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth EDVI35 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth EDVI35 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth EDVI35 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth EDVI35, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth EDVI35.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth EDVI35. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth EDVI35 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.