Manuale d’uso / di manutenzione del prodotto Catalytic Vent-Free Wall Mounted Gas FirePlace del fabbricante Lennox Hearth
Vai alla pagina of 18
Report No. 317-S-05-5 IN ST AL LA TI ON AN D OP ER A TIO N IN ST RU CT IO NS Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not light any appliance.
2 1. 0 I MP OR T AN T SA F ET Y AN D W ARN I NG IN F OR MA T IO N W ARNINGS If th e info rma tio n in this manu al is not fol- low ed e xac tly , a fi re or exp los ion may res ult cau sin g pro per ty dama ge, pers ona l inj ury or los s o f li fe.
3 2.0 GENERAL INFORMA TION This appliance is a high efficiency , unvented, flame effect gas heater . It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology .
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE THE FOLLOWING BOXED INFORMA TION APPLIES TO REQUIRE- MENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS. Note: The following requirements reference various Massachusetts and national codes not contained in this document.
5 7.0 COMBUSTION AND VENTILA TION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventil ation air .
6 8.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bedrooms or bathrooms - or areas where large amounts of steam are likely to be generated.
7 After having selected the final mounting position of the appliance, taking into account the site requirem ents as specifie d in Section 8 of these instr uc- tions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of appliance may be secured to the wall.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Insert the wall mounting screws into the top wall plugs, taking care to leave the screws protruding approximately 3/8” from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance.
9 13.0 CHECKING THE GAS CONNECTIONS T urn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution).
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 15.0 SP ARK GAP The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually .
11 5. Secure the grill in position using two M6 screws and two no. 8 self tapping screws as shown in Figure 14 . 17.0 FITTING THE GLASS F ACIA The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing.
12 19.0 BRIEFING THE CUSTOMER W ARNING Do not add log s or orn amen ts such as pine con es, ver mic uli te or roc k woo l. Usi ng the se add ed ite ms can ca use soo tin g. All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 13 Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly internally , the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier .
14 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo spark igniter .
15 27.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly .
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Figure 22 Figure 21 29.0 POSITIONING OF FIELD REMOV ABLE P ARTS W ARNING Fai lur e to pos itio n the part s in acc orda nce with the se diag rams or fail ure to use only part s sp ecifi cal ly appr ove d wit h t his hea ter ma y re sul t i n p rop ert y da mag e o r pe rso nal inj ury .
17 30.0 NOTES.
18 Printed in U.S.A. © Lennox Hearth Products 2007 P/N 850,055M REV . A 12/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.