Solar W a ter Pumping Products Ca t alog.
SD 6 - 35 PUMP Maximum Pump V oltage: 30 V olts Maximum T otal D ynamic Head: 35 Meters (115 Feet) Flow at F ull Depth: 6.0 lpm (1.6 gpm) SD 3 - 70 PUMP Maximum Pump V oltage: 30 V olts Maximum T otal D ynamic Head: 70 Meters (230 Feet) Flow at F ull Depth: 3.
Greetings T able of Contents SD Diaphragm Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CD 300 Diaphragm Pump C ontroller . . . . . . . . . . . . . . . . . . . 3 SC Centrifugal P umps . . . . . . . . . . . . . . . . . . . . .
2 SD Diaphr agm Pumps ■ Solar W ater Pumping Products Ca t alog ■ ▼ W a ter Deliver y up to 4.5 gpm /17.0 lpm, Pumping R ange 0-230 feet / 0-70 meters Highest Quality Submersible Pump in its Cla.
CD 300 Diaphr agm Pump Controller 3 ■ Solar W ater Pumping Products Ca t alog ■ Description V alue Maximum Ambient T emperature 50° C Minimum Ambient T emperature -20° C Maximum Solar/Input V oltage (total VOC @ -20° C) 50 V olts Max. Output C urrent - Current Boost Mode (input voltage greater than output voltage) 10 Amps Max.
4 SC Centrifugal Pumps ■ Solar W ater Pumping Products Ca t alog ■ ▼ W a ter Deliver y up to 43 gpm /162 lpm, Pumping R ange 0-525 feet / 0-160 meters Brushles s, Permanent Magnet Motor with Mul.
CC 2000 Centrifugal Pump Controller 5 ■ Solar W ater Pumping Products Ca t alog ■ C C 2000 Pump C ontroller ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ F or SC Series Pumps A ccommod a tes Arr a ys with two t.
6 K y ocer a Solar Modules and Interconnects / MC Connectors ■ Solar W ater Pumping Products Ca t alog ■ Model K C125G K C120 K C80 K C70 K C60 K C50 K C40 Rated P ower ( Watts) 125.0 120.0 80.0 70.0 60.0 50.0 40.0 Current at Max. Power (Amps) 7.2 7.
Balance of System 7 ■ Solar W ater Pumping Products Ca t alog ■ T rackers ▼ ▼ P as sive tr ackers c an increase wa ter deliver y b y 50% or more A djust able single-axis p assive solar tr acker follows the sun b y hea ted liquid flowing between east and west sealed canisters Unirac T racker 200 - 2.
8 Balance of System ■ Solar W ater Pumping Products Ca t alog ■ SD 12-30 Drop Kit ▼ ▼ ▼ ▼ 3/4" Pol yethylene tube Pump cable – red, black and green color code Safety rope 3/4" NPT fit ting kit (hose barb, hose clamp, 90° elbow) 50’ T ube, 75’ 12-2 Cable .
SD 6-35/3-70 Sand Shroud ▼ ▼ ▼ ▼ ▼ ▼ Elimina tes destructive sand intrusion Easy inst alla tion incl uding retrofit Constructed of rugged PVC and Pol yethylene Reus able nylon coa ted st ainles s steel ties included Dimensions: 4.5” OD x 30.
10 SD Pump Sizing ■ Solar W ater Pumping Products Ca t alog ■ Designing a Solar Pumping System There are man y aspects of designing a solar pumping system. This guide provides the inf ormation to correctly select a pump , controller , sensors, solar array , wiring, and pipe.
SD Pump Sizing 11 ■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to provide the performance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er .
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ Canada and USA Sun Hours On Tilt (S.H.O .T .) Maps June 55 ° FS 50 ° FS 45 ° FS 40 ° FS 35 ° FS 30 ° FS 25 ° FS 20 ° FS 15 ° FS 15 ° FS 15 ° .
16 W arr anty and R eturn Informa tion ■ Solar W ater Pumping Products Ca t alog ■ W arranty T erms and Conditions W arranty P erformance Every product offered is fully guaranteed b y the manufacturer . The complete warranty detail of each product is available upon r equest.
.
7812 East Acoma Drive Scottsdale, AZ 85260 USA 480 .951.6330 F AX: 480 .951.6329 800 .544.6466 www .kyocerasolar .com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Kyocera SD 3-70 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Kyocera SD 3-70 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Kyocera SD 3-70 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Kyocera SD 3-70 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Kyocera SD 3-70, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Kyocera SD 3-70.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Kyocera SD 3-70. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Kyocera SD 3-70 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.