Process ECN-2
Technical Data and Crossover Information
©Eastman Kodak Company, 2004


Introduction KODAK VISION2 Color Negative Control Strips (Figure 1) are intended for the control of Process ECN-2 using the procedures described in KODAK Publication No. H-24, Manual for Processing KODAK Motion Picture Films, Module 1, Process Control.
The first batch of KODAK VISION2 Color Negative Control Strips is code 5011 for 35 mm, CAT 152 0469 and code 5012 for 16 mm, CAT 152 0444.
KODAK VISION2 Color Negative Control Strips, Process ECN-2, are packaged in 100-foot rolls containing at least 120 exposures and a processed reference strip. The exposures on the roll are spaced at 9.5-inch intervals. Each exposure has 21 gray-scale steps at 0.20 log H increments (2/3 camera stop).
The reference strip accompanying each roll was exposed along with all other control strips; it was then processed under specified well-controlled conditions. An instruction sheet enclosed with the package contains process deviation (correction) factors, if they are required, to determine your laboratory process aim numbers. A four-digit code number appearing on the carton, can, control strips, reference strips, and instruction sheet, identifies each production batch of strips.
KODAK VISION2 Color Negative Control Strips, Technical Data and Crossover Information 3
Steps

Control Strip Log Exposure Range The graphs in Figure 2 and Figure 3 demonstrate the differences between the former ECN control strip exposed on KODAK VISION 200T Color Negative Film 5274, and the new format exposed on KODAK VISION2 200T Color Negative Film 5217.
Physically, the center-to-center step distance has been maintained on the new control strips; no problems should be encountered with existing automatic densitometers.
Once the transition to the new control strips is complete, and the new control step reference values have been determined, continue to use KODAK VISION2 Color Negative Control Strips in the same manner as your previous control strips.
Please contact your Kodak representative for additional information on monitoring your process with control strips.

Figure 2 ECN-2 Control Strip Exposed on KODAK VISION 200T Color Negative Film 5274
1/50 sec
Densitometry:
Status M
DENSITY
-4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0
LOG EXPOSURE (lux-seconds)

Figure 3 ECN-2 Control Strip Exposed on KODAK VISION2 200T Color Negative Film 5217
DENSITY
-4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0
LOG EXPOSURE (lux-seconds)

Figures 4 through 13 illustrate some of the major photographic effects of mechanical and chemical variations on KODAK VISION2 Color Negative Control Strips exposed on 5217 Film compared to the former VISION Control Strips exposed on 5274 Film. Each plot shows the effect of a change in a process variable (horizontal axis), on the dye density of the processed film (vertical axis). These density plots are deviated against the standard level for each variable (e.g. standard level for the variable is represented by zero density).
The magnitude of the changes shown in these plots should not be considered to be process control limits. Also, the data presented are qualitative, not quantitative. The plots were derived from experiments using small laboratory machines in which all constituents were held constant except the variable being studied. Hence, the figures should be used only as trend charts and guides. If two or more process variable are changed, the resulting photographic effect illustrated may not be additive. Interactions can occur that produce effects other than those predicted by addition. The plots in this publication are representative only; they do not contain all possible solution problems. Most of the important photographic effects take place in the developer.

Figure 4 Effects of Time and Temperature Variations —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 5 Effects of pH and CD-3 Variations —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 6 Effects of NaBr and AF-2000 Variations —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 7 Effects of Na2SO3 and Under and Over Replenishment Variations —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 8 Effects of PB-C1 and PB-2 Prebath Contamination —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 9 Effects of CD-2 for CD-3 and Stop Bath Contamination —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 10 Effects of Bleach Contamination —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 11 Effects of F-34a Fixer and Final Rinse Contamination —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 12 Effects of KI Contamination and Water Dilution —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Figure 13 Effects of Bacterial Na2S and Na2CO3 Contamination —VISION2 Control Strips versus VISION Control Strips in Process ECN-2 Developer


Control-Strip Crossover Important: During the inventory crossover from the old VISION Control Strips to the new VISION2 Control Strips, every effort should be taken in your operations to avoid switching back and forth. Your process control will be greatly simplified by depleting your supply of the VISION Control Strips (except for what is needed for crossover purposes) prior to utilizing the VISION2 Control Strips.
Use the following crossover procedure each time a new code number is put into service: • Determine the aim values for the new batch, the same as you did for the current or old batch by reading the specified steps (D-min, LD, MD, and HD or D-max) of the reference strip and applying the correction factors. If there is more than one roll of the same batch, average the corresponding step densities for all reference strips in the batch, then apply the correction factors.
There will come a time when you will need to begin using a new batch of control strips. A new batch means a new code number, not a fresh box of strips with the same code number. Please be aware no two batches of control strips are identical because of slight differences in product, exposures, process, etc. And therefore, the aim value numbers will not match (however, on rare occasions they could), even with the application of the deviation factors.
When you first started using control strips, you had no previous reference and you set up your aim value parameters by reading the densities of the specified (D-min, LD, MD, HD, or D-max) control reference steps and applying the deviation numbers supplied with that batch. Using a new batch of strips is really no different, except you will have a new set of aim numbers,
As the time approaches to change to a new batch (code), you will want to make a “crossover” from the current, or old batch. Crossover simply means to adapt to a change in aim numbers, not a change in processing technique. You should begin the crossover with at least a week’s supply of strips still available (never wait until you run out).
The crossover to a new batch lets you get a “feel” for the new set of aim numbers. Do not attempt to match the new aim numbers to the old ones. If you do, you probably will find it necessary to change the mechanical and/or chemical specifications of the process, and this will most likely lead to a non-conforming unacceptable process. You will notice some differences in the way the new batch trends as compared to the previous batch. this is a normal batch-to- batch variation, and is to be expected. If you are unable to maintain a plot within your action limits with the new control-strip batch, call your Kodak representative to assist you.


10 12 11 12 11 11 11 12 10 10 12

MORE INFORMATION Outside the United States and Canada, please contact your Kodak representative.
You can also visit our web site at www.kodak.com/go/ motion for further information. You may want to bookmark our location so you can find us easily the next time.
Kodak, VISION, and VISION2 are trademarks.
KODAK VISION2 Color Negative Control Strips KODAK Publication No. V2CS
Revised 5-05 Printed in U.S.A.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.