Manuale d’uso / di manutenzione del prodotto 2006 del fabbricante Keating Of Chicago
Vai alla pagina of 43
SERIES 2006 FR YER MANUAL Keating’ s INCREDIBLE FR YING MACHINE ® READ AND SA VE THIS MANUAL FOR FUTURE REFERENCE Record the Model No. and Serial No. of this Incr edible Frying Machine ® in the space provided below . Serial No. __________________________ Model No.
POST THIS LABEL IN A PROMINENT LOCA TION ON YOUR UNIT IMPOR T ANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS A T MAIN SHUT OFF V AL VE AND CONT ACT THE LOCAL GAS COMP ANY OR GAS SUPPLIER FOR SERVICE. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINI- TY OF THIS OR ANY OTHER APPLIANCE.
INTRODUCTION Keating’s Incredible Frying Machine ® (IFM) are designed to give maximum production efficiency , deliv- ering high quality food products. The following design features are incorporated in Keating’s Incredible Frying Machine ® (IFM).
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY APPLIANCE. Y ou will post, in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained from your local gas supplier .
INST ALLA TION This fryer MUST be inst alled, inspected, calibrated and serviced by qualified and/or certified and/or licensed service personnel - you may void your Keating warranty if installation is not completed per local, national and Keating specifications.
INST ALLA TION The installer is responsible for att aching the tipping restraint. ELECTRICAL CONNECTION The Keating IFM, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, the National Electrical Code, ANSI/NFP A No.
GAS PRESSURE A T MANIFOLD NA TURAL Gas - 3.0 in. W .C. LP Gas - 10.0 in. W .C. MAXIMUM INCOMING GAS PRESSURE NA TUARAL Gas - 7.0 in. W .C. LP Gas - 1 1.0 in. W .C. NOTE: It is estimated that half of all service calls made on Keating Incredible Frying Machine® (IFM) result from an inadequate gas supply .
1. T urn on main power switch. 2. Set thermostat to desired setting. (Between 325°F/162.8°C) – (335°F/165.3°C) 3. Once main power switch is on and the thermostat is set, the following occurs: a. Blower will start and blower indicating light will come on.
STEP 2 PRESS all 3 buttons in sequence: lef t-center- right. The BEEPER will BEEP . If BEEPER does not BEEP , the timer is defective. STOP TESTING . Reset procedure is completed when 1:00 appears on the digital display . DIGIT AL TIMER (P ART # 030834) PROGRAMMING T o program the timers, the unit must be in the idle mode.
Figure 3-4 Keating Klenzer and Sea Powder 1. Put on safety attire. See Draining. 2. T urn the fryer off 3. Drain oil from fryer , see draining steps 2-4 above. 4. Remove oil container to a secure area to prevent accidental spillage. 5. Fill fryer vessel to “Max” line with water .
MAINTENANCE W ARRANTY REP AIRS Keating’s warranty begins with the date of inst allation (or ship date if we are not notified of an installation date).
Short Cycle : The thermost at will cycle rapidly while the fryer is in the idle mode; the temperature will be erratic. Thermostat Bulb Positioning 18 " & up Fryer Gas SER VICE ALL HI-LIMIT CONTROLS ARE PRESET A T THE F ACTOR Y FOR A SPECIFIC TEMPERA TURE.
SELF-HELP GUIDE 11 Common Problems Probable Cause Solutions (Follow Sequentially) 1. No power to unit. a. Power switch light ON only . b. Power Switch light and Red overmax temperature light on. c. All lights are off. a. Drain handle not locked into place.
12 Problem Probable Cause Solution Main power light does not come on. a. Fryer not plugged in. b. Breaker has tripped. c. Main power switch is faulty . a. Plug fryer into approved outlet. Must be properly grounded. b. Reset the breaker lcoated on the bottom of the control panel c.
13 Problem Probable Cause Solution Delayed ignition. a. S park electrode gap is incorrect. b. Gas pressure excessive (incoming or manifold). c. S park module intermittent. a. Set proper gap on electrode (See detail on Page 26 ). b. Set pressure to serial plate.
14 Problem Probable Cause Solution Basket-lift motor runs, but basket does not move. a. Actuator is faulty . a. Replace actuator . Basket(s) rise prematurely . a. Electronic timer is faulty . b. Basket lift relay is faulty . a. Replace timer . b. Replace relay .
ITEM MODEL P ART NO. DESCRIPTION QTY 1 14” 030862 Blower 1 18” & 20” 053726 Blower 1 052471 Insulation 2 2 054162 Air Hose 2 015393 1 / 2 " Clamp 2 3 Call 1-800-KEA TING Fry Pot 1 4 020.
Oil Return Piping Assembly (Enlarged V iew) Front V iew Side View 3 2 1 8 9* 4 5 10 7 6 15 16 17 18 13 14 Burner & Electrode Assembly See Detail on Page 23 12 11 19 20 16 INCREDIBLE FR YING MACHINE® GAS FR YER REAR DRAIN - MODEL 2000 (corresponds with part s list on page 15) * Not shown See pages 20-22 for Control Panel Part s List.
17 INCREDIBLE FR YING MACHINE® GAS FR YER P ARTS LIST - MODEL 2006 ITEM MODEL P ART NO. DESCRIPTION QTY 1 14” 030862 Blower 1 18” & 20” 053726 Blower 1 2 ALL 057996 Air Hose 1.
18 INCREDIBLE FR YING MACHINE® GAS FR YER FRONT DRAIN - MODEL 2006 (corresponds with part s list on page 17) See pages 23-25 for Control Panel Part s List.
19 INCREDIBLE FR YING MACHINE® (IFM) GAS FR YER ASSEMBL Y FRONT DRAIN (FOR REFERENCE ONL Y) HIGH LIMIT THERMOST A T FR Y POT (FRONT DRAIN SHOWN) BURNER ASSEMBL Y (SEE P AGE 17) INSULA TION.
ITEM DESCRIPTION QTY P ART NUMBER 1 Power Switch with green Light 1 032242 Power Switch without Light 1 035030 2 Indicating Light Blue 1 015120 3 Indicating Light Amber 1 021254 4 Indicating Light Gre.
ITEM DESCRIPTION QTY P ART NUMBER 1 Power Switch with green Light 1 032242 Power Switch without Light 1 035030 2 Indicating Light Blue 1 015120 3 Indicating Light Amber 1 021254 4 Indicating Light Gre.
22 IFM CONTROL P ANEL P ARTS LIST MODEL 2006 CPU ITEM DESCRIPTION QTY P ART NUMBER 1 Indicating Light Red Rectangular 28V 1 021209 2 Switch Rocker On / Off DPST 1 035030 3 Computer 1 031 125 Computer .
23 BOB EV ANS IFM CONTROL P ANEL P ARTS LIST(FRONT/REAR DRAIN - CONCEALED THERMOST A T - NO TIMERS) MODEL 2006 ITEM DESCRIPTION QTY P ART NUMBER 1 Switch T oggle Sealed On-Off 1 056056 2 Indicating Li.
24 IFM CONTROL P ANEL P ARTS LIST(FRONT DRAIN WITH TIMERS) MODEL 2006 - 14” SIZE ITEM DESCRIPTION QTY P ART NUMBER 1 Switch T oggle Sealed On-Off 1 056056 2 Indicating Light Clear Roundt 28V 1 05786.
25 IFM CONTROL P ANEL P ARTS LIST(FRONT DRAIN WITH TIMERS) MODEL 2007 - 18” & 20” SIZE ITEM DESCRIPTION QTY P ART NUMBER 1 Switch Rocker On / Off DPST 1 035030 2 Indicating Light Blue Rectangu.
26 Figure 7-2 IFM Burner Assembly (Right Side Shown) ITEM DESCRIPTION QTY P ART NUMBER 1 BURNER REPLACEMENT KIT 1 016506 (BURNER WITH ITEMS 5 & 6) 2 SP ARK ELECTRODE REPLACEMENT KIT 1 NA TURAL GAS.
27 DESCRIPTION QTY P ART # 1 TRANSFORMER 120/208/240/480V 1 056036 2* CIRCUIT BREAKER 3A/250V 1 053338 3 RELA Y DPDT 24V AC 2 030844 4 RECTIFIER 1 018321 5 POWER CORD 1 021289 6 CONNECTION 3 CIRCUITS .
28 Single Basket Lift Power Supply Box NOTES: 1. Wire Material: See wires specification 2. Remove 3/8” of insulation from end of wire 3. Route all wires so they lay flat and are organized in appearance.
29 14 IFM 120V CONNECTION DIAGRAM - NO TIMERS, FRONT DRAIN - MODEL 2000 CONTROL P ANEL INSER T CONTROL P ANEL BACK.
30 CONTROL P ANEL INSER T IFM - 120V CONNECTION DIAGRAM - TIMERS, FRONT DRAIN WITH LIGHTED ROCKER SWITCH - MODEL 2000 CONTROL P ANEL BACK.
31 14 IFM - MODEL 2006 FRONT DRAIN WITHOUT LIGHTED ROCKER SWITCH.
32 14 IFM - MODEL 2006 WITH SAFE AND EASY ® FIL TER.
33 14 IFM - MODEL 2006 CPU BASKET LIFT FRONT DRAIN.
34 18 & 20 IFM - MODEL 2006 FRONT DRAIN WITH LIGHTED ROCKER SWITCH.
35 18 & 20 IFM - MODEL 2007 FRONT DRAIN WITHOUT LIGHTED ROCKER SWITCH.
36 18 & 20 IFM - MODEL 2007 REAR DRAIN WITHOUT LIGHTED ROCKER SWITCH.
37 18 & 20 IFM - MODEL 2007 WITH SAFE AND EASY ® FIL TER WITHOUT LIGHTED ROCKER SWITCH.
38 BOB EV ANS IFM - 120V CONNECTION DIAGRAM - NO TIMERS, REAR DRAIN - MODEL 2006 WITH T OGGLE SWITCHES Effective 5/2006.
39 IFM 120V CONNECTION DIAGRAM - TIMERS, FRONT DRAIN - MODEL 2006 WITH T OGGLE SWITCHES Effective 5/2006.
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp®, Custom Pasta.
SER VICE INFORMA TION If you hav e a service related question call 1-800-KEA TING. Please state the nature of the call; it will ensure speaking with the appropriate person. Hav e your serial and model number av ailable when ordering parts. KEA TING OF CHICA GO, INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Keating Of Chicago 2006 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Keating Of Chicago 2006 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Keating Of Chicago 2006 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Keating Of Chicago 2006 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Keating Of Chicago 2006, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Keating Of Chicago 2006.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Keating Of Chicago 2006. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Keating Of Chicago 2006 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.