Manuale d’uso / di manutenzione del prodotto NetLinx Custom Panel Interface NXP-CPI16 del fabbricante AMX
Vai alla pagina of 18
Operation/Reference Guide Custom Panel I nterfaces NXP-CPI16 NetLinx Custom Panel Interface Last Rev ised: 1/13/ 2009.
AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with .
Table of Contents i NXP-CPI16 NetLinx Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ..........................
.
Produc t Info rma tion 1 NXP-CPI16 NetLinx Custom Panel Interfa ce Product Information The AMX NXP-CPI16 is a NetLinx panel device that allows sys tem integrators to connect switches, indicators, and rotary encoders to a NetLinx control system.
2 NXP-CPI16 NetLinx Custom Panel Interfa c e Specifications The table below lists the NXP-CPI1 6 specifications. NXP-CPI16 Specifications Power Requirement 12 VDC (300 m A ma x.
3 NXP-CPI16 NetLinx Custom Panel Interfa ce Input and Output Conne ctors T o install the NXP-CPI16, connect r ibbon cables or a PC b oard to one or more of the h eaders. The table belo w shows the pinouts for the two 20-pin headers. Quadrature Connectors The table below lists th e connector pinouts for the quadrature connector .
4 NXP-CPI16 NetLinx Custom Panel Interfa c e Quad ratur e Input s By default, the quadrature inputs e xpect the phase relationship, shown in FIG. 2, for a clockwise rotation of the encoder to generate a positiv e level change. If the phase relationship does not match the e xample, a clockwise rotation will generate a negati ve lev e l change.
Progra mming 5 NXP-CPI16 NetLinx Custom Panel Interfa ce Programming There are two modes of Channel A ssign ments: Discrete Outp ut and Def au lt Mode.
Send_Commands Use the Send_Commands listed in the table belo w to program the NXP-CPI16. Send_Commands BMODE Configures either set of 8 outp uts as an 8-segment bar- graph display .
7 NXP-CPI16 NetLinx Custom Panel Interfa ce Send_Commands (Cont.) LV L _ S Z Sets the size (data type) of the value that will be used by the NXP-CPI16 when receiving and sending LEVEL messages. The default is byte (8-bits), which yields a rang e of 0 - 2 55 for the level value.
8 NXP-CPI16 NetLinx Custom Panel Interfa c e The NXP-CPI16 uses input channels to rep ort user input on the contacts or switches attached to the input terminals. Output channels are used to turn on the lamp or LED display de vice s to indicate the b utton status to the user .
9 NXP-CPI16 NetLinx Custom Panel Interfa ce Each of the two 20-pin connectors is assign ed a group of 8 input and output channels. The table belo w sho ws the relation of input and output channels in the ST A TUS modes. The NXP-CPI16 may be configured to default to ST A TUS- ON mode using the follo wing method.
10 NXP-CPI16 NetLinx Custom Panel Interfa c e.
System Worksheets 11 NXP-CPI16 NetLinx Custom Panel Interfa ce System Worksheets Header 1 Header 2 Dealer ID Date Dealer PO Number Job SO Number Description Serial Number Rev Number Device Number CH1 .
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out In Out In Out In Out In Out In Out In Out In Out In 9 10 11 12 Ground Po w e r Ground Ground 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20.
.
1/09 © 2009 AM X. All right s reserved . AMX and the AMX logo ar e registered trademarks of AMX. A MX reserves t he right to alter spec ific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il AMX NetLinx Custom Panel Interface NXP-CPI16 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del AMX NetLinx Custom Panel Interface NXP-CPI16 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso AMX NetLinx Custom Panel Interface NXP-CPI16 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul AMX NetLinx Custom Panel Interface NXP-CPI16 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il AMX NetLinx Custom Panel Interface NXP-CPI16, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del AMX NetLinx Custom Panel Interface NXP-CPI16.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il AMX NetLinx Custom Panel Interface NXP-CPI16. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo AMX NetLinx Custom Panel Interface NXP-CPI16 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.