Operation/Reference Guide MAX by AMX MAX-CSE/MAX-CSD10 MAX Video Encoder & Video Decoder Last Revised: 6/19/2007.
AMX Limited Warranty and Disclaimer All products returned to AMX requ ire a Return Mate rial Authorization (RMA) number . The RMA number is obtained from the AMX RMA Department. The RMA number must be clear ly marked on the outside of each box. The RMA is valid for a 30-day period.
Table of Contents i MAX-CSE/MAX-CSD10 Operation/Reference Guide Table of Contents MAX-CSE Video Encoder ............... .............................. ....................................... 1 Overview .............................. ..................
ii MAX-CSE/MAX-CSD10 Operation/Reference Guide Table of Contents A/V Set up Page ......................... ......................... ........................ ......................... .. 32 Changing Video and Audio Settings ......... ................ .
Table of Contents iii MAX-CSE/MAX-CSD10 Operation/Reference Guide Configuration and Firmware Upda te ..................... ............................. .............. 59 Before You Begin .................. ......................... ..................
iv MAX-CSE/MAX-CSD10 Operation/Reference Guide Table of Contents.
MAX-CSE Video Enc oder 1 MAX-CSE/MAX-CSD10 Operation/Referenc e Guide MAX-CSE Video Encoder Overview The MAX-CSE (Commercial Solutions En coder) allows audio and video signals to be deli vered in real.
MAX-CSE Video Encoder 2 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Product Specifications FIG. 1 shows the front and rear vie ws of the MAX-CSE. The following table outlines the specifications for the MAX-CSE V ideo Encoder . FIG. 1 MAX-CSE Video Encoder (f ront and rear views) MAX-CSE Specifications Dimensions (HWD): 1.
MAX-CSE Video Enc oder 3 MAX-CSE/MAX-CSD10 Operation/Referenc e Guide MAX-CSE Specifications (Cont.) Supported Audio Codecs: • MPEG Audio Level 2 (MP2) • MPEG Audio Level 3 (MP3) Front Panel Components: • ID pushbutton: Used to set the NetLinx ID ( Device only ) assignment and reset the unit to factory defaults.
MAX-CSE Video Encoder 4 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Specific ations (Cont.) Rear Panel Connectors (Cont.): • I/O: T wo digital 4-channel binary I/O ports for contact closure (accepts a 4-pin 3.5mm mini-Phoenix captive-wire connecto r).
MAX-CSD10 Video Dec oder 5 MAX-CSE/MAX-CSD10 Operation/Referenc e Guide MAX-CSD10 Video Decoder Overview The MAX-CSD10 is engineered to pro vide real-time decoding of streamed digital video content ou.
MAX-CSD10 Video Decoder 6 MAX-CSE/MAX-CSD10 Operation/Reference Guide The following table outlines the specifications for the MAX-CSD10 V ideo Decoder . MAX-CSD10 (FG2178-72) Specifi cations Dimensions (HWD): 1.58" x 5.54" x 6.95" (4.01 cm x 14.
MAX-CSD10 Video Dec oder 7 MAX-CSE/MAX-CSD10 Operation/Referenc e Guide MAX-CSD10 Specifications (Cont.) • RS-232/422/485: Single 9-pin (DB9) port supports RS-232/422/485 data output including: • .
MAX-CSD10 Video Decoder 8 MAX-CSE/MAX-CSD10 Operation/Reference Guide.
MAX-CSE and MA X-CSD10 Installation 9 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE and MAX-CSD10 Installation MAX-CSE and MAX-CSD10 Connections and Wiring Port Assignments an d Functional ity T.
MAX-CSE and MAX-CSD10 Installation 10 MAX-CSE/MAX-CSD10 Operation/Reference Guide Wiring length gui delines Refer to the follo wing table for the wiring length information related to the tar get MAX unit: Preparing captive wires Y ou will need a wire stripper and flat-blade scre wdriv er to prepare and connect the captive wires.
MAX-CSE and MA X-CSD10 Installation 11 MAX-CSE/MAX-CSD10 Operation/Reference Guide PoE - Special wiri ng instructions Before beginning the connection from the PoE switch to the tar get MAX unit, follow these i n structions carefully: Refer to the procedures outlined within the pre vious Pr eparing c aptive wir es section on page 10.
MAX-CSE and MAX-CSD10 Installation 12 MAX-CSE/MAX-CSD10 Operation/Reference Guide Wiring the MAX-CSE connecto rs and cables The rear connectors on the MAX-CSE (FIG. 5) are used to input external multimedia signals and then stream them to the network/web .
MAX-CSE and MA X-CSD10 Installation 13 MAX-CSE/MAX-CSD10 Operation/Reference Guide Ethernet/RJ- 45 Port: Conn ections and Wirin g The following table lists the pinouts, signals, and pairing for the Ethernet connector . FIG. 6 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.
MAX-CSE and MAX-CSD10 Installation 14 MAX-CSE/MAX-CSD10 Operation/Reference Guide Power over Etherne t (PoE) wiring PoE can be used to indirectly provide DC power to this 802.3af-compliant device via the unuse d wire pairs in the UTP or STP Ethernet cable (RJ-45 pins 4, 5, 7, and 8).
MAX-CSE and MA X-CSD10 Installation 15 MAX-CSE/MAX-CSD10 Operation/Reference Guide The DB9 De vic e Port connector supports RS-232 co mmunication protocols for PC data transmission. This table’ s wiring specifications are applicable to the rear RS-2 32/422/485 Device Port connectors on the MAX-CSE.
MAX-CSE and MAX-CSD10 Installation 16 MAX-CSE/MAX-CSD10 Operation/Reference Guide When used for outputs, the I/O port acts as a switch to GND and is rated at 200 mA @ 12 VDC.
MAX-CSE and MA X-CSD10 Installation 17 MAX-CSE/MAX-CSD10 Operation/Reference Guide Installing Into an Equipment Rack Both the MAX-CSE Encoder and the MAX-CSD10 Decoder are designed to be tabletop units, but the y may also be fitted for use into equipment racks.
MAX-CSE and MAX-CSD10 Installation 18 MAX-CSE/MAX-CSD10 Operation/Reference Guide.
MAX-CSE Web Interface 19 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Web Interface Overview The MAX-CSE and the MAX-CSD10 incorporate built-in security ve rification capabilities.
MAX-CSE Web Interface 20 MAX-CSE/MAX-CSD10 Operation/Reference Guide There is no limit to the number of co ncurrent logins allo wed on the ta rget MAX unit.
MAX-CSE Web Interface 21 MAX-CSE/MAX-CSD10 Operation/Reference Guide Browser-based UI Application Overview The UI web page (FIG. 13) can be divided into separate sections or frames, some of which are independent of the curre nt selection and can both display their o w n information and contain their own functionality .
MAX-CSE Web Interface 22 MAX-CSE/MAX-CSD10 Operation/Reference Guide Administrat ion Page Features (C ont.) F eature Description • IP Settings This button launches the IP Settings page, which provides the user with the abil- ity to assign the method of commun ication used by the target MAX unit, along with its associated IP parameters.
MAX-CSE Web Interface 23 MAX-CSE/MAX-CSD10 Operation/Reference Guide Administration Page The Administration page (FIG. 14) is the first page displayed in the Acti ve frame after a su ccessful login. It can also be accessed by clicking on the Admin button in the Navigation Bar .
MAX-CSE Web Interface 24 MAX-CSE/MAX-CSD10 Operation/Reference Guide Changing the Program Description 1. From the Administration page, enter ne w information in the Pr ogram N ame , Pr ogram Description , Information URL , E-Mail , and Phone Number fields.
MAX-CSE Web Interface 25 MAX-CSE/MAX-CSD10 Operation/Reference Guide Upgrading New Firmware The UI presents the following dialog to remind you that the de vice must be rebooted before new firmw are can be loaded (FIG. 15). Before you upload any f i rmware f ile, you MUST re boot this de vice: a.
MAX-CSE Web Interface 26 MAX-CSE/MAX-CSD10 Operation/Reference Guide Stream Profiles Page The Str eam Pr ofiles page (FIG. 16) is accessed by clicking on the Stream Set-Up button in the Navig ation Bar .
MAX-CSE Web Interface 27 MAX-CSE/MAX-CSD10 Operation/Reference Guide In a UDP stream, only a T arget (video) Port is needed since both the audio and video information are transported together to the same port on the destination device.
MAX-CSE Web Interface 28 MAX-CSE/MAX-CSD10 Operation/Reference Guide Stream Profiles Page Features (Co nt.) F eature Description • Video In Rate A drop-down list of data rates which al lows the user to choose the amount of incoming video data throughput available for use by the MAX-CSE.
MAX-CSE Web Interface 29 MAX-CSE/MAX-CSD10 Operation/Reference Guide Stream Profiles Page Features (Co nt.) F eature Description • Sampling Rate A drop-down list from which the user can choose the sampling rate used on the audio source.
MAX-CSE Web Interface 30 MAX-CSE/MAX-CSD10 Operation/Reference Guide These profiles take effect on the MAX-CSE only after pressing the on-screen Apply b utton. Stream Profiles Page Features (Co nt.) F eature Description • T arget Address The IP Address of the target IP-c apable device that will receive the encoded outgoing media stream.
MAX-CSE Web Interface 31 MAX-CSE/MAX-CSD10 Operation/Reference Guide If a stream is currently in effect while these parameters are altered, clicking the A pply button will cause the outgoing stream to stop and then incorporat e the ne w settings without restarting.
MAX-CSE Web Interface 32 MAX-CSE/MAX-CSD10 Operation/Reference Guide A/V Set up Page The A/V Set up page (FIG. 17) is accessed by clicking on the A udio/Video b utton in the Navigation Bar . This page allows a user (with the pro per access righ ts) to configure the properties associated with both the incoming video and audio content.
MAX-CSE Web Interface 33 MAX-CSE/MAX-CSD10 Operation/Reference Guide Changing Video and Audio Settings 1. From the A/V Setup page, select from Composite or S-V ideo from the Vi d e o I n radio buttons. 2. Select from NTSC or P AL fro m the V ideo P ort radio buttons.
MAX-CSE Web Interface 34 MAX-CSE/MAX-CSD10 Operation/Reference Guide The following table lists the NetLinx Settings page features that an administr ator or oth er authorized user can configure.
MAX-CSE Web Interface 35 MAX-CSE/MAX-CSD10 Operation/Reference Guide Changing the NetLi nx Master Connection 1. From the NetLinx Settings page, select between Listen , Aut o , and URL in the Mode drop-down menu. 2. If you selected Aut o as your Mode, enter the new system number in the System Number f ield, if necessary .
MAX-CSE Web Interface 36 MAX-CSE/MAX-CSD10 Operation/Reference Guide The following table lists the IP Settings page features that an ad ministrator or other authorized user can configure. Changing the IP Settings 1. From the IP Settings page and in the IP Address section, select between Dynamic and Static on the IP radio button.
MAX-CSE Web Interface 37 MAX-CSE/MAX-CSD10 Operation/Reference Guide User Page The User page (FIG. 21) is accessed b y clicking on the User button in the Na vigation Bar . This page allows a user (with the proper access rights) to change the current acc ess Username/Password information required for UI access.
MAX-CSE Web Interface 38 MAX-CSE/MAX-CSD10 Operation/Reference Guide Changing User S ettings 1. From the User page, enter the new username in the New Username fie ld . 2. Enter your new password in the New P assword f ield. Enter it again in the Re-type P assword fiel d to verify it.
MAX-CSD10 Web Interface 39 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD10 Web Interface The bro w ser-based UI for the MAX-CSD10 Decoder , known as the Decoder Manager (FIG. 22), is significantly dif ferent from th e interface for the MAX-CSE Encoder .
MAX-CSD10 Web Interface 40 MAX-CSE/MAX-CSD10 Operation/Reference Guide Administrat ion Page Features (C ont.) F eature Description Stream St atus frame: Located on the upper-right side of the browser .
MAX-CSD10 Web Interface 41 MAX-CSE/MAX-CSD10 Operation/Reference Guide Communicating With The Unit Via the Browser-based UI T o facilitate communicate with the MAX-CSD10, it is necessary for the unit to first obtain a D HCP Address (page 49).
MAX-CSD10 Web Interface 42 MAX-CSE/MAX-CSD10 Operation/Reference Guide Stream Selector Page The Str eam Selector page (FIG. 23) allows the user to select the data stream being processed in SAP session by the MAX-CSD10. This page lists both a ll of the av ailable data streams and the stream currently being accessed.
MAX-CSD10 Web Interface 43 MAX-CSE/MAX-CSD10 Operation/Reference Guide Stream Set-up Page The Str eam Se t-up page (FIG. 24) allows you to control the stream configuration, including the mode used and the individual server being accessed.
MAX-CSD10 Web Interface 44 MAX-CSE/MAX-CSD10 Operation/Reference Guide Changing the stream confi guration At this time, the Stream Set-u p page supports three modes for data streams: SAP RSTP Manual Each mode has different procedures for setting up the stream conf iguration, as detailed below .
MAX-CSD10 Web Interface 45 MAX-CSE/MAX-CSD10 Operation/Reference Guide Setting up a Manual stream configuration 1. From the Str eam Set-up page, c hoose Manual from the Run Mode drop-down menu. (See FIG. 26.) 2. Select between UDP and R TP in the T ransports drop-down menu.
MAX-CSD10 Web Interface 46 MAX-CSE/MAX-CSD10 Operation/Reference Guide Audio/Video Page The Audio/V ideo page (FIG. 27) allows the user to set up the video po rt used by the MAX-CSD10. T o change the A/V se tup: 1. From the Audio/V ideo page, select the video port to be used by the MA X-CSD10.
MAX-CSD10 Web Interface 47 MAX-CSE/MAX-CSD10 Operation/Reference Guide T o change NetLinx settings fo r the MAX-CSD10: 1. From the NetLinx page, select the Connection Mode to be used from the drop-down menu. 2. If you selected Au to from the Connection Mode drop-down menu, enter the new System Number , if applicable.
MAX-CSD10 Web Interface 48 MAX-CSE/MAX-CSD10 Operation/Reference Guide 1. From the IP Settings page and in the IP Addr ess section , select whether the IP will be dynamic or static. 2. If you selected the IP to be static, change the information in the IP Addr ess field, if necessary .
Configuring Communication 49 MAX-CSE/MAX-CSD10 Operation/Reference Guide Configuring Communication This section refers to steps n ecessary to both communicate an d upgrade components for the MAX-CSE and MAX-CSD10. Both MAX units are conf igured to be used as standalone units running on a network capable of supporting the up to a 6Mbps data rate.
Configuring Communication 50 MAX-CSE/MAX-CSD10 Operation/Reference Guide Configuring the MAX Co mmunication Parameters Although the unit is initially configured to obtain the f irst av ailab le DHCP Address, it is recommended that after the initial connection, the unit be setup to us e a Static IP Address.
Configuring Communication 51 MAX-CSE/MAX-CSD10 Operation/Reference Guide 6. Click OK to enter the information and proceed to the f irst UI page. Assigning a Static IP Address to the MAX-CSE via the br.
Configuring Communication 52 MAX-CSE/MAX-CSD10 Operation/Reference Guide 11. The next step in the communication process is to prepare a NetLinx Master for communication to the target MAX unit. Refer to the fo llowing se ctions for detailed Master communication setup instructions.
Configuring Communication 53 MAX-CSE/MAX-CSD10 Operation/Reference Guide 12. Click OK to return to the Communications Settings dialog and place a c heckmark within the Authentication Requir ed radio box if your Master has been previously secured with a use rname/ password.
Configuring Communication 54 MAX-CSE/MAX-CSD10 Operation/Reference Guide Associating the MAX unit to a Target Master Although the MAX-CSE and MAX-CSD10 un its can function independe ntly of a NetLinx .
Configuring Communication 55 MAX-CSE/MAX-CSD10 Operation/Reference Guide Y ou must use a value which is not currently being used by another de vice currently communicating with the target Master .
Configuring Communication 56 MAX-CSE/MAX-CSD10 Operation/Reference Guide Associating a MAX-CSD1 0 Unit to a Target Master 1. From the Decoder Manager, click the NetLinx link to open the Netlinx Master page. 2. In the Connection Mode drop-down menu, select URL .
Configuring Communication 57 MAX-CSE/MAX-CSD10 Operation/Reference Guide 8. On the target Master , click Reboot ( fr om the T ools > Reboot the Master Contr oller dialog ) and w a it for the System Master to reboot. The S T A TUS and OUTPUT LEDs sho uld be gin to alternately blink during the incorporation.
Configuring Communication 58 MAX-CSE/MAX-CSD10 Operation/Reference Guide This action causes a pre viously red *Not Active* field to no w display a green W aiting...Pr ess Cancel to Quit. fie l d . This green f ield indicates that Studio is waiting to detect the de vice value of the MAX associated with the ID b utton.
Configuration and Firmware Upd ate 59 MAX-CSE/MAX-CSD10 Operation/Reference Guide Configuration and Firmware Update This section refers to steps n ecessary to both communicate an d upgrade the components for both a MAX-CSE and MAX-CSD10 unit. Before You Begin 1.
Configuration and Firmware Updat e 60 MAX-CSE/MAX-CSD10 Operation/Reference Guide Verifying the MAX’s current vers ion of Firmware - v ia Studio 1. After Studio has establish a connection to the target Master , click on the OnLine T ree tab in the W orkspace window to vie w the devices on the System.
Configuration and Firmware Upd ate 61 MAX-CSE/MAX-CSD10 Operation/Reference Guide 6. Press the Submit button to begin the process of uploading and incorporating the new firmware component to the target MAX unit.
Configuration and Firmware Updat e 62 MAX-CSE/MAX-CSD10 Operation/Reference Guide 11. Click the Reboot Device checkbox to reboot the MAX unit after the firmw are upda te process is complete. 12. Click Send to begin the transfer . The file transfer progress is indicated on the bottom-right of the dialog (FIG.
Displaying Stream Content 63 MAX-CSE/MAX-CSD10 Operation/Reference Guide Displaying Stream Content Overview The MAX-CSE Media Encoder ca n currently stream A/V signals and direct them to IP-enabled devices capable of interpreting and displaying the incoming MPEG data using either R TP or UDP Transport Protocols.
Displaying Stream Content 64 MAX-CSE/MAX-CSD10 Operation/Reference Guide media content. If the network can only handle a throughput of 4 Mbps from the encoder , it is recommended that you use something less than or equal to the High Quality encoder profile.
Displaying Stream Content 65 MAX-CSE/MAX-CSD10 Operation/Reference Guide Configuring the MAX- CSE for commun ication 1. Complete the procedures outlined within the Configuring the MAX Communication Pa r a m e t e r s section on page 50 to establish an acti ve connection to the source MAX-CSE.
Displaying Stream Content 66 MAX-CSE/MAX-CSD10 Operation/Reference Guide 8. From the Pr ofile field, click on the drop-do wn arrow and from the av ailable list, choose the desired encoder setting which conforms to the a vailable data throughput on your network.
Displaying Stream Content 67 MAX-CSE/MAX-CSD10 Operation/Reference Guide 12. Enter a numeric v alue into the Ta r g e t P o r t field. This field corresponds to the port on the destination device to which the outgoing video ( audio/video ) stream is be ing directed.
Displaying Stream Content 68 MAX-CSE/MAX-CSD10 Operation/Reference Guide 4. If you are feeding a microphone audio signal into the rear MAX-CSE microphone connector, you could use the Micr ophone Gain field to enter an audio lev el (0 - 99) assoc iated with the gain used by the rear microphone input.
Displaying Stream Content 69 MAX-CSE/MAX-CSD10 Operation/Reference Guide Our example uses: udp://192.199.99.99:5000 Refer to Configuring the MAX-CSE fo r communication sec tion on page 65. The MAX-CSE is av ailable from either the front LCD (FIG.
Displaying Stream Content 70 MAX-CSE/MAX-CSD10 Operation/Reference Guide 14. Create buttons on both this project’ s main page and within this V ideo page which can allow the user to navig ate between both pages. 15. Sav e these pages, and after establishing a connection, upload this project to the target Modero panel.
Displaying Stream Content 71 MAX-CSE/MAX-CSD10 Operation/Reference Guide If there is no signal displayed, return to the MAX-CSE UI pages and from the Encoder Profiles page, conf irm that the correct panel IP Address and target port where entered into the Str eaming Source f ield within the TPDe sign4 project.
Displaying Stream Content 72 MAX-CSE/MAX-CSD10 Operation/Reference Guide For the purposes of these proce dures, we are not required to enter a T arget Audio Port v alue because the A/V content is not begin streamed separately . 6. Click the Apply b utton to sav e the encoding profiles to the MAX-CSE.
Displaying Stream Content 73 MAX-CSE/MAX-CSD10 Operation/Reference Guide that the unit is detecting an incoming signal (sho wn by the word SYNC appearing in the V ideo Sync section of the UI). The most common error found is when a bad cable is not detected and therefore no signal is av ailable for the unit to encode.
Displaying Stream Content 74 MAX-CSE/MAX-CSD10 Operation/Reference Guide.
NetLinx Programming 75 MAX-CSE/MAX-CSD10 Operation/Reference Guide NetLinx Programming Y ou can program the MAX unit by using the commands in this sectio n to perform a wide v ariety of operations using Send_Commands and variable text commands.
NetLinx Programming 76 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE: Streaming Commands (Port 1) The streaming system on the MAX-CSE is located at Por t 1 in NetLinx D:P:S nomenclature. The MAX-CSE supports the following streaming commands. For programming purp oses, do not use a hyphen when specifying MPEG functionality .
NetLinx Programming 77 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description GET FORMA T Get a description of the format used by the current incoming video signal. Syntax: SEND_COMMAND <DEV>,"'GET FORMAT'" V ariable: format = NTSC or P AL.
NetLinx Programming 78 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description GET SESSION INFO Retrieves the selected ses- sion details. Session information is extract ed from the SAP Listener or RTSP depending on system configuration.
NetLinx Programming 79 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description GET URL Get a description of the URL parameters being used by the current audio/video stream. Requests the current configuration of the URL communica tion parameters.
NetLinx Programming 80 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description GET VSOURCE Get a description of the source type used by t he current video stream. Requests the a description of the current video source type.
NetLinx Programming 81 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description SET FORMA T Set the video format of the incoming video signal. Syntax: SEND_COMMAND <DEV>,"'SET FORMAT'" V ariable: format = NTSC or P AL.
NetLinx Programming 82 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSE Streaming Send_Commands (Cont.) Command Description SET URL Set the URL parameters for the current audio/video stream. The communication parameters must include: communication protocol, IP Address, and port used.
NetLinx Programming 83 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD: Streaming Commands (Port 1) The streaming system on the MAX-CSE is located at Port 1 in NetLinx D:P:S nomenclature. The MAX-CSE supports the following streaming commands. MAX-CSE Streaming Send_Commands (Cont.
NetLinx Programming 84 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD Streaming Send_Commands (Cont.) Command Description GET CONTROL MODE Gets the control mode of the stream.
NetLinx Programming 85 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD Streaming Send_Commands (Cont.) Command Description GET SESSION INFO This command will retrieve the selected session details. Session information is extract ed from the SAP Listener or RTSP depending on system configuration.
NetLinx Programming 86 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD Streaming Send_Commands (Cont.) Command Description GET URL Get a description of the URL parameters being used by the current audio/video stream. Requests the current configuration of the URL communica tion parameters.
NetLinx Programming 87 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD Streaming Send_Commands (Cont.) Command Description SET CONTROL MODE Set the control mode of the stream. 'MANUAL' mode lets the user to specif y all parameters such as video decoder , audio decoder , transport type, and video and audio po rts.
NetLinx Programming 88 MAX-CSE/MAX-CSD10 Operation/Reference Guide MAX-CSD Streaming Send_Commands (Cont.) Command Description SET SAP IP AL T Set the SAP Listener IP Alter- native multicast address.
NetLinx Programming 89 MAX-CSE/MAX-CSD10 Operation/Reference Guide RS-232/422/485 Send_Commands (Port 2) The serial port is located at Port 2 in NetLinx D:P:S nomenclature. The serial port supports the following commands and escape sequences. In these e xamples: <DEV> = device.
NetLinx Programming 90 MAX-CSE/MAX-CSD10 Operation/Reference Guide RS-232/422/485 Send_C ommands (Cont.) Command Description CHARDM Set the delay time between all transmitted characters to the value specified (in 1 Millisecond increments). Syntax: SEND_COMMAND <DEV>,"'CHARDM-<time>'" Va r i a b l e : time = 0 - 255.
NetLinx Programming 91 MAX-CSE/MAX-CSD10 Operation/Reference Guide RS-232/422/485 Send_C ommands (Cont.) Command Description RXOFF Disable the transmission of incoming received characters to the Master (default).
NetLinx Programming 92 MAX-CSE/MAX-CSD10 Operation/Reference Guide RS232/422/485 Ports Channels RS232/422/485 ports are Por t 2 on the MAX-CSE. RS-232/422/485 Send_C ommands (Cont.) Command Description TXCLR S top and clear all characters waiting in the transmit out buffer and stops transmission.
NetLinx Programming 93 MAX-CSE/MAX-CSD10 Operation/Reference Guide RS-232/422/485 Send_String Escape Sequences (Port 2) This device also has some special SEND_STRING escape sequen ces: If any of the 3.
NetLinx Programming 94 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR / Serial Ports Channels IR/Serial Port (Port 3) Commands The IR port is located at Por t 3 in NetLinx D:P:S nomenclature. The following IR and IR/Serial Send_Commands generate control signals for external equipment.
NetLinx Programming 95 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR/Serial Send_Commands (Cont.) Command Description CP Halt and Clear all active or buffered IR commands, and then send a single IR pulse. Y ou ca n set the Pulse and Wait times with the 'CTON' and 'CT O F' commands.
NetLinx Programming 96 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR/Serial Send_Commands (Cont.) Command Description IROFF Halt and Clear all active or buffered IR commands being output on the designated port.
NetLinx Programming 97 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR/Serial Send_Commands (Cont.) Command Description PTOF Set the time duration between power pulses in .
NetLinx Programming 98 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR/Serial Send_Commands (Cont.) Command Description SET MODE Set the IR/Serial ports for IR or Serial-controlled devices connected to a CardFrame or NetModule. Sets an IR port to either IR, Serial, or Data mode.
NetLinx Programming 99 MAX-CSE/MAX-CSD10 Operation/Reference Guide IR/Serial Send_Commands (Cont.) Command Description XCHM Changes the IR output pat- tern for the 'XCH' send command. Syntax: SEND_COMMAND <DEV>,"'XCHM <extended channel mode>'" Va r i a b l e : extended channel mode = 0 - 4.
NetLinx Programming 100 MAX-CSE/MAX-CSD10 Operation/Reference Guide I/O Port Commands (Port 4) The I/O port is located at Por t 4 in NetLinx D:P:S nomenclature.
NetLinx Programming 101 MAX-CSE/MAX-CSD10 Operation/Reference Guide LCD Commands (Port 6) The LCD is located on the front of the unit at Por t 6 in NetLinx D:P:S nomenclature. The LCD port supports the following commands. I/O Send Commands Command Description BACKLIGHT Set the LCD backlight level.
NetLinx Programming 102 MAX-CSE/MAX-CSD10 Operation/Reference Guide.
Programming 103 M AX-CSE/MAX-CSD10 Operation/Reference Guide.
6/07 © 2007 AMX. Al l rights reserved. AMX and the AMX logo are register ed trademarks of AMX. AMX reserv es the right to alter specifica tions without notice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il AMX MAX-CSD 10 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del AMX MAX-CSD 10 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso AMX MAX-CSD 10 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul AMX MAX-CSD 10 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il AMX MAX-CSD 10, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del AMX MAX-CSD 10.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il AMX MAX-CSD 10. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo AMX MAX-CSD 10 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.